KST-9067-002
1
STN2907A
PNP Silicon Transistor
Descriptions
General purpose application
Switching application
Features
Large collector current
Low collector saturation voltage
Complementary pair with STN2222A
Ordering
Information
Type NO. Marking Package Code
STN2907A STN2907A TO-92
Outline Dimensions unit :
mm
4.4~4.6
4.
4~4.
6
0.38~0.42
1.27 Typ
.
2.54 Typ
.
1 2 3
3.35~3.55
2.15~2.35
1.96~2.16
1.
1~1.
3
0.
38
14.
0
0.
40
S
S
e
e
m
m
i
i
c
c
o
o
n
n
d
d
u
u
c
c
t
t
o
o
r
r
PIN Connections
1. Emitter
2. Base
3. Collector
KST-9067-002
2
STN2907A
Absolute maximum ratings
Ta=25
C
Characteristic Symbol
Ratings
Unit
Collector-Base voltage
V
CBO
-60 V
Collector-Emitter voltage
V
CEO
-50 V
Emitter-base voltage
V
EBO
-5 V
Collector current
I
C
-600
mA
Collector dissipation
P
C
625
mW
Junction temperature
T
j
150
C
Storage temperature
T
stg
-55~150 C
Electrical Characteristics
Ta=25
C
Characteristic Symbol
Test
Condition
Min.
Typ.
Max.
Unit
Collector-Base breakdown voltage
BV
CBO
I
C
=-10A, I
E
=0
-60 - - V
Collector-Emitter breakdown voltage
BV
CEO
I
C
=-1mA, I
B
=0 -50
-
-
V
Emitter-Base breakdown voltage
BV
EBO
I
E
=-10A, I
C
=0
-5 - - V
Collector cut-off current
I
CBO
V
CB
=-50V, I
E
=0 -
-
-10
nA
DC current gain
h
FE
V
CE
=-10V, I
C
=-10mA 100
-
-
-
Collector-Emitter saturation voltage
V
CE(sat)
I
C
=-150mA, I
B
=-15mA -
-
-0.4
V
Transistor frequency
f
T
V
CE
=-20V, I
C
=-20mA 200
-
-
MHz
Collector output capacitance
C
ob
V
CB
=-10V, I
E
=0, f=1MHz
-
6.0
-
pF
KST-9067-002
4
STN2907A
These AUK products are intended for usage in general electronic equipments(Office and
communication equipment, measuring equipment, domestic electrification, etc.).
Please make sure that you consult with us before you use these AUK products in equipm-
ents which require high quality and/or reliability, and in equipments which could have
major impact to the welfare of human life(atomic energy control, airplane, spaceship, traffic
signal, combustion central, all types of safety device, etc.).
AUK cannot accept liability to any damage which may occur in case these AUK products
were used in the mentioned equipments without prior consultation with AUK.