ChipFind - документация

Электронный компонент: A1612B

Скачать:  PDF   ZIP

Document Outline

10209-Type 1:1 Redundancy Switch Units
Data Sheet, Rev. 1
September 2001
Features
s
50
or 75
s
10 MHz to 18 GHz
s
BNC, Type F, and SMA interface
s
Remote status monitoring
s
Remote control
s
Automatic control
Applications
s
1:1 redundancy
s
Site diversity
Description
The 10209-type redundancy switch plug-in modules
are designed to protect systems against laser, photo-
diode, or fiber failure. The modules can be configured
according to application requirements, as indicated in
the block diagrams below. In the conventional 1:1
redundancy scenario, the RF output is split and sent
to two separate transmitter and receiver links sup-
ported by a 10209 switch. In site-diversity applica-
tions, the optical output is split so that it can be sent
over two separate fiber links and then fed into the
10209 switch
.
Block Diagram
Figure 1. 10209-Type Redundancy Switch Unit
Application Configurations
RF
SPLITTER
RF
SPLITTER
IN CO M ING
RF
SIG N AL
FIBER
T x
FIBER
T x
FIBER
Rx
FIBER
Rx
PR IM AR Y
FIBER
BAC KU P
FIBER
RF
O U TG O IN G
RF
SIG NA L
RF
10209
R SU
1:1 R EDU N DAN CY C O NF IG UR AT IO N
IN CO M ING
RF
SIG N AL
FIBER
Rx
FIBER
Rx
PR IM AR Y
FIBER
BAC KU P
FIBER
RF
O U TG O IN G
RF
SIG NA L
RF
10209
R SU
SITE DIVER SITY
FIBE R
Tx
O PTIC AL
SP LITTER
1-1272F
2
Agere Systems Inc.
Data Sheet, Rev. 1
10209-Type 1:1 Redundancy Switch Units
September 2001
Absolute Maximum Ratings
Stresses in excess of the absolute maximum ratings can cause permanent damage to the device. These are abso-
lute stress ratings only. Functional operation of the device is not implied at these or any other conditions in excess
of those given in the operational sections of the data sheet. Exposure to absolute maximum ratings for extended
periods can adversely affect device reliability.
Electrical/Optical Characteristics
Parameter
Symbol
Min
Max
Unit
Operating Temperature Range
T
OP
0
50
C
Storage Temperature Range
Tstg
20
65
C
Humidity
--
--
95 noncondensing
%
Table 1. Electrical and Optical Characteristics (10209A/C/E)
Parameter
Symbol
Condition
Min
Typ
Max
Unit
Frequency Range:
10209A/C/E
10209A/C
10209E
F
--
10
--
--
--
--
--
--
2300
18000
MHz
MHz
MHz
Impedance:
10209A/C
10209E
Z
--
--
--
--
--
75
50
Insertion Loss:
Plug-in and Cables:
10209A/C
10209E
Plug-in Only:
10209A/C
10209E
L
INS
Over Any 40 MHz
--
--
--
--
1.0
1.5
0.5
0.6
1.5
2.0
--
--
dB
dB
dB
dB
Flatness:
Plug-in and Cables:
10209A/C
10209E
Plug-in Only:
10209A/C
10209E
--
Over Any 40 MHz
--
--
--
--
0.20
0.25
0.04
0.06
0.25
0.50
--
--
dB
dB
dB
dB
Flatness:
Plug-in and Cables:
10209A/C
10209E
Plug-in Only:
10209A/C
10209E
--
Over Any 500 MHz
--
--
--
--
0.25
0.30
0.05
0.08
0.50
0.60
--
--
dB
dB
dB
dB
VSVR:
10209A/C
10209E
--
All Ports, with Switch in
Corresponding Position
<1.8:1
<2.0:1
--
--
--
--
--
--
Switch Speed
--
--
--
--
25
ms
Port-to-Port Isolation
