ChipFind - документация

Электронный компонент: CA18CLC20BP

Скачать:  PDF   ZIP
Specifications are subject to change without notice (21.11.03)
1
Housing diameter
Rated operating distance
Ordering no.
Ordering no.
(S
n
)
Cable
Plug
M18
12 mm
CA18CLC12BP
CA18CLC12BPM1
M 30
30 mm
CA30CLC30BP
CA30CLC30BPM1
Ordering Key
Product Description
Proximity Sensors Capacitive
Thermoplastic Polyester Housing
Types CA, M18, M30, DC, Teach-in
Featuring
TRIPLESHIELDTM Sensor Protection
Sensing distance: 0.5 - 12 mm (M18) and
1.0 - 30 mm (M30)
Teach-in of sensing distance via push-button or
COM-input
Automatic detection of NPN or PNP load
Selectable make or break switching by means of
Teach-in function
Protection: Short-circuit, transients and reverse polarity
Humidity compensation
Alarm output
5 years of warranty
On request: Delay on output. New line autotune to
compensate for heavy dirt build-up
Capacitive proximity switch
Housing diameter (mm)
Housing material
Housing length
Detection principle
Rated operating dist. (mm)
Output type
Output configuration
Connection type
Type Selection
Capacitive proximity switch-
es with a sensing distance
of either 8 mm flush mount-
ed in metal or 12 mm non-
flush mounted for the M18
version, and either 16 mm
flush mounted in metal or 30
mm non-flush mounted for
the M30 version. The
switching points can be
altered by means of the
Teach-in function. 3-wire DC
output with selectable make
(NO) or break (NC) switching
and NPN Alarm. Grey
polyester housing with 2 m
PVC cable or M12 plug.
TRIPLESHIELD
TM
CA18CLC12BPM1
Sensing range (S
d
)
CA18CLC12
0.5 - 12 mm
factory set at 8 mm
CA30CLC30
1.0 - 30 mm
factory set at 15 mm
Sensitivity
Adjustable (Teach-in)
Effective operating dist. (S
r
)
0.9 x S
n
S
r
1.1 x S
n
Usable operating dist. (S
u
)
0.8 x S
r
S
u
1.2 x S
r
Repeat accuracy (R)
5%
Hysteresis (H)
Depending on Teach-in
Rated operational volt. (U
B
)
10 to 40 VDC (ripple incl.)
Ripple
10%
Rated operational current (I
e
) 250 mA (continuous)
No-load supply current (I
o
)
12 mA
Voltage drop (U
d
)
2.5 VDC @ max. load
Protection
Short-circuit, reverse
polarity, transients
TRIPLESHIELD
TM
protection-EMC
IEC 1000-4-2/EN 61000-4-2
30 kV
IEC 1000-4-3/EN 61000-4-3
> 15 V/m
IEC 1000-4-4/EN 61000-4-4
3 kV
IEC 1000-4-6/EN 61000-4-6
> 10 V
rms
Frequency of operating
cycles
(f)
15 Hz
Indication
For output ON
LED, yellow
For safe/unsafe
LED, green
Environment
Degree of protection
IP 68
Operating temperature
-20 to +85C ( -4 to +185F)
Storage temperature
-40 to +85C (-40 to +176F)
Housing material
Body
Grey, thermoplastic polyester
Cable end
Polyester, softened
Nuts
Black, PA12 Grilamid
Connection
Cable
Grey, 2 m, 4 x 0.25 mm
2
Oil proof, PVC
Plug (M1)
M12 x 1
Cable for plug (M1)
CON.1A-series
Weight
Cable version - M18 / M30
110 g/160 g
Plug version - M18 / M 30
30 g/70 g
Approvals
UL, CSA
CE-marking
Yes
Specifications
2
Specifications are subject to change without notice (21.11.03)
CA, M18, M30, DC, Teach-in
The environments in which
capacitive sensors are install-
ed can often be unstable re-
garding temperature, humidity,
object distance and industrial
(noise) interference. Because
of this, Carlo Gavazzi offers
as standard features in all
TRIPLESHIELDTM capacitive
sensors a user-friendly sensi-
tivity adjustment instead of
having a fixed sensing range,
extended sensing range to
accommodate mechanically
demanding areas, temperature
stability to ensure minimum
need for adjusting sensitivity if
temperature varies and high
immunity to electromagnetic
interference (EMI).
