ChipFind - документация

Электронный компонент: EI1805NPCPL

Скачать:  PDF   ZIP
Specifications are subject to change without notice (09.12.01)
1
Proximity Sensors Inductive
Thermoplastic Polyester Housing
Types EI, DC, M12, M18, M30
Euronorm thermoplastic polyester housing,
cylindrical
Diameter: M12, M18, M30.
Sensing distance: 2 to 15 mm
Power supply:
10 to 40 VDC
20 to 250 VAC
Output: Transistor NPN/PNP, make or break switching
SPDT relay, make & break switching
Protection: Short-circuit, reverse polarity and overload
LED-indication for output ON
2 m cable or M12 plug
Product Description
euronorms EN 50 008 and
EN 50 036. For metal versions
refer to type. EI ...S.
Proximity switch in M12, M18
and M30 polyester housings.
Made in accordance with
Type
Housing diameter (mm)
Rated operating dist. (mm)
Output type
Housing material
Body style
Plug
Type Selection DC Types, Cable and M12 Plug
Housing
Body
Connec-
Rated
Ordering no.
Ordering no.
Ordering no.
Ordering no.
diameter style
tion
operating
Transistor NPN
Transistor NPN
Transistor PNP
Transistor PNP
dist. (S
n
)
Make switching
Break switching
Make switching
Break switching
M12
Short
Cable
2 mm
1)
EI 1202 NPOPS
EI 1202 NPCPS
EI 1202 PPOPS
EI 1202 PPCPS
M12
Short
Plug
2 mm
1)
EI 1202 NPOPS-1
EI 1202 NPCPS-1
EI 1202 PPOPS-1 EI 1202 PPCPS-1
M12
Long
Cable
2 mm
1)
EI 1202 NPOPL
EI 1202 NPCPL
EI 1202 PPOPL
EI 1202 PPCPL
M12
Long
Plug
2 mm
1)
EI 1202 NPOPL-1
EI 1202 NPCPL-1
EI 1202 PPOPL-1 EI 1202 PPCPL-1
M12
Short
Cable
4 mm
2)
EI 1204 NPOPS
EI 1204 NPCPS
EI 1204 PPOPS
EI 1204 PPCPS
M12
Short
Plug
4 mm
2)
EI 1204 NPOPS-1
EI 1204 NPCPS-1
EI 1204 PPOPS-1 EI 1204 PPCPS-1
M12
Long
Cable
4 mm
2)
EI 1204 NPOPL
EI 1204 NPCPL
EI 1204 PPOPL
EI 1204 PPCPL
M12
Long
Plug
4 mm
2)
EI 1204 NPOPL-1
EI 1204 NPCPL-1
EI 1204 PPOPL-1 EI 1204 PPCPL-1
M18
Short
Cable
5 mm
1)
EI 1805 NPOPS
EI 1805 NPCPS
EI 1805 PPOPS
EI 1805 PPCPS
M18
Short
Plug
5 mm
1)
EI 1805 NPOPS-1
EI 1805 NPCPS-1
EI 1805 PPOPS-1 EI 1805 PPCPS-1
M18
Long
Cable
5 mm
1)
EI 1805 NPOPL
EI 1805 NPCPL
EI 1805 PPOPL
EI 1805 PPCPL
M18
Long
Plug
5 mm
1)
EI 1805 NPOPL-1
EI 1805 NPCPL-1
EI 1805 PPOPL-1 EI 1805 PPCPL-1
M18
Short
Cable
8 mm
2)
EI 1808 NPOPS
EI 1808 NPCPS
EI 1808 PPOPS
EI 1808 PPCPS
M18
Short
Plug
8 mm
2)
EI 1808 NPOPS-1
EI 1808 NPCPS-1
EI 1808 PPOPS-1 EI 1808 PPCPS-1
M18
Long
Cable
8 mm
2)
EI 1808 NPOPL
EI 1808 NPCPL
EI 1808 PPOPL
EI 1808 PPCPL
M18
Long
Plug
8 mm
2)
EI 1808 NPOPL-1
EI 1808 NPCPL-1
EI 1808 PPOPL-1 EI 1808 PPCPL-1
M30
Short
Cable
10 mm
1)
EI 3010 NPOPS
EI 3010 NPCPS
EI 3010 PPOPS
EI 3010 PPCPS
M30
Short
Plug
10 mm
1)
EI 3010 NPOPS-1
EI 3010 NPCPS-1
EI 3010 PPOPS-1 EI 3010 PPCPS-1
M30
Long
Cable
10 mm
1)
EI 3010 NPOPL
EI 3010 NPCPL
EI 3010 PPOPL
EI 3010 PPCPL
M30
Long
Plug
10 mm
1)
EI 3010 NPOPL-1
EI 3010 NPCPL-1
EI 3010 PPOPL-1 EI 3010 PPCPL-1
M30
Short
Cable
15 mm
2)
EI 3015 NPOPS
EI 3015 NPCPS
EI 3015 PPOPS
EI 3015 PPCPS
M30
Short
Plug
15 mm
2)
EI 3015 NPOPS-1
EI 3015 NPCPS-1
EI 3015 PPOPS-1 EI 3015 PPCPS-1
M30
Long
Cable
15 mm
2)
EI 3015 NPOPL
EI 3015 NPCPL
EI 3015 PPOPL
EI 3015 PPCPL
M30
Long
Plug
15 mm
2)
EI 3015 NPOPL-1
EI 3015 NPCPL-1
EI 3015 PPOPL-1 EI 3015 PPCPL-1
1)
For flush mounting in metal
Make switching = Normally Open (NO)
2)
For non-flush mounting in metal
Break switching = Normally Closed (NC)
Ordering Key
EI 1202 NPOPS-1
2
Specifications are subject to change without notice (09.12.01)
EI, DC, M12, M18, M30, Cable
Type Selection Relay Output
Housing
Rated
Ordering no.
