ChipFind - документация

Электронный компонент: ET5505NPAP-1

Скачать:  PDF   ZIP
Specifications are subject to change without notice (24.03.2006)
1
Product Description
Photoelectrics
Through-beam
Type ET 5505
Range: 5 m
Modulated infrared light
Rated operational voltage: 10 to 30 VDC
Output: DC 200 mA, NPN or PNP
Make and break switching functions
LED-indication for power supply ON (emitter) and
target detected (receiver)
Photoelectric, inductive and capacitive flat pack series
in PC housing, IP 67
Cable and/or plug versions
High power through-beam
photoelectric switch. Range
up to 5 m. LED indication for
target detected (emitter). Pre-
cise detection through narrow
beam. Flat pack housing size
35 x 55 x 15 mm (W x H x D)
made in polycarbonate. Easy
mounting with only two M3.5
screws. Ideal for use in con-
veying and material handling
applications.
Type
Housing diameter
Range
Output type
Housing material
Connection type
Ordering Key
Type Selection
Specifications Emitter
Rated operational volt. (U
B
)
10 to 30 VDC
(ripple included)
Ripple
10%
Supply current (I
o
)
30 mA
Protection
Reverse polarity,
short-circuits, transients
Light source
GaAIAs LED, 880 nm
Light type
Infrared, modulated
Optical angle
8
Indication
Supply ON
LED, green
Specifications Receiver
Rated operational volt. (U
B
)
10 to 30 VDC
(ripple included)
Ripple
10%
No-load supply current (I
o
)
15 mA
OFF-state current (I
r
)
100 A (typ. 0)
Output current (I
e
)
Continuous
200 mA
Voltage drop (U
d
)
2.5 VDC
Protection
Reverse polarity,
short-circuit, transients
Hysteresis (H)
< 20%
Temperature drift
0.4%/C
Optical angle
7.5
Ambient light
Max. 5,000 lux
Operating frequency (f)
Typ. 100 Hz
Response time
OFF-ON (t
ON
)
4 ms
ON-OFF (t
OFF
)
6 ms
Power ON delay (t
v
)
300 ms
Indication
Output ON
LED, yellow
Housing
Rated
Connection
Ordering no.
Ordering no.
Ordering no.
diameter
operating
Receiver/NPN Receiver/PNP
Emitter
(W x H x D)
dist. (S
n
)
Make & break switching
Make & break switching
35 x 55 x 15
5 m
Cable
ET 5505 NPAP
ET 5505 PPAP
ET 5505
5 m
Plug
ET 5505 NPAP-1
ET 5505 PPAP-1
ET 5505-1
Note: Please order emitter and receiver separately.
ET 55 05 NPA P-1
2
Specifications are subject to change without notice (24.03.2006)
Dimensions
ET 5505
Environment
Overvoltage category
III (IEC 60664/60664A;
60947-1)
Pollution degree
3 (IEC 60664/60664A;
60947-1)
Degree of protection
IP 67 (IEC 60529; 60947-1)
Note: Plug version,
IP 67 with mounted plug,
CON.1A..
Temperature
Operating
-20 to +60C (-4 to +140F)
Storage
-30 to +70C (-22 to +158F)
Vibration
10 to 150 Hz, 0.5 mm/7.5 g
(IEC 60068-2-6)
Shock
2 x 1 m & 100 x 0.5 m
(IEC 60068-2-32)
Dielectric voltage
500 VAC (rms)
Housing material
Polycarbonate, black
Connection cable
Cable
Grey, 2 m oilproof, PVC,
4 x 0.34 m, 5.2 mm
Note:
Other lengths on request
Plug (-1)
M 12
Cables for plug (-1)
CON.1A-.. series
Weight
Cable version
125 g
Plug version
40 g
Approval
UL
CE-marking
Yes
General Specifications
Truth Table
Make switching
Break switching
Object present
Yes
No
Yes
No
LED
Off
On
Off
On
Load
Non-active
Active
Active
Non-active
Output NPN
High
Low
Low
High
Output PNP
Low
High
High
Low
DC types
Accessories
Connector type CON.1A../CON.14NF.. series.
Please refer to "Accessories".
Delivery Contents
Photoelectric switch: ET 5505 ....
Packaging: Plastic bag
ET 550. .PAP
ET 550. .PAP-1
LED
15
35
M12x1 plug
25
7
3.5
55
57.5
68.3
4
4.5
LED
15
57.5
35
55
7.5
18
6.8
5.2
3.5
25
7
4.5
4
Specifications are subject to change without notice (24.03.2006)
3
Operation Diagram
ET 5505
Power supply
Object present, light beam interrupted
Tv
Tv
Output ON: Break switching (NC)
Make switching (NO)
Wiring Diagrams
1 BN
2 WH
4 BK
3 BU
3 BU
2 WH
4 BK
1 BN
PNP
NPN
Emitter
Installation Hints
Relief of cable strain
Protection of the sensing face
Switch mounted on mobile carrier
To avoid interference from inductive voltage/
current peaks, separate the prox. switch pow-
er cables from any other power cables, e.g.
motor, contactor or solenoid cables
Incorrect
Correct
The cable should not be pulled
A proximity switch should not serve as
mechanical stop
Any repetitive flexing of the
cable should be avoided