ChipFind - документация

Электронный компонент: A201120600

Скачать:  PDF   ZIP
Specifications are subject to change without notice (25.10.99)
1
Time ranges
0.15-
6 s
1.5 - 60 s
15
- 600 s
Time range accuracy
0 to +10% on max.
min. actual time
min.
set time
Timers
Mono-function, plug-in, de-
lay on operate miniature time
relays up to 600 s (10 min)
covering 3 individual time
ranges. These economical
relays can be used to pre-
vent several motors from
starting simultaneously due
to power supply interruptions.
Repeatability deviation
1%
Time variation
Within rated power supply
0.05%/V
and ambient temperature
0.2%/C
Reset
Power supply interruption
Time and/or relay
250 ms
Function
Output
Type
Power supply
Time range
Time ranges: 0.15 s to 600 s
Automatic start
Knob-adjustable time within range
Oscillator-controlled time circuit
Repeatability deviation:
1%
Output: 10 A SPDT or 8 A DPDT relay
Plug-in type module
Scantimer housing
LED-indication for relay on
AC or DC power supply
Delay on Operate
Types A 108, A 101, A 208, A 201
Plug
Output
Time ranges
Supply: 24 VAC/DC
Supply: 120 VAC
Supply: 220 VAC
Circular
SPDT
0.15-
6 s
A 108 024 006
A 108 120 006
A 108 220 006
8 pin
1.5 - 60 s
A 108 024 060
A 108 120 060
A 108 220 060
15
-600 s
A 108 024 600
A 108 120 600
A 108 220 600
Circular
0.15-
6 s
A 101 024 006
A 101 120 006
A 101 220 006
11 pin
1.5 - 60 s
A 101 024 060
A 101 120 060
A 101 220 060
15
-600 s
A 101 024 600
A 101 120 600
A 101 220 600
Circular
DPDT
0.15-
6 s
A 208 024 006
A 208 120 006
A 208 220 006
8 pin
1.5 - 60 s
A 208 024 060
A 208 120 060
A 208 220 060
15
-600 s
A 208 024 600
A 208 120 600
A 208 220 600
Circular
0.15-
6 s
A 201 024 006
A 201 120 006
A 201 220 006
11 pin
1.5 - 60 s
A 201 024 060
A 201 120 060
A 201 220 060
15
-600 s
A 201 024 600
A 201 120 600
A 201 220 600
Ordering Key
Product Description
Type Selection
Time Specifications
A 108 024 600
2
Specifications are subject to change without notice (25.10.99)
A 108, A 101, A 208, A 201
A 108, A 101
A 208, A 201
Output
SPDT relay
DPDT relay
Basic electrical insulation
250 VAC (rms) (contact/electronics)
250 VAC (rms) (contacts/elec., contact/contact)
Contact ratings (Ag-CdO)
(micro gap)
(micro gap)
Resistive loads
AC 1
10 A/250 VAC (2500 VA)
8 A/250 VAC (2000 VA)
DC 1
1 A/250 VDC (250 W)
0.4 A/250 VDC (100 W)
or
10 A/25 VDC (250 W)
4 A/25 VDC (100 W)
Small inductive loads
AC 15 2.5 A/230 VAC
2.5 A/230 VAC
DC 13 5 A/24 VDC
5 A/24 VDC
Mechanical life
30 x 10
6
operations
30 x 10
6
operations
Electrical life
AC 1
2.5 x 10
5
operations (at max. load)
2.5 x 10
5
operations (at max. load)
Operating frequency
7200 operations/h
7200 operations/h
Insulation voltages
Rated insulation voltage
2.0 kVAC (rms) (contact/electronics)
2.0 kVAC (rms) (contact/electronics)
Rated transient protection volt. 4 kV (1.2/50 s) (contact/electronics) (IEC 60664)
4 kV (1.2/50 s) (contact/electronics) (IEC 60664)
Power supply
A 101, A 201
Power-on delay
200 ms
Power-off delay
250 ms
Indication for
Output ON
LED, red
Environment
IP 20 B
Polution degree
2 (IEC 60664)
Operating temperature
-20 to +50C (-4 to +122F)
Storage temperature
-50 to +85C (-58 to +185F)
Weight
85 g
Approvals
UL, CSA
Power supply AC types
installation cat. III (IEC 60664)
Rated operational voltage
through pins 2 & 10
220
220 VAC + 15/- 20%,
or pins 2 & 7
45 to 65 Hz
120
120 VAC + 15/- 20%,
45 to 65 Hz
024
24 VAC + 15/- 20%,
45 to 65 Hz
Drop out tolerance
10 ms
Rated insulation voltage
None
Rated transient protection volt. 4 kV (1.2/50 s) @ 220 VAC
2.5 kV (1.2/50 s) @ 120 VAC
800 V (1.2/50 s) @ 24 VAC
(line/neutral)
Power supply DC type
Installation cat. III (IEC 60664)
Rated operational voltage 024
24 VDC + 15/- 20% (pin 2 pos.)
Rated insulation voltage
None
Rated transient protection volt. 800 V (1.2/50 s)
Consumption
AC supply
60 mA @ 50 Hz/70 mA @ 60 Hz
DC supply
1 W
Mode of Operation
The delay period begins when
power supply is applied.
At the end of the set delay,
the relay will operate and will
not release until power sup-
ply is interrupted.
A recovery period of 250 ms
should be allowed before re-
applying power supply.
If power supply is interrupted
for more than 250 ms before
the relay operates, the time
circuit is reset to zero and the
time relay is ready for a new
time period.
Wiring Diagrams
Output Specifications
Supply Specifications
General Specifications
Power supply
A 108, A 208
Specifications are subject to change without notice (25.10.99)
3
A 108, A 101, A 208, A 201
Knob-adjustable on scale in
seconds.
Power supply
Relay on
Sockets
S 408, S 411
Hold down spring
HF
Mounting rack
SM 13
Socket cover
BB4
Potentiometer lock
PL 1
For further information refer to "Accessories".
Time Setting
Accessories
Operation Diagram