ChipFind - документация

Электронный компонент: NTV1209M-R

Скачать:  PDF   ZIP
SELECTION GUIDE
FEATURES
s
3kVDC Isolation (1 Minute)
s
Wide Temperature Performance at
Full 1 Watt Load, -40C to 85C
s
Lead Frame Technology
s
CECC00802 Reflow (280C)
s
Dual Isolated Output
s
Efficiency to 82%
s
Power Density 1.5W/cm
3
s
5V & 12V Input
s
5V, 9V, 12V and 15V Output
s
Footprint Over Pins 1.64cm
2
s
UL 94V-0 Package Material
s
No Heatsink Required
s
Internal SMD Construction
s
Toroidal Magnetics
s
Plastic Encapsulated
s
MTTF up to 2.1 Million Hours
s
Custom Solutions Available
s
Multi Layer Ceramic Capacitors
s
Lead Free Compatibility
s
Tape and Reel Option
DESCRIPTION
The NTV series of 3kV isolation miniature
surface mounted DC-DC Converters employ
leadframe technology and transfer moulding
techniques to bring all of the benefits of IC
style packaging to hybrid circuitr y. The
devices are fully compatible with
CECC00802 to 280C which allows them to
be placed and reflowed with IC's, thus
reducing time and cost in production. The co-
planarity of the pin positions is based upon
IEC 191-6:1990. The devices are suitable for
all applications where high volume
production is envisaged.
Nominal
Input
Input
Output
Output
Current at
Isolation
Voltage
Voltage
Current
Rated Load Efficiency
Capacitance MTTF
1
O rd e rC o d e
5
(V)
(V)
(mA)
(mA)
(%)
(pF)
kHrs
NTV0505M
5
5
100
282
71
33
1697
NTV0509M
5
9
55
260
77
38
682
NTV0512M
5
12
42
253
79
44
343
NTV0515M
5
15
33
250
80
43
188
NTV1205M
12
5
100
114
73
50
559
NTV1209M
12
9
55
105
79
72
375
NTV1212M
12
12
42
104
80
89
243
NTV1215M
12
15
33
101
82
100
154
When operated with additional external load capacitance the rise time of the input voltage will determine the
maximum external capacitance value for guaranteed start up. The slower the rise time of the input voltage the
greater the maximum value of the additional external capacitance for reliable start up.
1 Calculated using MIL-HDBK-217F with nominal input voltage at full load.
2 See derating curve.
3 12V input types have typically 3% less load regulation change.
4 Supply voltage must be discontinued at the end of the short circuit duration.
5 If components are required in tape and reel format suffix order code with -R, e.g. NTV0505M-R.
All specifications typical at T
A
=25C, nominal input voltage and rated output current unless otherwise specified.
Parameter
Conditions
MIN
TYP
MAX
Units
Voltage Range
Continuous operation, 5V input types
4.5
5
5.5
V
Continuous operation, 12V input types 10.8
12
13.2
Reflected Ripple Current
41
47
mA p-p
Short circuit duration
4
1second
Internal power dissipation
550mW
Lead temperature 1.5mm from case for 10 seconds
300C
Input Voltage V
IN
, NTV05 types
7V
Input voltage V
IN
, NTV12 types
15V
INPUT CHARACTERISTICS
ABSOLUTE MAXIMUM RATINGS
Parameter
Conditions
MIN
TYP
MAX
Units
Rated Power
2
T
A
= -40C to 85C
1.0
W
Voltage Set Point
Accuracy
See tolerance envelope
Line regulation
High V
IN
to low V
IN
1.0
1.2
%/%
Load Regulation
3
10% load to rated load, 5V output types
10
12
%
10% load to rated load, 9V output types
6.5
8.0
10% load to rated load, 12V output types
6.0
8.5
10% load to rated load, 15V output types
6.0
7.0
Ripple and Noise
BW=DC to 20MHz, 5V output types
50
75
mV p-p
BW=DC to 20MHz, 9V output types
40
65
BW=DC to 20MHz, 12V output types
40
60
BW=DC to 20MHz, 15V output types
40
60
OUTPUT CHARACTERISTICS
NTV SERIES
3kVDC Isolated 1W Dual Output SM DC-DC Converters
www.dc-dc.com
NTV SERIES
3kVDC Isolated 1W Dual Output SM DC-DC Converters
C&D Technologies (NCL) Ltd
Tanners Drive, Blakelands North
Milton Keynes MK14 5BU, England
Tel: +44 (0)1908 615232
Fax:+44 (0)1908 617545
email: info@cdtechno-ncl.com
www: http://www.dc-dc.com
C&D Technologies (NCL), Inc.
5816 Creedmoor Road, Raleigh
NC 27612, USA
Tel: +1 (919) 571-9405
Fax: +1 (919) 571-9262
email: info@us.cdtechno-ncl.com
C&D Technologies (NCL) Limited reserve the right to alter or improve the
specification, internal design or manufacturing process at any time, without
notice. Please check with your supplier or visit our web site to ensure that
you have the current and complete specification for your product before use.
C&D Technologies (NCL) Limited 2001
NDC NTV.3
No part of this publication may be copied, transmitted or stored in a
retrieval system or reproduced in any way including, but not limited to,
photography, photocopy, magnetic or other recording means, without prior
written permission from C&D Technologies (NCL) Limited.
Instructions for use are available from www.dc-dc.com
ISOLATION CHARACTERISTICS
GENERAL CHARACTERISTICS
TEMPERATURE CHARACTERISTICS
PERFORMANCE CHARACTERISTICS
Parameter
Conditions
MIN
TYP
MAX
Units
Isolation Test Voltage
For 1 Minute
3000
VDC
Resistance
Viso=1000VDC
10
G
Parameter
Conditions
MIN
TYP
MAX
Units
Switching Frequency
5V input types
115
kHz
12V input types
115
Parameter
Conditions
MIN
TYP
MAX
Units
Specification
All output types
-40
85
C
Storage
-55
125
C
Case Temperature
5V output types
46
C
above ambient
All other output types
35
Cooling
Free air convection
tolerance envelope
+
10%
+5%
V nominal
temperature derating graph
2.0
1.5
1.0
0.5
0
+2.5%
-2.5%
-7.5%
MECHANICAL DIMENSIONS
10
50
100
Output Load Current (%)
-40
0
50
100
150
Ambient Temperature (C)
85C
Safe Operating Area
PIN
1
GND
3
V
IN
5
NA
9
0V
11
-V
12
NA
14
+V
18
NA
20
NA
22
NA
We i g h t: 1. 5 3g
For tape and reeling packaging details refer to datasheet NDCAN002.1
All dimensions in mm XX.XX 0.25mm. All pins on a 2.54mm pitch.
15.24
12.70
11.20
10.40
6.60
(5.95)
(6.35)
5.85
0.65
0.55
0.30
0.20
1.875
MAX
DETAIL A
DETAIL A
1.50
1.20
7.70
2.54
2.10
0.5
REFERENCE
PLANE
5.00
0.25
0.10
2.79MAX
1
3
5
9
11
12
14
22
18
20
0.1 S
NTV0505M
XYYWW
0.2
M
P
S
P
10 PINS
SEATING PLANE
S