Note:
Sensors are factory set
(default) to nominal sensing
range S
n
.
Adjustment Guide
Installation Hints
Capacitive sensors have the
unique ability to detect al-
most all materials, either in li-
quid or solid form. Capacitive
sensors can detect metallic
as well as non-metallic ob-
jects, however, their tradition-
al use is for non-metallic
materials such as:
Plastics Industry
Resins, regrinds or mould-
ed products.
Chemical Industry
Cleansers, fertilisers, liquid
soaps, corrosives and pe-
trochemicals.
Wood Industry
Saw dust, paper products,
door and window frames.
Ceramic & Glass
Industry
Raw material, clay or
finished products, bottles.
Packaging Industry
Package inspection for level
or contents, dry goods,
fruits and vegetables, dairy
products.
Materials are detected due to
their dielectric constant. The
bigger the size of an object,
the higher the density of ma-
terial, the better or easier it is
to detect the object. Nominal
sensing distance for a capaci-
tive sensor is referenced to a
grounded metal plate (ST37).
For additional information
regarding dielectric ratings
of materials please refer to
Technical Information.
Dimensions
Relief of cable strain
Protection of the sensing face
Switch mounted on mobile carrier
To avoid interference from inductive voltage/
current peaks, separate the prox. switch pow-
er cables from any other power cables, e.g.
motor, contactor or solenoid cables
Not correct
Correct
The cable should not be pulled
A proximity switch should not serve as
mechanical stop
Any repetitive flexing of the
cable should be avoided
Plug
Cable
Plug
Cable
Delivery Contents
Capacitive switch: CA..CLC..BP..
Packaging: Cardboard box
Installation & Adjustment Guide (MAN CAP ENG/GER)
Accessories
Plugs CON.1A.. series.
For further information please refer to "Accessories.
CA18
CA30
89.2
89.2
50
50
23
23
M18 x 1
LED
M12
89.55
89.55
50
50
23
23
M18 x 1
LED
99.2
50
23
M30 x 1.5
LED
90.45
50
23
M30 x 1.5
LED
M12 x 1
Specifications are subject to change without notice (21.11.03)
3
Teach-in Guide
Adjustment - Background
No target present
Push-button
LED - Green
LED - Yellow
Time (sec)
Press push-button >3 seconds until LEDs are flashing one time per second. The background will be calibrated when the
push-button is released during the following 3 seconds
Adjustment - Object
Target present
Push-button
LED - Green
LED - Yellow
Time (sec)
Press push-button >6 seconds until LEDs are flashing two times per second. The object will be calibrated when the push-
button is released during the following 3 seconds
Adjustment - NO - NC
Push-button
LED - Green
LED - Yellow
Time (sec)
0 1 2 3 4 5 6 7 8 9 10 11 12 13
Press push-button >9 sec. until LEDs are flashing three times per second. The status of NO-NC will toggle when the push-
button is released during the following 3 seconds
BN+
BK
WH
BU-
Wiring Diagrams
I
LOAD
< 250mA
I
ALARM
< 20mA
Teach-in
The PNP- or NPN-load will automatically be
detected.
By means of the Teach-in wire, the functions
described in the Teach-in Guide can be set-
up.
It is possible to Teach-in more sensors at the
same time by connecting the WH-wires in
parallel to the common "-" supply.
(#): Plug connections
Important: If alarm output (WH-wire) is
unused, it has to be terminated to +supply
0 1 2 3 4 5 6 7 8 9 10 11 12 13
0 1 2 3 4 5 6 7 8 9 10 11 12 13
Releasing the push-button after 12 sec. returns the sensor to factory settings.
(1)
(3)
(2)
(4)