Ordering no.
Ordering no.
Ordering no.
diameter
operating
Make & break swit.
Make & break swit.
Make & break swit.
Make & break swit.
dist. (S
n
)
12 VAC/DC
24 VAC/DC
115 VAC
230 VAC
30 mm
10 mm
1)
EI 3010 RNAP 912
EI 3010 RNAP 924
EI 3010 RNAP 115
EI 3010 RNAP 230
30 mm
15 mm
2)
EI 3015 RNAP 912
EI 3015 RNAP 924
EI 3015 RNAP 115
EI 3015 RNAP 230
1)
For flush mounting in metal
Make switching = Normally Open (NO)
2)
For non-flush mounting in metal
Break switching = Normally Closed (NC)
Specifications
Transistor NPN/PNP
SPDT relay
Rated operational volt. (U
e
)
12 to 36 VDC
912: 10.8 to 13.2 VAC/DC, 50 to 60 Hz
(U
B
)
10 to 40 VDC (ripple incl.)
924: 21.6 to 26.2 VAC/DC, 50 to 60 Hz
115: 97 to 135 VAC, 50 to 60 Hz
230: 207 to 250 VAC, 50 to 60 Hz
Ripple
10%
-
Rated operational current (I
e
)
Continuous
200 mA
2 A
Short-time
10 A, max. 25 ms
Max. power
-
AC: 760 VA DC: 150 W
No-load supply current (I
o
)
Output ON: < 6.5 mA
12 VAC/DC: 65/35 mA
Output OFF: < 2.7 mA
24 VAC/DC: 34/13 mA
115 VAC: 16 mA
230 VAC: 16 mA
Voltage drop (U
d
)
2 VDC at max. load
-
Protection
Reverse polarity, short-circuit, transients
None
Transient voltage
700 V/0.5 J
1 kV/0.5 J (prepared)
EMC
Approved acc. to EN 50 080, EN 50 081
-
Power ON delay
< 10 ms
60 ms
Frequency of operating cycles (f)
EI 1202 800 Hz EI 1808 400 Hz
10 Hz
EI 1204 500 Hz EI 3010 300 Hz
EI 1805 500 Hz EI 3015 100 Hz
Indication for output ON
LED, yellow
LED, yellow
Assured operating dist. (S
a
)
0
S
a
0.81 S
n
0
S
a
0.81 S
n
Repeat accuracy (R)
5%
5%
Hysteresis (H) (Differential travel)
1 to 15% of sensing distance
3 to 20% of sensing distance
Effective operating dist. (S
r
)
0.9 x S
n
S
r
1.1 x S
n
0.9 x S
n
S
r
1.1 x S
n
Usable operating dist. (S)
0.9 x S
r
S
u
1.1 x S
r
0.9 x S
r
S
u
1.1 x S
r
Ambient temperature
Operating
-25 to +70C (-13 to +158F)
-25 to +70C (-13 to +158F)
Storage
-30 to +80C (-22 to +176F)
-30 to +80C (-22 to +176F)
Degree of protection
IP 67 (Nema 1, 3, 4, 6, 13)
IP 67 (Nema 1, 3, 4, 6, 13)
Housing material
Body
Grey thermoplastic polyester
Blue thermoplastic polyester
Back
Black polyester
Blue thermoplastic polyester
Connection
Cable
2 m, 3 x 0.3 mm
2
, grey PVC, oil proof
2 m, 5 x 0.50 mm
2
, grey PVC, oil proof
Plug
M 12 x 1
Cables for plug (-1)
CONH1A serie
Weight (cable excluded)
EI 12
10 g EI 3010
50 g
180 g
EI 1805
18 g EI 3015
70 g
EI 1808
20 g
Tightening torque
EI 12
1.8 Nm EI 30
7.5 Nm
7.5 Nm
EI 18
2.6 Nm
Approvals
UL, CSA
UL, CSA
