ChipFind - документация

Электронный компонент: KX500-F3A

Скачать:  PDF   ZIP
KX500 8/99 REV B
Page 1
DESCRIPTION
The KX500 is a compact 500 watt Power Factor Corrected, multiple
output power supply. All outputs are fully isolated and regulated.
The main +5V output delivers 80A with remote sensing. Five
outputs allow this one power supply to fill all system voltage
requirements, including fan and disk drive applications. Both
Power Fail Warning and DC OK signals are standard features as
well as Remote Inhibit.
FEATURES
!
!
!
!
! Active Power Factor Correction to EN61000-3-2
!
!
!
!
! High Current Auxiliary Outputs
!
!
!
!
! FCC/CISPR Class B EMI Filter
!
!
!
!
! Fully Isolated Outputs
!
!
!
!
! Compact Size: 10" x 5.0" x 2.0"
!
!
!
!
! Three and Five Output Models
!
!
!
!
! Optional Fan Mounted On Cover
!
!
!
!
! Remote Inhibit
!
!
!
!
! DC OK Signal
!
!
!
!
! Power Fail Warning
!
!
!
!
! UL/CSA/TUV Approved
!
!
!
!
! CE Mark
500 W
ATT
AC/DC P
OWER
S
UPPLY
Product Data Sheet
KX500
Internet: http://www.cdpowerelectronics.com
Power Electronics Division, United States
3400 E Britannia Drive, Tucson, Arizona 85706
Phone: 800.547.2537 Fax: 520.770.9369
Power Electronics Division, Europe
C&D Technologies (Power Electronics) Ltd.
132 Shannon Industrial Estate, Shannon, Co. Clare, Ireland
Tel: +353.61.474.133 Fax:+353.61.474.141
AGENCY APPROVALS
KX500 8/99 REV B
Page 2
Remote Sense
Remote Sense is provided on Output #1 and will
compensate for 0.3V of line drop. Remote Sense leads
are protected against open, short, and reversal.
Remote On/Off
The power supply is turned on with a TTL logic level `1' (or
open) signal and turned off by a switch closure or TTL logic
level `0' referenced to (-) sense terminal. Consult the factory
for other options.
Over Voltage Protection
Output #1: 6.25V, 0.75 V
DC
.
Output #2: 14.0V 1V
DC
. (Output #2 12V)
17.0V 1V
DC
. (Output #2 15V)
The power supply will latch off until AC power is cycled.
Over Current Protection
Individual current limit on all outputs. Automatic recovery
upon fault removal.
Reverse Voltage Protection
All outputs are protected to rated load.
Transient Response
The peak output voltage excursion on the main output will
not exceed 2% and will recover within 1% in 50 mSec for a
25% load step change. On outputs #2-5, the peak output
voltage excursion will not exceed 1% for a 25% load step
change.
Output Isolation
All outputs are fully isolated.
Power Fail Signal
Upon AC input voltage removal, the power fail signal drops
to logic level `0' at least 5msec before loss of DC output.
Upon AC input turn-on, signal remains low until outputs are
in regulation. Consult the factory for other options.
DC Power Good Signal
The signal drops to logic level `0' by a 10% loss of regulation
on any output, common with Output #1 (-) sense. Consult
the factory for other options.
Over Temperature Protection
Internal thermal switch turns off power supply if overheating
occurs and automatically restarts. Automatic restart when
temperature drops below threshold.
Safety
UL Recognized: UL File Number 14675 (1950 & 1012)
CSA Certified: CSA File Number LR9070-154C
(C22.2 No. 234-M90, Level 6)
TUV License Number:R9576025 (EN60950) (IEC950)
Cooling
The unit is designed to operate with 30 CFM of airflow.
Input Specifications
Parameter
Conditions
Min
Typ
Max
Units
Operating Range
47-63Hz
90
264
V
AC
Inrush Current
120V
AC,
cold start at 25C
40
A
PK
240V
AC,
cold start at 25C
80
A
PK
Efficiency
Nominal line and full load
75
%
Power Factor*
0.99
*Harmonic Correction meets IEC 1000-3-2 (formerly IEC 555-2)
The information provided herein is believed to be reliable; however, C&D TECHNOLOGIES assumes no responsibility for inaccuracies or omissions. C&D TECHNOLOGIES
assumes no responsibility for the use of this information, and all use of such information shall be entirely at the user's own risk. Prices and specifications are subject to
change without notice. No patent rights or licenses to any of the circuits described herein are implied or granted to any third party. C&D TECHNOLOGIES does not authorize
or warrant any C&D TECHNOLOGIES product for use in life support devices/systems or in aircraft control applications.
