ChipFind - документация

Электронный компонент: EI5515TBOP-6

Скачать:  PDF   ZIP
Specifications are subject to change without notice (25.06.99)
1
Sensing distance 10 or 15 mm
Rated operational voltage: 20 to 250 VAC
Output: SCR, make or break switching
LED indication for output ON
Protection: Transients
Inductive, Capacitive and Photoelectric flat pack
series in PC housing, IP 67
Cable and plug versions
Proximity Sensors Inductive
Flat pack Polycarbonate Housing
Types EI 5510/EI 5515, AC-Types
AC inductive proximity switch-
es with sensing distance 10
mm mounted in metal or 15
mm non-flush mounted. Flat
pack housing size (W x H x D)
35 x 55 x 15 mm made in
polycarbonate. Easy mounting
with only two M 3.5 screws.
Ideal for use in conveying and
material handling applications.
Type: Inductive proximity
switch
Housing
Range
Output type
Housing material
Connection type
Product Description
Ordering Key
Type Selection, AC Types
Housing
Rated
Ordering no.
Ordering no.
Ordering no.
Ordering no.
diameter
operating
Cable
Cable
Plug
Plug
W x H x D
dist. (S
n
)
Make switching
Break switching
Make switching
Break switching
35 x 55 x 15
10 mm
EI 5510 TBOP
EI 5510 TBCP
EI 5510 TBOP-6
EI 5510 TBCP-6
15 mm
EI 5515 TBOP
EI 5515 TBCP
EI 5515 TBOP-6
EI 5515 TBCP-6
Specifications
Rated operational volt. (U
e
)
24 to 240 VAC
(U
B
)
20 to 250 VAC, 50 to 60 Hz
Rated operational current (I
e
)
Continuous
10 to 500 mA
Short-time
2.5 A, max. 20 ms
Minimum load current (I
o
)
5 mA
OFF-state current (I
r
)
20mA
Voltage drop (U
d
)
8 VAC at max. load
Protection
Transients
Transient voltage
Level 3, 2.5 kV, acc. to IEC-
60255-5 (500
, 0.5 J)
Power ON delay
100 ms
Frequency of operating
cycles
(f)
5 Hz
Indication for output ON
LED, yellow
Assured operating dist. (S
a
)
0
S
a
0.81 S
n
Repeat accuracy (R)
5%
Hysteresis (H)
(Differential travel)
3 to 20% of sensing distance
Effective operating dist. (S
r
)
0.9 x S
n
S
r
1.1 x S
n
Usable operating dist. (S
u
)
0.9 x S
r
S
u
1.1 x S
r
Ambient temperature
Operating
-25 to +70C (-13 to +158F)
Storage
-30 to +80C (-22 to +176F)
EI 55 10 TBO P-6
Degree of protection
IP 67 (Nema 1, 3, 4 ,6, 13)
Housing material
Polycarbonate, grey
Connection
Cable
2 m, 4 x 0.3 mm
2
grey PUR, oil proof
Plug
M 12 x 1 (double keyed)
Cables for plug (-6)
CONH6A-xx
Weight
125 g cable version
40 g plug version
EMC ratings
Acc. to EN 50 082-2
EN 61 000-4-2 ESD
Contact discharge
4 kV
Air discharge
8 kV
EN 61 000-4-4 Fast transient
Rep. freq. 5 kHz
2 kV
ENV 50 140 RF Electromagnetic
AM, 80-1000 mHz
10 V/m
ENV 50 141 Conducted
Disturbance
10 V/m
ENV 50 204 RF Electromagnetic
field PM, 80-900 MHz
10 V/m
Approvals
UL, CSA
CE-marking
Yes
2
Specifications are subject to change without notice (25.06.99)
Dimensions
EI 5510/EI 5515, AC-Types
EI 551. TB.P
EI 551. TB.P-6
LED
LED
Wiring Diagrams
TBOP
TBCP
3 BU
2 BN
2 BN
3 BU
Accessories
Plugs CONH6A.. serie, please refer to "Accessories".
Delivery Contents
Inductive switch: EI 551. ....
Packaging: Corrugated cardboard
(environmentally friendly recycling material).