CE-marking
Yes
Yes
Specifications are subject to change without notice (09.12.01)
3
EI, DC, M12, M18, M30
Dimensions
Type
A
B
C
D
E
F
G
H
I
SW
K
L
mm mm
mm
mm
mm mm mm mm mm mm mm
EI 1202 XPXPS
M 12 x 1 x 30
10.7
30
11
5.0
8
17
EI 1202 XPXPL
M 12 x 1 x 50
10.7
50
11
5.0
8
17
EI 1202 XPXPS-1
M 12 x 1 x 30
10.7
30
12.6
11.9
8
17
EI 1202 XPXPL-1
M 12 x 1 x 50
10.7
50
12.6
11.9
8
17
EI 1204 XPXPS
M 12 x 1 x 30
10.7
34
11
5.0
8
17
EI 1204 XPXPL
M 12 x 1 x 50
10.7
54
11
5.0
8
17
EI 1204 XPXPS-1
M 12 x 1 x 30
10.7
34
12.6
11.9
8
17
EI 1204 XPXPL-1
M 12 x 1 x 50
10.7
54
12.6
11.9
8
17
EI 1805 XPXPS
M 18 x 1 x 30
16.7
30
11.6
15.4
8
24
EI 1805 XPXPL
M 18 x 1 x 50
16.7
50
11.6
15.4
8
24
EI 1805 XPXPS-1
M 18 x 1 x 30
16.7
30
13.1
11.9
8
24
EI 1805 XPXPL-1
M 18 x 1 x 50
16.7
50
13.1
11.9
8
24
EI 1808 XPXPS
M 18 x 1 x 30
16.7
38
11.6
15.4
8
24
EI 1808 XPXPL
M 18 x 1 x 50
16.7
58
11.6
15.4
8
24
EI 1808 XPXPS-1
M 18 x 1 x 30
16.7
38
13.1
11.9
8
24
EI 1808 XPXPL-1
M 18 x 1 x 50
16.7
58
13.1
11.9
8
24
EI 3010 XPXPS
M 30 x 1.5 x 30
28
30
13.6
15.4
10
36
EI 3010 XPXPL
M 30 x 1.5 x 50
28
50
13.6
15.4
10
36
EI 3010 XPXPS-1
M 30 x 1.5 x 30
28
30
13.6
11.9
10
36
EI 3010 XPXPL-1
M 30 x 1.5 x 50
28
50
13.6
11.9
10
36
EI 3015 XPXPS
M 30 x 1.5 x 30
28
42
13.6
15.4
10
36
EI 3015 XPXPL
M 30 x 1.5 x 50
28
62
13.6
15.4
10
36
EI 3015 XPXPS-1
M 30 x 1.5 x 30
28
42
13.6
11.9
10
36
EI 3015 XPXPL-1
M 30 x 1.5 x 50
28
62
13.6
11.9
10
36
RNAP
EI 3010
M 30 x 1.5
28.16
80
19.5
2000
1
59
20
10
36
15
6.7
EI 3015
M 30 x 1.5
28.16
80
19.5
2000
12
48
20
10
36
15
6.7
Cable
EI 30 .. RNAP
A
I
SW
C
D
E
LED
B
F
SW
A
Plug
C
D
E
LED
B
F
SW
A
M 12 x 1
4
Specifications are subject to change without notice (09.12.01)
Installation Hints
Relief of cable strain
Protection of the sensing face
Switch mounted on mobile carrier
To avoid interference from inductive voltage/
current peaks, separate the prox. switch pow-
er cables from any other power cables, e.g.
motor, contactor or solenoid cables
Incorrect
Correct
The cable should not be pulled
A proximity switch should not serve as
mechanical stop
Any repetitive flexing of the
cable should be avoided
Wiring Diagrams
+
-
1 BN
4 BK
3 BU
+
-
1 BN
2 WH
3 BU
+
-
1 BN
4 BK
3 BU
+
-
1 BN
2 WH
3 BU
NPN - Make switching
NPN - Break switching
PNP - Make switching
PNP - Break switching
Power Supplies
Power supplies VAC:
> SS 110.
Power supplies VDC:
> SS 130/140.
Power supplies with amplifier relays: > SV 190.
EI, DC, M12, M18, M30