ChipFind - документация

Электронный компонент: LPS175

Скачать:  PDF   ZIP
Technical Support: (888) 41-ASTEC or (407) 241-2752
Americas: (760) 930-4600 Europe (UK) 44 (1384) 842-211
Asia (HK) 852-2437-9662
118
Special Features
Electrical Specs
Active power factor correction
IEC EN61000-3-2 compliance
Wide Range Adjustable output
Remote sense on main output
Single wire current sharing
Power fail and remote inhibit
Built-in EMI filter
Low output ripple
Overvoltage protection
Overload protection
Thermal overload protection
DC power good
5 V standby output
12 V Aux output
Optional cover (-C suffix)
Operating temperature: 0 to 50C ambientderate
each output at 2.5% per degree from 50 to 70C
Electromagnetic susceptibility: designed to meet
IEC EN61000-4, -2, -3, -4, -5, -6, -8, -11, Level 3
Humidity: Operating; non-condensing
5% to 95%
Vibration: Three orthogonal axes, sweep at
1 oct/min, 5 min. dwell at four major resonances
0.75 G peak 5 Hz to 500 Hz, operational
Storage temperature: -40 to 85C
Temperature coefficient: .04% per C
MTBF demonstrated: >550,000 hours at full load
and 25C ambient conditions
Input
Input range
85-264 VAC, 120-300 VDC
Frequency
47-63 Hz
Inrush current
38 A max, cold start @ 25C
Efficiency
75% typical at full load
EMI filter
Meets FCC Class B conducted
CISPR 22 Class B conducted
EN55022 Class B conducted
VDE 0878 PT3 Class B conducted
Power factor
0.99 typical
Safety ground leakage
current
1.0 mA @ 50/60 Hz, 264 VAC input
Output
Maximum power
110 W convection (75 W with cover)
175 W with 30 CFM forced air
(130 W with cover)
Adjustment range
2:1 wide ratio minimum
Hold-up time
20 ms @175 W load at nominal line
Overload protection
Short circuit protection on all outputs.
Case overload protected @ 110-145%
above peak rating
Overvoltage protection
10% to 40% above nominal output
Standby output
5 V @ 2A regulated 5%
Aux output
12 V @ 1 A -5 %, +10%
Logic Control
Power failure
TTL logic signal goes high 100 - 500
msec after V1 output; It goes low at
least 4 msec before loss of regulation
Remote inhibit
Requires contact closure to inhibit
outputs
Remote sense
Compensates for 0.5 V lead drop min.
Will operate without remote sense
connected. Reverse connection
protected.
DC-OK
TTL logic signal goes high after main
output is in regulation. It goes low
when there is a loss of regulation
VDE
0805/EN60950 (IEC950)
UL
UL1950
CB
Certificate and report
CSA
CSA 22.2-234 Level 3
CE
Mark (LVD)
NEMKO
EN 60950/EMKO-TUE
Environmental
Safety
175 Watts
LPS170 Series
Total Power:
110-175 Watts
Input Voltage: 85-264 VAC
120-300 VDC
# of Outputs:
Single
rev 08.09.03
EUROPE
Astec House, Waterfront Business Park
Merry Hill, Dudley
West Midlands, DY5 1LX, UK
Telephone: 44 (1384) 842-211
Facsimile: 44 (1384) 843-355
AMERICAS
5810 Van Allen Way
Carlsbad, CA 92008
Telephone: 760-930-4600
Facsimile: 760-930-0698
119
www.astecpower.com
Ordering Information
ASIA
Units 2111-2116, Level 21
Tower1, Metroplaza
223, Hing Fong Road
Fwai Fong, New Territories
Hong Kong
Telephone: 852-2437-9662
Facsimile: 852-2402-4426
Model
Output
Minimum
Maximum Load with
Maximum Load with
Peak
Regulation2
Ripple
Number
Voltage
Load
Convection Cooling
30 CFM Forced Air
Load
P/P(PARD)3
LPS172
5 V (2.5-6V)
0 A
22 A
35 A
38 A
2%
50 mV
LPS173
12 V (6-12 V)
0 A
9.1 A
15 A
16.5 A
2%
120 mV
LPS174
15 V (12-24 V)
0 A
7.3 A
12 A
13.2 A
2%
<1%
LPS175
24 V (24-54 V)
0 A
4.5 A
7.5 A
8.2 A
2%
<1%
1. Peak current lasting <30 seconds with a maximum 10% duty cycle.
2. At 25C including initial tolerance, line voltage, load currents and output voltages adjusted to factory settings.
3. Peak-to-peak with 20 MHz bandwidth and 10 F in parallel with a 0.1 F capacitor at rated line voltage and load ranges.
4. Remote inhibit resets OVP latch
Note: -C suffix added to the model number indicates cover option.
5 3 1
SK4
1
5
6
10
SK1
+ -
SK3
Voltage Adj
POT
8.5
(216.0)
7.4
(188.0)
6.61
(168.0)
0.55
(14.0)
0.95
(24.0)
1.50
(38.1)
0.75
(19.0)
M3
#6-32
0.88
(22.2)
2.5
0
(63
.
5)
1.07
(27.2)
2.11
(53.5)
#6-32(8 PLACES)
M3(8 PLACES)
4.25
(108.0)
Connector
LPS17x
SK1
PIN 1
+12V
PIN 2
5V Standby
PIN 3
Common
PIN 4
V1 SWP
PIN 5
Common
PIN 6
+V1 sense
PIN 7
Sense common
PIN 8
Remote inhibit
PIN 9
DC power good
PIN 10
POK
SK3
TB-1
COMMON
TB-2
Main output
SK4
PIN 1
GROUND
PIN 3
LINE
PIN 5
NEUTRAL
Mating Connectors
(SK4) AC Input:
Molex 09-50-8051 (USA)
Molex 09-91-0500 (UK)
PINS: 08-58-0111
(SK3) DC Output:
Molex 19141-0058
(SK1) Control Signals:
Molex 90142-0010 (USA)
PINS: 90119-2110 or
Amp: 87977-3
PINS: 87309-8
Astec connector kit #70-841-016
Notes:
1. Specifications subject to change without notice.
2. All dimensions in inches (mm), tolerance is 0.02".
3. Specifications are for convection rating at factory settings unless
otherwise stated.
4. Mounting screw maximum insertion depth is 0.12".
5. Warranty: 1 year
6. Weight: 1.8 lb / 0.85 kg
Ordering Information
LPS170 Series