ChipFind - документация

Электронный компонент: SDA005-12

Скачать:  PDF   ZIP

Document Outline

SDA SERIES
Single Output, AC/DC Module
Features:
Meets UL1950, CSA C22.2 No. 234, Dentori, FCC
Class B, VCCI No.2 for conducted noise
Miniature Size, 43mm x 50mm x 19mm
Light Weight, 67g
Input AC100V~AC120V
5W and 10W with 5V and 12V outputs
Natural Convection
RCC topology
Available to apply directly to substrate
Sanken/Allegro 3100 Tower Blvd. 5
th
Fl. University Tower, Durham, NC 27707 Phone: (888)888-4914 Fax: (919)402-8540
E-mail: allegro@intrex.net
Rating
5 W
10 W
Item
Conditions
SDA005-05
SDA005-12
SDA010-05
SDA010-12
Rated Input Voltage
AC100-120V
Input Voltage Range
AC85~132V
Input Current
Rated input/output conditions
0.15A(typ)
0.26A(typ)
Inrush Current
30A (max)
25A(max)
Rated Frequency Range
50/60Hz (Frequency Range 47~440Hz)
Input
Efficiency(typ)
Rated input/output conditions
72%
76%
72%
76%
Rated Output Voltage
+5V
+12V
+5V
+12V
Adjustable Output Voltage Range
Fixed
Rated Output Current
1.0A
0.45A
2.0A
0.9A
Adjustable Output Current Range
0~1.0A
0~0.45A
0~2.0A
0~0.9A
Maximum Output Power
5W
5.4W
10W
10.8W
Ripple
Noise(mVp-p)
Rated input/output condition
120
150
120
150
O
u
t
put
Constant Voltage Accuracy
5%
Leakage Current
Rated input/output
conditions
0.5mA
Startup Time
20ms (typ)
100ms (typ)
20ms (typ)
100ms (typ)
Switching Method, Transformer Frequency
RCC topology, approx. 100kHz (under rated input/output conditions)
Oth
e
r
Output Holdup
Time
Rated input/output
conditions
10ms (typ)
Over Current Protection
Detection above approx. 120% of rated current
Over Voltage Protection
Detection above approx. 114~145% of rated voltage
Remote Sensing
N/A
Remote On/Off Control
N/A
A
d
d
i
ti
on
al
F
unct
i
o
n
s
Display
N/A
Operating Temperature
It shall be operated by 80% of rated current at -10~0
C and 50~60
C
-10~+60
C
Storage Temperature
-25~+85
C
Operating Humidity
Env
i
r
o
nme
n
t
a
l
Storage Humidity
30~90% (No Condensation)
Between Input and
Output
Between Input and
Frame
AC2000V for 1 minute / AC2400V for 3 seconds
Insulation Withstad
Voltage
Between Output and
Frame
AC500V for 1 minute / AC600V for 3 seconds
Between Input and
Output
Between Input and
Frame
Ins
u
la
t
i
o
n
Insulation Resistance
Between Output and
Frame
100M
(measured with 500V DC Megger)
Vibration Resistance
10~55Hz 10G 1 hour (X,Y,and Z directions with 3 min. vibration time)
Cooling Requirements
Natural Convection
External Appearance (W x D x H) mm
43 x 50 x 19
43 x 55 x 20
Structural
Specifications
Weight (g)
67
84
Safety Standards
UL1950,CSA C22.2 No.234,Dentori
Applica
b
le
St
a
nda
rds
EMI Standards
FCC Class B, VCCI Class 2