ChipFind - документация

Электронный компонент: NTQ123

Скачать:  PDF   ZIP
rev 12.12.03
Technical Support: (888) 41-ASTEC or (407) 241-2752
Americas: (760) 930-4600 Europe (UK) 44 (1384) 842-211
Asia (HK) 852-2437-9662
106
Special Features
Electrical Specs
70-120 Watts
NTQ123 Series
Active power factor correction
EN61000-3-2 compliance
Remote sense on outputs one and two
Power fail and remote inhibit
Single wire current sharing on outputs one
and two
Adjustable main outputs
Built-in Class B EMI filter
Overvoltage protection
Overload protection
Thermal overload protection
Operating temperature: 0 to 50C ambient; derate
each output at 2.5% per degree from
50 to 70C
Electromagnetic susceptibility: Designed to meet
EN61000-4, -2, -3, -4, -5, -6, -8, -11 Level 3
Humidity: Operating; non-condensing
5% to 95%
Vibration: Three orthogonal axes, sweep at
1 oct/min, 5 min. dwell at four major resonances
0.7 G peak 5 Hz to 500 Hz, operational
Storage temperature: -40 to 85C
Temperature coefficient: .04% per C
MTBF demonstrated: >1 million hours at full load
and 25C ambient conditions
Input
Input range
85-264 VAC
Frequency
47-63 Hz
Inrush current
38 A max., cold start @ 25C
Efficiency
65% typical at full load
EMI filter
FCC Class B conducted and radiated,
CISPR 22 Class B conducted and
radiated, EN55022 Class B conducted
and radiated, VDE 0878 PT3 Class B
conducted and radiated.
Power factor
0.99 typical
Safety ground leakage
current
<1 mA @ 50/60 Hz, 264 VAC input
Output
Maximum power
70 W convection,
120 W with 30 CFM forced air
Adjustment range
5% minimum on outputs one and two
Hold-up time
20 ms @ 120 W load, 120 VAC input
Overload protection
Short circuit protection on all outputs.
Case overload protected @ 110-145%
above peak rating
Overvoltage protection
3.3 V and 5 V output: 20% to 35%
above nominal output
Logic Control
Power failure
TTL logic signal goes high 100-500
msec after 5 V output; it goes low at
least 4 msec before loss of regulation
Remote inhibit
Requires an external TTL Signal to
inhibit outputs
Remote sense
Compensates for 0.5 V lead drop
minimum, will operate without
remote sense connected. Reverse
connection protection.
Environmental
Safety
VDE 0805/EN60950 (IEC950)
21310-3336-0004
UL
UL1950
E186249
CSA
CSA 22.2-234 Level 3 LR109492C
NEMKO
EN 60950/EMKO-TUE P98100870
(74-sec) 203
CB
Certificate and report
5009
CE
Mark (LVD)
Total Power:
70-120 Watts
Input Voltage: 85-264 VAC
# of Outputs:
Quad
EUROPE
Astec House, Waterfront Business Park
Merry Hill, Dudley
West Midlands, DY5 1LX, UK
Telephone: 44 (1384) 842-211
Facsimile: 44 (1384) 843-355
AMERICAS
5810 Van Allen Way
Carlsbad, CA 92008
Telephone: 760-930-4600
Facsimile: 760-930-0698
107
www.astecpower.com
Ordering Information
ASIA
Units 2111-2116, Level 21
Tower1, Metroplaza
223, Hing Fong Road
Fwai Fong, New Territories
Hong Kong
Telephone: 852-2437-9662
Facsimile: 852-2402-4426
4.00
(101.6)
1.5
(38.1)
.75 (19.0)
.5625
7.0
(177.8)
6.5
(165.1)
2.5
(63.5)
SK4
#6-32 UNC (8 places)
5 3 1
5 3 1
5.5
(139.7)
4.7
(119.6)
M3 (4 places)
SK5
123
5V adj
VR401 VR403
+3.3V
SK6
SK1
COMMON
+5V
M 3.5
(3 places)
MAIN OUTPUTS
5 3 1
SK2
SK3
SK4
3.3V adj
6
7
8
9
1
1
2
3
4
5
0
Model Output
Minimum
Maximum Load with
Maximum Load with
Peak
Regulation
2
Ripple
Number
Voltage
Load
4
Convection Cooling
30 CFM Forced Air
Load
1
P/P (PARD)
3
NTQ123
+3.3 V
0 A
14 A
25 A
28 A
2%
50 mV
+5 V
2 A
12.5 A
24 A
28 A
2%
50 mV
+12 V
0 A
1 A
2 A
4 A
3%
120 mV
-12 V
0 A
0.5 A
1 A
1.5 A
3%
120 mV
1. Peak current lasting <30 seconds with a maximum 10% duty cycle.
2. At 25C including initial tolerance, line voltage, load currents and output voltages adjusted to factory settings.
3. Peak-to-peak with 20 MHz bandwidth and 10 F in parallel with a 0.1 F capacitor at rated line voltage and load ranges.
4. Minimum loads are required. In parallel minimum loads are 2.5 A on the 5 V output and 1 A on the 3.3 V output for each power supply.
Connector
SK1
PIN 1
Ground
PIN 3
Neutral
PIN 5
Live
SK5
PIN 1
+12 V
PIN 2
Common
PIN 3
-12 V
SK6
PIN 1
3.3 V SWP
PIN 2
-3.3 V Sense
PIN 3
+3.3 V + Sense
PIN 4
5 V SWP
PIN 5
COMMON
PIN 6
+5 V Sense
PIN 7
-5 V Sense
PIN 8
+ Inhibit
PIN 9
- Inhibit
PIN 10
Power Fail
Mating Connectors
(SK1) AC Input:
Molex: 09-50-8051 (USA)
Molex: 09-91-0500 (UK)
PINS: 08-58-0111
SK2,3,4:
Molex BB-124-08
(SK5) 12V Molex:09-50-8031 (USA)
Molex: 09-91-0300 (UK)
PINS: 08-58-0111
(SK6) Control Signals:
Molex: 90142-0010
PINS: 90119-2110
or
Amp: 87977-3
PINS: 87309-8
Astec Connector Kit #70-841-012, includes al of the above.
Notes:
1. Specifications subject to change without notice.
2. All dimensions in inches (mm), tolerance .02".
3. Remote inhibit requires an external 5 V @ 10 mA
to activate
4. Mounting maximum insertion depth is 0.12".
5. Warranty: 1 year
6. Weight: 1.38 lb. / .63 kg
Pin Assignments
NTQ123 Series