ChipFind - документация

Электронный компонент: NAL40-7628

Скачать:  PDF   ZIP
LOW TO MEDIUM POWER AC/DC POWER SUPPLIES 40W AC/DC Universal Input Switch Mode Power Supplies
1
2 YEAR WARRANTY
NAL40 Series
S i n g l e , d u a l a n d t r i p l e o u t p u t
5.0 x 3.0 x 1.2 inch package (1U applications)
Ideal for high volume designs
Industry standard package
Overvoltage and short circuit protection
40W with free air convection
EN55022, EN55011 conducted emissions level A
The NAL40 series are 40W universal input AC/DC power supplies on a 5 x 3 inch card
with a maximum component height of 1.2 inch for use in 1U applications. These series
are available with a wide range of models in the industry standard 5 x 3 inch footprint
at low cost making the series ideal for new and existing high volume communication
and industrial applications. The NAL40 meets level A conducted emissions. The NAL40
series provide 40W of output power with free air convection cooling with a peak output
of 50W for a maximum duration of 60 seconds. The NAL40 series are designed for use
in high volume low power data networking, computer and telecom applications such as
hubs, routers, POS terminals, cable modems and PABX's. This list is not exclusive as
the generic feature set of both series with industry standard output configurations
provide a solution for most high volume applications including many industrial
applications.
All specifications are typical at nominal input, full load at 25C unless otherwise stated
EMC CHARACTERISTICS
Conducted emissions
EN55022, FCC part 15
level A
Radiated emissions
EN55022, FCC part 15
level A
ESD air
EN61000-4-2, level 3
Perf. criteria 2
ESD contact
EN61000-4-2, level 4
Perf. criteria 2
Surge
EN61000-4-5, level 3
Perf. criteria 2
Fast transients
EN61000-4-4, level 3
Perf. criteria 2
Radiated immunity
EN61000-4-3, level 3
Perf. criteria 2
Conducted immunity
EN61000-4-6, level 3
Perf. criteria 2
GENERAL SPECIFICATIONS
Hold-up time
110VAC
10ms @ 40W
230VAC
60ms @ 40W
Efficiency
68% min. @ 40W
Isolation voltage
Input/output
3000VAC
Input/chassis
1500VAC
Switching frequency
Variable
Approvals and
VDE0805, EN60950, IEC950
standards
BABT, IEC1010, UL1950
(See Note 9)
CSA C22.2 No. 950
Weight
200g (7.06oz)
MTBF
MIL-HDBK-217F
150,000 Hours
ENVIRONMENTAL SPECIFICATIONS
Thermal performance
Operating
0C to +70C
Non-operating
-40C to +85C
0C to 50C ambient,
40W
convection cooled
50C to 70C,
Derate linearly
ambient conv. cooled
to half load
Peak (0C to 50C) max. 60s
50W
Relative humidity
Non-condensing
5% to 95% RH
Altitude
Operating
10,000 feet max.
Non operating
30,000 feet max.
Vibration
Three orthogonal axes,
2.4G rms
random vibration, 10
5Hz to 500Hz
minute test for each axis
OUTPUT SPECIFICATIONS
Line regulation
Main output
0.5%
Auxiliary outputs
1.0%
Total regulation
Main output
3.0%
Auxiliary outputs
5.0%
Overshoot/undershoot
At turn-on
<10%
Transient response
+5.1V
150mV max. dev.,
(1.5A to 3A step)
500s recovery
Temperature coefficient
0.02%/C
Overvoltage protection
+5.1V output
6.25V 0.75Vout
Output power limit
Primary power
50W Pout, min.
limited
110W Pin, max.
Short circuit protection
Multiple output
30 seconds
Single 12V, 15V,
Continuous
24V and 48V
automatic recovery
INPUT SPECIFICATIONS
Input voltage range
Universal input
90 to 264VAC
120 to 370VDC
Input frequency range
47Hz to 440Hz
Input surge current
110VAC, cold start
15A
230VAC, cold start
32A
Safety ground
110VAC, 60Hz
0.2mA
leakage current
230VAC, 50Hz
0.4mA
SPECIFICATIONS
File Name: NAL40.PDF Rev: 19 Nov 2001
For the most current data and application support visit www.artesyn.com/powergroup/products.htm
Notes
1
Natural convection cooling (40W maximum).
2
Peak output current lasting less than 60 seconds with duty cycle less than
5%. During peak loading, output voltage may exceed total regulation limits.
3
Forced air, 20CFM at 1 atmosphere, 50W maximum.
4
Figure is peak-to-peak. Output noise measurements are made across a
50MHz bandwidth using a 12 inch twisted pair, terminated with a 47F
capacitor.
5
Total regulation is defined as the static output regulation at 25C, including
initial tolerance, line voltage within stated limits, load currents within stated
limits and output voltages adjusted to their factory settings. For multiple
output units to maintain stated regulation then:
0.25
I
A
/ I
B
5, for I
B
> 0.3A
0.50
I
A
/ I
B
5, for I
B
< 0.3A
Minimum load must also be 4W to achieve design MTBF.
For maximum output current I
C
on triple-output models, i.e. for:
I
C
= IMax., then I
A
min.
0.5A and I
B
I
C
.
This does not apply to the NAL40-7628 which has a separately regulated
output, see note 8.