ISO
--
--
>50
>65
dB
Drive Voltage Range
V
DRIVE
Pin 1, Supplied by Chassis
and Power Supply
15
--
24
Vdc
3
Agere Systems Inc.
Data Sheet, Rev. 1
September 2001
10209-Type 1:1 Redundancy Switch Units
Pin Information
1. The pin numbers above are based on the numbers on the chassis backplane. Some connector vendors switch the order of the numbers, so if
in doubt when wiring the connectors, use the number on the Agere Systems chassis.
2. Open position available for the user.
Drive Current
I
DRIVE
Steady State
--
45
60
mA
Drive Current
10209A/C/E
10209A/C
10209E
I
DRIVE
Peak When Switching
--
--
--
--
190
218
300
--
--
mA
mA
mA
Table 2. dc Interface Pin Descriptions
Plug-in Unit,
9-pin D-sub
Connector
Corresponding
5-pin
Molex
1
Connector
10209-Type Redundancy Switch Unit
1
--
+V
CC
2
--
NC
3
--
NC
4
--
Power Ground
5
1
Reference Ground
6
2
Input: Low Optical Power Alarm, Primary
7
3
Input: Low Optical Power Alarm, Backup
8
4
Input
2
: RF Position Control,
If In Manual and Remote
(Primary = 0 V or Open Backup = 5 V)
9
5
Output
3
: Position of RF switch
Table 3. Chassis Interface
Backplane
Connector
Mating Connector
Crimp Pins
P11-P18
Molex
P/N 22-01-2057
Molex
P/N 08-50-0114
P19
Molex
P/N 22-01-2097
Molex
P/N 08-50-0114
P20
Molex
P/N 09-50-3031
Molex
P/N 08-50-0108
Table 1. Electrical and Optical Characteristics (10209A/C/E) (continued)
Parameter
Symbol
Condition
Min
Typ
Max
Unit
Electrical/Optical Characteristics
(continued)
Data Sheet, Rev. 1
10209-Type 1:1 Redundancy Switch Units
September 2001
Agere Systems Inc. reserves the right to make changes to the product(s) or information contained herein without notice. No liability is assumed as a result of their use or application.
Copyright 2001 Agere Systems Inc.
All Rights Reserved
September 2001
DS00-300OPTO-1 (Replaces DS00-300OPTO)
For additional information, contact your Agere Systems Account Manager or the following:
INTERNET:
http://www.agere.com
E-MAIL:
docmaster@agere.com
N. AMERICA:
Agere Systems Inc., 555 Union Boulevard, Room 30L-15P-BA, Allentown, PA 18109-3286
1-800-372-2447, FAX 610-712-4106 (In CANADA: 1-800-553-2448, FAX 610-712-4106)
ASIA:
Agere Systems Hong Kong Ltd., Suites 3201 & 3210-12, 32/F, Tower 2, The Gateway, Harbour City, Kowloon
Tel. (852) 3129-2000, FAX (852) 3129-2020
CHINA: (86) 21-5047-1212 (Shanghai), (86) 10-6522-5566 (Beijing), (86) 755-695-7224 (Shenzhen)
JAPAN: (81) 3-5421-1600 (Tokyo), KOREA: (82) 2-767-1850 (Seoul), SINGAPORE: (65) 778-8833, TAIWAN: (886) 2-2725-5858 (Taipei)
EUROPE:
Tel. (44) 7000 624624, FAX (44) 1344 488 045
Outline Drawings
Dimensions are in inches and (millimeters).
Ordering Information
For ordering information, please contact an account manager at Agere Systems Inc., Opto West, 1-800-362-3891
(for sales staff, please press option 2).
POWER
ON
OPTICAL
POWER
9.12 (232)
5.06
(129)
1.39
(35)
10457A
FIBER-OPTIC
RECEIVER
10 MHz--200 MHz
FRONT
PANEL
RF
OPTICAL
1-1189(F)
Molex