ChipFind - документация

Электронный компонент: 422LCOR

Скачать:  PDF   ZIP

Document Outline

Document No. 422LCOR4500 - pg. 1/2
B&B Electronics -- Revised November 2000
This product designed and manufactured in USA of domestic and imported parts by
RS-232 to RS-422 Converter
CE
CE
CE
CE
Model 422LCOR
This RS-232 to RS-422 converter converts unbalanced RS-232 signals to balanced
voltage digital interface to allow communications of 90K bits per second on cable lengths of 4000
feet. Ten receivers can be connected to any one driver for use in multi-drop systems.
The RS-232 port uses a female DB-25 type of connector with pins 2 (TD input) and 3 (RD output) supported. Protective
Ground (pin 1) and Signal Ground (pin 7) are also connected. The RS-422 port uses a male DB-25 type of connector with the Send
Data outputs on pins 2 and 14, and the Receive Data inputs on pins 5 and 17. Protective Ground (pin 1) and Signal Ground (pin 7) are
connected through to the RS-232 connector.
INTERCONNECTION OF THE CONVERTER WITH ANOTHER RS-422 DEVICE:
1.
The polarity of the two RS-422 lines must be correct. With no data being sent the RS-232 line should be negative and the
RS-422 "A" terminal should be negative with respect to the "B" terminal.
2.
The wire recommended in the RS-422 Standard is number 24 AWG copper conductor, twisted-pair telephone cable with a
shunt capacitance of 16 pF per foot.
3.
For long runs and/or high data rates it is recommended that the wires be terminated with a resistor at the receive end. The
twisted pair usually used has an impedance of about 100 ohms, therefore a 100 ohm resistor is normally used for the termination. The
RS-422 side of the converter requires more power as the transmission line is increased and as the termination resistor value is
reduced, therefore it may be necessary to use a termination resistor that is larger than 100 ohms.
4.
The RS-422 driver has the ability to drive 10 RS-422 receivers connected in parallel. A system of multiple receivers may
require some experimentation with location and size of termination resistors, line lengths, grounding, etc.
5.
The RS-422 Standard recommends that Protective Ground (pin 1) be connected to a good "green wire" ground. This may be
already connected in your RS-232 equipment. Protective Ground and Signal Ground should be connected to each other using a 100
ohm 1/2 watt resistor at one end only. If a shielded twisted pair is used the shield be connected to Protective Ground.
DECLARATION OF CONFORMITY
Manufacturer's Name:
B&B Electronics Manufacturing Company
Manufacturer's Address:
P.O. Box 1040
707 Dayton Road
Ottawa, IL 61350 USA
Model Numbers:
422LCOR
Description:
RS-232/422 Converter w/LEDs
Type:
Light industrial ITE equipment
Application of Council Directive: 89/336/EEC
Standards:
EN 50082-1 (IEC 801-2, IEC 801-3, IEC 801-4)
EN 50081-1 (EN 55022, IEC 1000-4-2)
EN 61000 (-4-2, -4-3, -4-4, -4-5, -4-6, -4-8, -4-11)
ENV 50204
EN 55024
Michael J. Fahrion, Director of Engineering
Document No. 422LCOR4500 - pg. 2/2
B&B Electronics -- Revised November 2000
This product designed and manufactured in USA of domestic and imported parts by