LOW TO MEDIUM POWER AC/DC POWER SUPPLIES 80-110W AC/DC Universal Input Switch Mode Power Supplies
1
2 YEAR WARRANTY
NLS110-9602
Q u a d o u t p u t
7.0 x 4.25 x 1U package
Overvoltage and short circuit protection
110W with 20CFM
90VAC to 264VAC universal input range
EN55022 conducted emissions level B, radiated
emissions level A
UL, VDE and CSA safety approvals
CE mark
The NLS110-9602 is a 110W universal input AC/DC power supply on a 7 x 4.25 inch
card. The NLS110-9602 has proven itself to be highly reliable and versatile product for
a wide range of communication and industrial applications, with a very high peak
current capability on each output for drive and motor applications. The NLS110-9602
provides 80W of output power with free air convection cooling which can be boosted to
110W with 20CFM of air. Standard features include overvoltage and short circuit
protection. The NLS110-9602 with full international safety approval and the CE mark,
meets conducted emissions EN55022 level B. The NLS110-9602 is designed for use in
low power data networking, computer, telecom and industrial applications such as
servers, thermal printers, storage devices, vending machines and POS equipment.
All specifications are typical at nominal input, full load at 25C unless otherwise stated
GENERAL SPECIFICATIONS
Hold-up time
120VAC @ 60Hz
35ms @ 80W
25ms @ 110W
Efficiency
120VAC @ 110W
70% min.
Isolation voltage
Input/output
3000VAC
Input/chassis
1500VAC
Approvals and
EN60950, VDE0805, IEC950
standards
UL1950, CSA C22.2 No. 950
Weight
383g (13.5 oz.)
MTBF (@ 25C)
MIL-HDBK-217F
220,000 hours min.
ENVIRONMENTAL SPECIFICATIONS
(6,8)
Thermal performance
Operating ambient,
0C to +50C
(see derating curve)
Non-operating
40C to +85C
+50C to +70C,
Derate to
amb. convection cooled
50% load
0C to +50C,
80W
amb. convection cooled
0C to +50C ambient,
110W
150LFM forced air
Peak (0C to +50C, 60s)
(See Note 4)
Relative humidity
Non-condensing
5% to 95% RH
Altitude
Operating
10,000 feet max.
Non-operating
30,000 feet max.
Vibration (See Note 7)
5Hz to 500Hz
2.4G rms peak
Shock
per MIL-STD-810E
516.4 Part IV
OUTPUT SPECIFICATIONS
Total regulation
Line and load
(See table)
Rise Time
At turn-on
1.0s, max.
Transient response
(See table)
Temperature coefficient
0.02%/C
Overvoltage protection
+5.1V
125%, 10%
Short circuit protection
Cyclic operation
Yes with auto
recovery
INPUT SPECIFICATIONS
Input voltage range
Universal input
90 to 264VDC
Input frequency range
47Hz to 440Hz
Input surge current
120VAC
18A max.
(cold start)
230VAC
35A max.
Safety ground
120VAC, 60Hz
0.45mA
leakage current
230VAC, 50Hz
0.75mA
Input current
120VAC @ 80W
0.95A rms
120VAC @ 110W
1.35A rms
230VAC @ 80W
0.53A rms
230VAC @ 110W
0.75A rms
Input fuse
UL/IEC127
F3.15A H, 250VAC
EMC CHARACTERISTICS
(11)
Conducted emissions
EN55022, FCC part 15
Level B
Radiated emissions
EN55022, FCC part 15
Level A
Harmonic current
EN61000-3-2
Compliant
emission correction
ESD air
EN61000-4-2
Level 3
ESD contact
EN61000-4-2
Level 3
Surge
EN61000-4-5
Level 3
Fast transients
EN61000-4-4
Level 3
Radiated immunity
EN61000-4-3
Level 3
Conducted immunity
EN61000-4-6
Level 3
SPECIFICATIONS
File Name: NLS110.PDF Rev: 12 June 2001
For the most current data and application support visit www.artesyn.com/powergroup/products.htm
Notes
1
Convection cooled, 80W maximum.
2
Peak outputs lasting less than 60 seconds with duty cycle less than 10%.
Total peak power must not exceed 110W.
3
Forced air, 20CFM at 1 atmosphere, 110W maximum.
4
Amplitude is peak-to-peak. Output ripple is measured across a 20MHz
bandwidth using a 12 inch twisted pair terminated with a 10F capacitor.
5
Total regulation is defined as the static output regulation at 25C, including
initial tolerance, line voltage within stated limits and output voltages
adjusted to their factory settings.
6
Derating curve is application specific for ambient temperatures >50C.
7
Three orthogonal axes, random vibration, 10 minute test for each axis.
8
For optimum reliability no part of the heatsink should exceed 100
o
C and no
semiconductor case temperature should exceed 115
o
C.
9
Caution: Allow a minimum of 1 second after disconnecting the power when
making thermal measurements.
10
This product is only for inclusion by professional installers within other
equipment and must not be operated as a stand alone product.