6
Derating curve is application specific for ambient temperatures >50C, for
optimum reliability, no part of the heatsink should exceed 120C, and no
semiconductor case temperature should exceed 130C.
7
Caution: allow a minimum of 1 second after disconnecting line power when
making thermal measurements.
8
The NAL40-7628 has separately linear regulated +12V and -12V outputs.
The loading conditions in note 5 do not apply.
9
This product is only for inclusion by professional installers within other
equipment and must not be operated as a stand alone product.
NAL40 Series
S i n g l e , d u a l a n d t r i p l e o u t p u t
LOW TO MEDIUM POWER AC/DC POWER SUPPLIES 40W AC/DC Universal Input Switch Mode Power Supplies
2
www.artesyn.com
File Name: NAL40.PDF Rev: 19 Nov 2001
OUTPUT
OUTPUT CURRENT
RIPPLE
(4)
TOTAL
MODEL NUMBER
(B)
VOLTAGE
MAX
(1)
PEAK
(2)
FAN
(3)
REG.
(5)
+ 5.1V (I
A
)
3A
7A
4A
50mV
3.0%
NAL40-7608
(5)
+12V (I
B
)
2A
3A
2A
120mV
5.0%
12V (I
C
)
0.35A
1A
0.5A
120mV
5.0%
+5.1V
3A
7A
4A
45mV
3.0%
NAL40-7628
(8)
+12V
0.35A
3A
0.5A
110mV
5.0%
12V
0.35A
1A
0.5A
110mV
5.0%
+5.1V (I
A
)
3A
7A
4A
50mV
3.0%
NAL40-7607
(5)
+12V (I
B
)
2A
3A
2A
120mV
5.0%
5V (I
C
)
0.35A
1.0A
0.5A
50mV
5.0%
+5.1V (I
A
)
3A
7A
4A
50mV
3.0%
NAL40-7610
(5)
+15V (I
B
)
1.5A
3A
1.5A
160mV
+13% 0%
15V (I
C
)
0.35A
1A
0.5A
150mV
5.0%
+5.1V (I
A
)
3A
7A
4A
50mV
3.0%
NAL40-7629
(5)
+12V (I
B
)
2A
3A
2A
120mV
5.0%
5V
6A
10A
8A
50mV
3.0%
NAL40-7605
12V
3.3A
5A
4A
120mV
3.0%
NAL40-7612
15V
2.6A
4A
3.3A
150mV
3.0%
NAL40-7615
24V
1.6A
2.5A
2A
240mV
3.0%
NAL40-7624
48V
0.8A
1A
1A
480mV
3.0%
NAL40-7617
20W
40W
50W
4W
25W
0
C 10
C 20
C 30
C 40
C 50
C 60
C 70
C
Available Output Power V's Ambient Temperature
DERATING CURVE (See Notes 6, 7)
Output Power (Watts)
NATURAL
CONVECTION
COOLING
4W MIN. LOAD TO ACHIEVE DESIGN MTBF
20 CFM FORCED AIR COOLING
0.156 (3.96) Dia. (4 Places)
5.00
(127.00)
MAXIMUM COMPONENT
HEIGHT 1.2 inches
J2
P1
F1
J1
F3.15A, 250VAC
2.55
(64.80)
0.22
(5.59)
3.00
(76.20)
4.55
(115.80)
1
0.22
(5.59)
ALL DIMENSIONS IN INCHES (mm)
T1
1
Data Sheet Artesyn Technologies 2002
The information and specifications contained in this data sheet are believed to be correct at time of publication. However, Artesyn Technologies accepts no responsibility for consequences arising
from printing errors or inaccuracies. Specifications are subject to change without notice. No rights under any patent accompany the sale of any such product(s) or information contained herein.
For the most current data and application support visit www.artesyn.com/powergroup/products.htm
NAL40 Series
S i n g l e , d u a l a n d t r i p l e o u t p u t
LOW TO MEDIUM POWER AC/DC POWER SUPPLIES 40W AC/DC Universal Input Switch Mode Power Supplies
3
www.artesyn.com
File Name: NAL40.PDF Rev: 19 Nov 2001
Mechanical Notes
A
Ground pad encircling mounting hole near P1 allows system grounding
through a metal stand-off of up to 8mm max. diameter to metal chassis.
B
A standard L-bracket and cover is available for mounting, which contains
all screws, connectors and necessary mounting hardware. Order part
number `NAL40 COVER KIT'.
International Safety Standard Approvals
VDE0805/EN60950/IEC950/IEC1010 File No. 10401-3336-1076
Licence No. 70567, 1076 and 90354
UL1950 File No. E136005
CSA C22.2 No. 950 File No. LR41062C
Certificate No. PS/605108
OUTPUT PIN CONNECTIONS
J2
SINGLE
DUAL
TRIPLE
P1
+Vout
+12V
V (B)
P2
+Vout
+5.1V
V (A)
P3
+Vout
+5.1V
V (A)
P4
Return
Return
Return
P5
Return
Return
Return
P6
Return
N/C
V (C)
INPUT
PIN CONNECTIONS
J1
Pin 1
AC Neutral
Pin 2
No Pin
Pin 3
AC Line
P1
Pin 1
Safety Ground
AC (J1) mating connector
Molex 09-50-3031 or equiv. with Molex 08-50-0105 or equiv. crimp terminals.
DC (J2) mating connector