KX500 8/99 REV B
Page 3
Output Voltages and Maximum Rated Loads
OUTPUT #1
OUTPUT #2
OUTPUT #3
OUTPUT #4
OUTPUT #5
MODEL NUMBER
V
OUT
I
MAX
V
NOM
I
MAX
V
NOM
I
MAX
V
NOM
I
MAX
V
OUT
I
MAX
KX500-F3A
5V
80A
12V
20A
12V
20A
-
-
-
-
KX500-F3B
5V
80A
15V
20A
15V
20A
-
-
-
-
KX500-F5C
5V
80A
12V
20A
12V
20A
24V
3A
5V
6A
KX500-F5D
5V
80A
12V
20A
12V
20A
12V
6A
5V
6A
KX500-F5E
5V
80A
15V
20A
15V
20A
24V
3A
5V
6A
KX500-F5F
5V
80A
15V
20A
15V
20A
12V
6A
5V
6A
KX500-F5G
5V
80A
15V
20A
15V
20A
5V
6A
5V
6A
Note: Maximum current ratings are for 10sec maximum. Total power not to exceed 500 watts.
Output Specifications
Parameter
Limits
Regulation
Main Output Outputs #2 - 5
Line
0.1% 0.2%
Load
0.2% 0.4%
Cross
0.2% 0.2%
Minimum Load
Output #1
5.0A
Outputs#2 & #3
1.0A
Outputs #4 & #5
0.0A
Hold-Up Time
20mSec at Full Load
Output #4 (24V)
0.5%
0.4%
0.5%
Parameter
Conditions
Min
Typ
Max
Units
Voltage Adustment Range
Nominal line on all outputs
5
%
PARD
20 MHz bandwidth
1
% P-P or
100mV P-P
whichever is smaller
Temperature
Operating
300 CFM airflow, all line & load conditions
0
40
C
Derates 10W/C
40
60
C
Derates 20W/C
60
70
C
Storage
-20
+70
C
Humidity Range
Non-condensing
0
95
%
Temperature Coefficient (T
C
)
After half hour warm-up
0.02
%/C
Output #4 with 24V option
0.11
%/C
KX500 8/99 REV B
Page 4
Standard Options are shown, consult factory for other available options.
TOP VIEW
NOTES:
All measurements are in inches
FAN MOUNTED ON COVER ADDS 1.80". A 1.3" FAN IS ALSO AVAILABLE.
COOLING: The KX500 is designed to operate with 30 CFM airflow.
SHOCK AND VIBRATION: The KX500 meets the requirements of MIL STD-810D. (Vibration-Method 514.3 Procedure I; Shock-Method 516.3 Procedure I).
WEIGHT: Approximately 5 lbs.
Terminal Block 1
Terminal Block 2
POS
FUNCTION
POS
FUNCTION
1
AC Line
1
+V4
2
AC Neutral
2
-V4
3
Ground
3
+V5
4
-V5
5
+V3
6
-V3
7
+V2
8
-V2 & -FAN
9
+ FAN OUTPUT
J3 Connector
J3 Connector
PIN
FUNCTION
Molex No.
1
+ Sense
Connector
22-05-3021
2
- Sense
1
AC Power Good
Molex No.
2
Signal Common
Connector
22-28-1050
3
DC Power Good
4
Remote Inhibit
5
Remote Inhibit Rtn.
Pin Specifications
Connector Specifications
J5 Connector
J5 Connector
Mechanical
F
AN CO
VER
Model Number Specification
KX500 -
*
B
*
L
H
H
N
Base Model
Output Voltage
Configuration (see
table on pg. 3 for options)
"B" denotes Class B EMI
compliance (standard feature)
Cover Options: C denotes plain cover;
F denotes cover w/integral fan
N denotes no cover
N denotes no
active current
sharing available
H denotes that a logic level "1"
indicates DC OK (transition
to "0" on loss of output regulation)
H denotes that a logic level "1"
indicates AC present.
(transition to "0" on loss of AC power)
L denotes that a logic level "1' (or open) enables the
power supply (short to signal common - or -sense
inhibits the output)