ChipFind - документация

Электронный компонент: EI1202TBCFL-3

Скачать:  PDF   ZIP
Specifications are subject to change without notice (07.12.01)
1
Housing
Rated
Ordering no.
Ordering no.
diameter
operating
SCR output
SCR output
dist. (S
n
)
Make switching
Break switching
M12
2 mm
1)
EI 1202 TBOFL-3
EI 1202 TBCFL-3
M12
4 mm
2)
EI 1204 TBOFL-3
EI 1204 TBCFL-3
M18
5 mm
1)
EI 1805 TBOFS-3
EI 1805 TBCFS-3
M18
8 mm
2)
EI 1808 TBOFS-3
EI 1808 TBCFS-3
M30
10 mm
1)
EI 3010 TBOFS-3
EI 3010 TBCFS-3
M30
15 mm
2)
EI 3015 TBOFS-3
EI 3015 TBCFS-3
1)
For flush mounting in metal
2)
For non-flush mounting in metal
Proximity Sensors Inductive
Stainless Steel Housing, Full Metal Body
Types EI, AC, M12, M18, M30, Plug
Stainless steel housing, cylindrical
Diameter: M12, M18, M30
Short versions
Sensing distance: 2 to 15 mm
Rated operational voltage: 20 to 250 VAC
Output: SCR, make or break switching
LED-indication for output ON
Plug versions M12 or 1/2" UNF
Product Description
Proximity switch in stainless
steel housings ranging from
12 to 30 mm. SCR, 500 mA
output. Normally open or
closed output types. Plug ver-
sions M12 or 1/2" UNF.
Type
Housing diameter (mm)
Rated operating dist. (mm)
Output type
Housing material
Connection type
Ordering Key
Type Selection, AC Types
Specifications
Rated operational volt. (U
e
)
24 to 240 VAC, 45 to 65 Hz
(U
B
)
20 to 250 VAC, 45 to 65 Hz
Rated operational current (Ie)
Continuous
500 mA
Short-time
2.5 A, max. 20 ms
Min. operational current (I
m
)
5 mA
Min. rated operational current (I
e
) 10 mA
OFF-state current (Ir)
2 mA at 250 VAC,
typ. 1.2mA
typ. 0.8 mA @ 120 V
Voltage drop (U
d
)
8 VAC, typ. 5 V
Protection
Transient
Transient voltage
2.5 kV/0.5 J/500
Power ON delay (t
v
)
100 ms, typ. 50 ms
Frequency of operating
cycles
(f)
5 Hz
Indication for output ON
LED, yellow
Assured operating dist. (S
a
)
0
S
a
0.81 S
n
Repeat accuracy (R)
5%
Hysteresis (H)
(Differential travel)
3 to 20% of sensing distance
Drift of sensing distance
due to temperature variation
10%
Ambient temperature
Operating
-25 to +70C (-13 to +158F)
Storage
-30 to +80C (-22 to +176F)
Degree of protection
IP 67
(Nema 1, 2, 3, 4, 4x, 12, 13)
Housing material
Body
Stainless steel (1.4301)
Front
Blue polyester, oil proof
Back
Black polyester, oil proof
Approvals
UL (only M18 and M30 types)
CE-marking
Yes
EI 12 02 TBO FL-3
2
Specifications are subject to change without notice (07.12.01)
Size
Shape
Connection
Ordering no.
1/2"
straight
2 m cable
CONH3A-S2 (
)
1/2"
straight
5 m cable
CONH3A-S5 (
)
1/2"
90 angle
2 m cable
CONH3A-A2 (
)
1/2"
90 angle
5 m cable
CONH3A-A5 (
)
EI, AC, M12, M18, M30, Plug
Specifications (cont.)
Type
A
mm
EI 1202 TB.FL-3 (flush)
74.5
EI 1204 TB.FL-3 (non-flush)
78.5
EI 1805 TB.FS-3 (flush)
55.5
EI 1808 TB.FS-3 (non-flush)
63.5
EI 3010 TB.FS-3 (flush)
55.5
EI 3015 TB.FS-3 (non-flush)
67.5
A
EI 120. TB.FL-3
A
EI 180. TB.FS-3
A
EI 301. TB.FS-3
Weight
EI 12.. ....-3
25 g
EI 18.. ....-3
41 g
EI 30.. ....-3
103 g
Tightening torque
EI 12
7.5 Nm (x)
17.5 Nm (y)
EI 18
27.5 Nm
EI 30
100.0 Nm
Wiring Diagrams
Connectors: Type Selection - AC Version (3-wire)
Numbers refer to corresponding plugs.
EI .... TB.F.-3
Connector type: CONH3A-..
Make switching
Break switching
LOAD
LOAD
3
3
2
2
Dimensions
Specifications are subject to change without notice (07.12.01)
3
Installation Hints
Relief of cable strain
Protection of the sensing face
Switch mounted on mobile carrier
To avoid interference from inductive voltage/
current peaks, separate the prox. switch pow-
er cables from any other power cables, e.g.
motor, contactor or solenoid cables
Incorrect
Correct
The cable should not be pulled
A proximity switch should not serve as
mechanical stop
Any repetitive flexing of the
cable should be avoided
EI, AC, M12, M18, M30, Plug