Special Features
Electrical Specs
40 Watts
SA40-1313 Series
TUV
IEC950
R9153228
UL
UL1950
E132002
CSA
CSA22.2-234
LR53982C
VDE
VDE0805, IEC 950
11774-3336-1164
EN
60950
CB
certificate and report
UL330-132002 / USA
Low cost
Universal input
3" x 5" footprint
Built-in EMI filter
Low output ripple
100% computerized final testing
Overvoltage protection
Overload protection
Operating temperature: 0 to 50C ambient
Storage temperature: -40 to 85C
Thermal regulation: .04% per C
MTBF: >100,000 hours at full load and 25C
ambient conditions per MIL-HDBK-217E
Input
Input range
85-264 VAC
Frequency
47-63 Hz
Inrush current
<25 A peak @ 115 VAC;
<50 A peak @ 230 VAC,
cold start at 25C
Input current
1 A max. (RMS) @ 115 VAC;
0.5 A max (RMS) @ 230 VAC
Efficiency
70% typical at full load, nominal line
Power factor
>0.65
EMI filter
Meets FCC 20780 Class B and
VDE 0871 Level B
Output
Maximum power
40 W convection
Cross regulation
2% on output 1;
5% on outputs 2, 3
Overshoot
None
Hold-up time
20 ms @ full load, 115 VAC nominal
line
Overvoltage protection
+5 V trip voltage less than 6.8 V;
recycle AC safety ground to reset
Safety ground
Leakage current
< 0.5 mA @ 250 VAC, 50 Hz
Overload protection
Short circuit protected on all outputs
Total Power:
40 Watts
Input Voltage:
85-264 VAC
# of Outputs:
Triple
Environmental
Safety
America's (USA): 1-888-41-ASTEC
Europe (UK): 44 (1384) 842-211
Asia (HK): 852-2437-9662
88
W9959_03_LP_final_074-098_25 2/8/02 4:03 PM Page 88
ASIA
Units 2111-2116, Level 21
Tower1, Metroplaza
223, Hing Fong Road
Fwai Fong, New Territories
Hong Kong
Telephone: 852-2437-9662
Facsimile: 852-2402-4426
EUROPE
Astec House, Waterfront Business Park
Merry Hill, Dudley
West Midlands, DY5 1LX, UK
Telephone: 44 (1384) 842-211
Facsimile: 44(1384) 843-355
AMERICAS
5810 Van Allen Way
Carlsbad, CA 92008
Telephone: 760-930-4600
Facsimile: 760-930-0698
Ordering Information
Model
Output
Minimum
Maximum
Peak
Regulation
2
Ripple
Number
Voltage
Load
Load
Load
1
P/P (PARD)
3
SA40-1313
5 V
0.45 A
5 A
--
+5%, -4%
50 mV
12 V
0.3 A
3 A
4.5 A
5%
120 mV
-12 V
0 A
0.35 A
--
10%
120 mV
1. Peak current lasting <20 seconds. (Maximum Po = 60 W)
2. At 25C including initial tolerance, line voltage, load currents and output voltages adjusted to factory settings.
3. Peak-to-peak with 20 MHz bandwidth and 10 F capacitor in parallel with 0.1 F capacitor at rated line voltage and load ranges.
Connector
SA40-1313
SK1-1
Live
SK1-2
Pin removed
SK1-3
Neutral
SK2-1
+12 V
SK2-2
+5 V
SK2-3
+5 V
SK2-4
Common
SK2-5Common
SK2-6
-12 V
Mating Connectors
AC Input:
Molex 09-91-0300
DC Outputs: Molex 09-91-0600
Notes:
1. Specifications subject to change without notice.
2. All dimensions in inches (mm).
3. Mounting holes M1, M2 and M3 should be grounded for
EMI purposes.
4. Mounting hole M1 is safety ground connection.
5. Specifications are for convection rating at factory settings
at 115 VAC input, 25C unless otherwise stated.
6. For safety purposes, on mounting hole M4 use plastic
standoff.
7. Warranty: 1 year
8. Weight: 0.54 lb / 0.25 kg
0.14 (3.5)
2.57
(65.2)
0.156
(4)
.022
(5.5)
0.22
(5.5)
1.34
(34.0)
4.57 (116.0)
5.0 (127.0)
SK 1
N
L
+
SK 2
1
2
3
4
5
6
DIA (3 places)
0.12
(3)
M1
M2
M3
M4
3
2
1
3.0
(76.2)
Pin Assignments
S
A40-1313
Series
89
www.astec.com