Specifications are subject to change without notice.
Features
I
Convenient kit for T1/E1 stations
I
Meets the T1 pulse mask as per ANSI
T1.403 and the E1 mask per ITU G.703
I
The protectors utilize PTC resistor
technology for automatic resetting
overcurrent protection and gas discharge
tube technology for overvoltage
protection
Model 1830-A T1/E1 Protection Assembly, Rail Mounted
Characteristics
Bourns Model 1830-A T1/E1 Protection Assemblies provide secondary overvoltage protection for multiple T1 or E1 lines.
DIN-3 Rail Mounted and able to accommodate future add-on modules, the assembly is designed to provide maximum surge
protection caused from direct and induced lightning surges, power line disturbances and ground potential rises.
Common installations of the 1830-A are power cabinets located in wireless base stations or other larger telecom service
entrance terminals.
Powered
Unpowered
Span
Span
Maximum System Voltage
Tip-Ring ........................................................................................................ 12 Vp-p ......................................... 12 Vp-p
Tip/Ring-Gnd ................................................................................................ 170 Vpk ........................................ 6 Vpk
DC Breakdown Rating @ <2000V/s (Tip-Ring-Gnd) .......................................... 6.5 Vdc ......................................... 15 Vdc
Impulse Voltage Rating @ 100V/ms (Tip/Ring-Gnd) .......................................... 475 Vpk ........................................ 20 Vpk
Peak Clamping Voltage (Tip-Ring)
14 A
1
10/1000
s ........................................................................................... 20 Vpk .......................................... 20 Vpk
1 kA 8/20
s ...................................................................................................30 Vpk .......................................... 30 Vpk
5 kA 8/20
s ...................................................................................................45 Vpk .......................................... 45 Vpk
Maximum Current, per line
@ 65
C ..........................................................................................................100 mA ......................................... 100 mA
@ 85
C ..........................................................................................................66 mA ........................................... 66 mA
Surge Life Tip/Ring-Gnd
14 A
1
10/1000
s .......................................................................................... 100 Operations ............................. 100 Operations
500 A
1
2/10
s ..............................................................................................1 Operation ................................... 1 Operation
100 A 10/1000
s .......................................................................................... 300 Operations ............................. 300 Operations
10 kA 8/20
s ................................................................................................ 10 Operations ............................... 10 Operations
20 kA 8/20
s ................................................................................................ 1 Operation ................................... 1 Operation
Pulse Mask
ANSI T1.403(1.544 Mbits/s) .......................................................................... Complies ...................................... Complies
CCITT G.703 (2.048 Mbits/s) ........................................................................ Complies ...................................... Complies
Data Attenuation
1.544 Mbits/s ................................................................................................ 0.6 dB ........................................... 0.6 dB
2.048 Mbits/s ................................................................................................ 1.4 dB ........................................... 1.4 dB
Capacitance @ 1.0 MHz, Tip-Ring ..................................................................... <75 pF .......................................... <75 pF
Series Resistance, per line ................................................................................. 10
.............................................. 10
Operating Temperature ...................................................................................... -40
C to +85C ............................. -40C to +85C
Response Time .................................................................................................. < 1 ns ............................................ < 1 ns
Wire Size, Input and Output ............................................................................... AWG 14 22 ................................ AWG 14 22
Warranty ............................................................................................................. 1 Year ............................................ 1 Year
1
applies to model 1830
REV. A
I
Both protectors can be on-site configured
for either powered or unpowered spans
I
Simplicity of DIN-3 rail mounting; the rail
also serves as protector ground
I
Vibration proof screw-type clamping
connector interface
Asia-Pacific:
TEL +886- (0)2 25624117 FAX +886- (0)2 25624116
Europe:
TEL +41-41 7685555 FAX +41-41 7685510
North America:
TEL +1-909 781-5500 FAX +1-909 781-5700
bourns.com
COPYRIGHT 2001, BOURNS, INC. LITHO IN U.S.A. IP 09/01 G0133
Specifications are subject to change without notice.
MM
(INCHES)
DIMENSIONS:
Example: 1830-A261
How To Order
Model Number Designator
Number of Protected T1 Lines
1
1 = One line (two protectors)
2 = Two lines (four protectors)
3 = Three lines (six protectors)
4 = Four lines (eight protectors)
5 = Five lines (ten protectors)
Rail Length
1 = 2.8" long - Accommodates one pair of protectors without ground wire clamp
2 = 4.2" long - Accommodates one pair of protectors with ground wire clamp
3 = 5.6" long - Accommodates two pair of protectors with ground wire clamp
4 = 7.0" long - Accommodates three pair of protectors with ground wire clamp
5 = 8.4" long - Accommodates four pair of protectors with ground wire clamp
6 = 9.8" long - Accommodates five pair of protectors with ground wire clamp
Without ground wire clamp, use next shorter rail.
For smaller spaces, use next shorter rail.
(Rail mounting screw heads will be partially hidden under clamps.)
Ground Wire Clamp and 24" AWG #12 Insulated Ground Wire
0 = Without clamp and wire
1 = With clamp and wire
Notes:
1
Two protectors are required for each T1 line, one for transmit and one for receive.
Slots in rail are .21" wide; will accomodate #10 screw. Drill enlarge for bigger screw.
1830-A X X X
Model 1830-A T1/E1 Protection Assembly, Rail Mounted
Product Dimensions
UNPOWERED
POWERED
SP
AN
TIP
RING
TIP
RING
UNPOWERED
POWERED
SP
AN
TIP
RING
TIP
RING
UNPOWERED
POWERED
SP
AN
TIP
RING
TIP
RING
UNPOWERED
POWERED
SP
AN
TIP
RING
TIP
RING
83.0
(3.3)
48.0
(1.9)
45.72
(1.8)
18.80
(.74)