11
The EMI specifications reference measurements made with the power
supply mounted on a grounded metal sheet extending 1 inch beyond each
edge, using an unshielded cable. No external filtering is required during
conducted emissions testing but some applications may require additional
filtering to achieve system compliance. A line choke, (AC input cords
looped twice through an EMI suppression toroid) was used during radiated
emissions testing. Considerable radiated testing in 1U six-sided boxes has
shown that units can meet level B in typical systems. Application support
is available from the factory to assist with EMI compliance.
12
Requires a minimum mounting stand-off of 6.35mm (0.25 inches) in the end
use product.
TRANSIENT RESPONSE
NLS110-9602
+5.1V (7.5A to 10A)
150mV peak,
1ms recovery
+24V (1.5A to 3A)
300mV peak,
1ms recovery
+12V (2.5A to 5A)
100mV peak,
0.5ms recovery
-12V (0.5A to 1A)
100mV peak,
0.5ms recovery
NLS110-9602
Q u a d o u t p u t
LOW TO MEDIUM POWER AC/DC POWER SUPPLIES 80-110W AC/DC Universal Input Switch Mode Power Supplies
2
Please consult our website for the following items:
Application Note
www.artesyn.com
File Name: NLS110.PDF Rev: 12 June 2001
OUTPUT
OUTPUT CURRENTS
RIPPLE
(4)
TOTAL
MODEL NUMBERS
VOLTAGE
MAX
(1)
PEAK
(2)
FAN
(3)
REGULATION
(5)
+5.1V
8.0A
20.0A
10.0A
50mV
2.0%
NLS110-9602
(12)
+24.0V
3.5A
4.5A
4.5A
240mV
5.0%
+12.0V
4.5A
9.0A
5.0A
120mV
3.0%
12.0V
0.5A
1.5A
1.0A
120mV
3.0%
Power fail detect signal
50ms
T1
200ms
T2 will vary with line and load
T3
3ms
Pout: 110W
PFD output is an open collector
which will sink
40mA in the low
state.
HIGH
T1
T2
T3
4.75V
3.5V MIN
0-0.4 MAX
LOW
4.75V
5V OUTPUT
PFD SIGNAL
AC INPUT
OPTIONAL POWER FAIL DETECT TIMING DIAGRAM
DERATING CURVE
Output Power (Watts)
0
C 10
C 20
C 30
C 40
C 50
C 60
C 70
C
40W
80W
110W
150 LFM FORCED
AIR COOLING
55W
NATURAL
CONVECTION
COOLING
OUTPUT PIN CONNECTIONS
J2
FUNCTION
Pin 1
+5.1V
Pin 2
+5.1V
Pin 3
Return
Pin 4
Return
Pin 5
Return
Pin 6
Return
Pin 7
+12V
Pin 8
+12V
Pin 9
+24V
Pin 10
PFD
Pin 11
-12V Return
Pin 12
-12V
INPUT
PIN CONNECTIONS
J1
Pin 1
AC Neutral
Pin 2
No Connection
Pin 3
AC Line
J4
Pin 1
Safety Earth
Input and output connectors
Mating connectors
AC (J1) connector type
AC (J1) mating connector type
Molex 26-60-4030 or equivalent.
Molex 09-50-3031 or equivalent with Molex
08-50-0105 or equivalent crimp terminals.
DC (J2) connector type
DC (J2) mating connector type
12 position Molex Spox type 26-48-1125
Molex Spox type 26-03-3121 and
or equivalent.
contact 08-52-0113.
Earth (J4) connector type
Earth (J4) mating connector type
Male 0.250 quick disconnect.
Molex 90028.
4.25
(107.95)
0.25 (6.35)
0.25 (6.35)
3.750
(95.250)
3
J1
J2
J5
12
7.00 (177.80)
6.500 (165.100)
1
1
2
J4
T1 (REF)
T2 (REF)
F1
1
TOLERANCE: .XXX:
0.005 (0.127)
.XX:
0.02 (0.51)
ALL DIMENSIONS IN INCHES (mm)
Recommended direction
for forced air relative to
power supply orientation
shown below.
1
Optimum.
2
Very good.
3
Not recommended.
4
Not recommended.
2
3
4
1
Data Sheet Artesyn Technologies 2002
The information and specifications contained in this data sheet are believed to be correct at time of publication. However, Artesyn Technologies accepts no responsibility for consequences arising
from printing errors or inaccuracies. Specifications are subject to change without notice. No rights under any patent accompany the sale of any such product(s) or information contained herein.
For the most current data and application support visit www.artesyn.com/powergroup/products.htm
NLS110-9602
Q u a d o u t p u t
LOW TO MEDIUM POWER AC/DC POWER SUPPLIES 80-110W AC/DC Universal Input Switch Mode Power Supplies
3
Please consult our website for the following items:
Application Note
www.artesyn.com
File Name: NLS110.PDF Rev: 12 June 2001
Mechanical Notes
A
All dimensions are in inches (mm).
International Safety Standard Approvals
VDE0805/EN60950/IEC950/IEC1010 File No. 10401-3336-1049
Licence No. 2874, 1653 and 1049
UL1950 File No. E136005
CSA C22.2 No. 950 File No. LR41062C