DESCRIPTION
The PX401 is a compact 400 watt Power Factor Corrected,
multiple output power supply. All outputs are fully isolated
and regulated. Active current sharing circuitry, together with
control functions and alarm options, simplifies N+1 and
redundant applications. Fan and disk drive applications are
handled by the peak current ratings of the auxiliary outputs.
!
!
!
!
! Active Power Factor Correction
!
!
!
!
! High Surge Current Auxiliary Outputs
!
!
!
!
! FCC/VDE Class B EMI Filter
!
!
!
!
! Fully Isolated and Regulated Outputs
!
!
!
!
! Compact Size: 10" x 4.85" x 2.19"
!
!
!
!
! One, Two, Three and Four Output Models
!
!
!
!
! Optional Cover With Fan
FEATURES
400 W
ATT
AC/DC P
OWER
S
UPPLY
Product Data Sheet
PX401/403
AGENCY APPROVALS
Internet: http://www.cdpowerelectronics.com
Power Electronics Division, United States
3400 E Britannia Drive, Tucson, Arizona 85706
Phone: 800.547.2537 Fax: 520.770.9369
Power Electronics Division, Europe
C&D Technologies (Power Electronics) Ltd.
132 Shannon Industrial Estate, Shannon, Co. Clare, Ireland
Tel: +353.61.474.133 Fax:+353.61.474.141
PX401 4/98 REV B
Page 2
Input Specifications
Parameter
Conditions
Min
Typ
Max
Units
Operating Range
47-63 Hz
90
264
V
AC
Inrush Current Limiting
120 V
AC,
cold start
30
A
PK
240 V
AC
, cold start
60
A
PK
Efficiency
Nominal line and full load
75
%
Power Factor Correction (PFC)
0.99
Meets IEC 1000-4-7/EN61000-3-2 (formerly IEC 555-2)
Remote Sense
Remote Sense is provided on Output #1 and will
compensate for 1.0V of line drop. Remote Sense leads are
protected against open, short and reversal.
Remote On/Off
The power supply is turned on with a TTL logic `1' (or open)
signal and turned off by a switch closure or TTL logic `0'
referenced to (-) sense terminal. Consult the factory for other
options.
Over Voltage Protection
Output #1: 6.5V, 0.5 V
DC
The power supply will latch off until AC power is cycled.
Over Current Protection
Individual current limit on all outputs. Automatic recovery
upon fault removal.
Transient Response
The peak output voltage excursion will not exceed 2% and
will recover within 1% in 200
sec for a 25% step load.
Output Isolation
All outputs are fully isolated.
Reverse Voltage Protection
All outputs are protected to rated load current.
Power Fail Signal
Upon AC input voltage removal, the power fail signal drops
to logic zero at least 10msec before loss of DC output.
Upon AC input turn-on, signal remains low until outputs are
in regulation. Consult the factory for other options.
N+1 Load Share (PX403)
Output #1 has active load sharing circuitry. Units will load
share within 1% of Maximum Rated Load.
Over Temperature Protection
Thermal switch turns off power supply if overheating occurs
and automatically restarts.
Safety
UL Recognized: UL File Number E14675 (1950 & 1012)
CSA Certified:
CSA File Number LR 9070-154C
(C22.2 No9. 234-M90, Level 6)
TUV License Number: R9576029 (EN60950) (IEC950)
Cooling
The unit is designed to operate with 40 CFM airflow.
PX401 4/98 REV B
Page 3
Output Voltages and Maximum Rated Loads
OUTPUT #1
OUTPUT #2
OUTPUT #3
OUTPUT #4
MODEL NUMBER
V
OUT
I
MAX
V
NOM
I
MAX
/I
PK
V
NOM
I
MAX
/I
PK
V
NOM
I
MAX
PX401/403-U3A
5V
50A
12V
12A/14A
12V
12A/14A
-
-
PX401/403-U3B
5V
50A
15V
12A/14A
15V
12A/14A
-
-
PX401/403-U4C
5V
50A
12V
10A/12A
12V
10A/12A
5V
3.0A
PX401/403-U4D
5V
50A
12V
10A/12A
12V
10A/12A
24V
2.0A
PX401/403-U4E
5V
50A
12V
10A/12A
12V
10A/12A
12V
3.0A
PX401/403-U4F
5V
50A
15V
10A/12A
15V
10A/12A
5V
3.0A
PX401/403-U4G
5V
50A
15V
10A/12A
15V
10A/12A
24V
2.0A
PX401/403-U4H
5V
50A
12V
10A/12A
12V
10A/12A
5.2V
10.0A
PX401/403-U4I
5V
50A
15V
10A
15V
10A
5.2V
10.0A
PX401/403-U4J
5V
20A
17V
3A
17V
3A
24V
10.0A
PX401/403-U4K
5V
25A
12V
10A
12V
10A
12V
4.0A
PX401/403-U4L
5V
30A
12V
10A
12V
10A
5.2V
3.0A
PX401/403-U4M
5V
30A
15V
12A
15V
12A
5.2V
10.0A
PX401/403-U4N
5V
70A
12V
12A
12V
12A
3.3V
10.0A
PX401/403-U4P
5V
30A
12V
10A
12V
12A
24V
3.0A
PX401/403-U4R
5V
20A
15V
4A
15V
4A
24V
10.0A
PX401/403-U4S
5V
20A
12V
8A
12V
3A
24V
10.0A
Output Specifications
Parameter
Limits
Regulation
Line
0.1%
Load
0.5%
Cross
0.1%
Minimum Load
Output #1
2.5A
Hold-Up Time
30mSec at Full Load
Parameter
Conditions
Min
Typ
Max
Units
Voltage Adustment Range
5
%
PARD
20 MHz bandwidth
0.5
% P-P
Temperature
Operating
0
50
C
Storage
-20
+85
C
Temperature Coefficient (T
C
)
After half hour warm-up
0.02
%/C
Note: Peak current ratings are for 10sec maximum. Total power not to exceed 400 watts.
PX401 4/98 REV B
Page 4
Model PX403 features Active Current Sharing
Standard Options are shown, consult factory for other available options.
Pin Specifications
Terminal Block 1
Terminal Block 2
POS
FUNCTION
POS
FUNCTION
1
Ground
1
-V4
2
AC Neutral
2
+V4
3
AC Line
3
-V3
4
+V3
5
-V2
6
+V2
The information provided herein is believed to be reliable; however, C&D Technologies assumes no responsibility for inaccuracies or omissions. C&D Technologies assumes
no responsibility for the use of this information, and all use of such information shall be entirely at the user's own risk. Prices and specifications are subject to change without
notice. No patent rights or licenses to any of the circuits described herein are implied or granted to any third party. C&D Technologies does not authorize or warrant any C&D
Mechanical
0.700
0.550
3.900
10.000
8.500
2.148
4.850
0,040
COVER
TB1
Maximum depth of mounting screws is 0.156"
TB2
5V
5V Return
J9
TOP VIEW
1
2
3
1
2
3
4
5
6
NOTES: All measurements are in inches
FAN MOUNTED ON COVER ADDS 1.30".
COOLING: The PX401/403 is designed to operate with 40 CFM airflow.
SHOCK AND VIBRATION: The PX401/403 family meets the requirements of MIL STD-810D. D(Vibration-Method 514.3 Procedure I; Shock-Method 516.3
Proedure I).
WEIGHT: Approximately 4 lbs.
J9 Connector
J9 Connector
PIN
FUNCTION
Molex No.
1
- Sense
Connector
22-28-1050
2
+ Sense
3
Current Share
4
Remote Inhibit
5
Power Fail
Connector Specifications