ChipFind - документация

Электронный компонент: G21960000700

Скачать:  PDF   ZIP
Du line
Fieldbus
Installationbus
Specifications are subject to change without notice (29.04.03)
1
Dupline
is a registered trademark. A product of the CARLO GAVAZZI Group
Type: Dupline
Open PCB
Combined module
Interface type
DC supply
Dupline
Channel Generator
128 signals and DC power supply on 3 wires
RS 485 port for interfacing to control system
Automatic communication with specific PLC's/Controllers
Multidropping of up to 16 G 2196 0000 or
G 2196 0005 on RS 485
Cost-effective design on open PCB (86 x 54 mm)
LED-indications for supply, Dupline
carrier and
RS 485 Tx
DC-supply
Product Description
Ordering Key
G 2196 00.. is a combined
module on open printed circuit
board. The unit performs three
functions: Dupline
channel ge-
nerator, power supply synchro-
nization (enables 3-wire system
with supply) and RS 485 inter-
face. It has been designed as
a cost-effective solution for
multiplexing the push-button
and lamp signals in elevators.
The standard version of the
Master Module has a general-
purpose RS 485-protocol
available, but to facilitate the
interfacing easy, special pro-
tocol versions of the master
module for automatic commu-
nication with specific PLC's/
Controllers are developed con-
tinouosly. These are listed
under "Type Selection".
Type Selection
Supply
PLC Interface type
Ordering no.
PLC Interface type
Ordering no.
20-30 VDC
Standard protocol
G 2196 0000 700
Mitsubishi FX- and A-series
G 2196 0003 700
20-30 VDC
Lucky Goldstar K-series
G 2196 0001 700
Omron
G 2196 0004 700
20-30 VDC
GE-Fanuc 90-30 series
G 2196 0002 700
Modbus RTU Slave
G 2196 0005 700
G 2196 0000 700
Input/Output Specifications
Supply Specifications
Dupline
Master Module
Power output
Output voltage
20-30 VDC (pulsating)
Output current
< 4.0 A @ 25C
Short circuit protection
4 A quick acting fuse
Output voltage drop
< 1.0 V
Dupline
carrier
Output voltage
8.2 V (pulsating)
Current
< 40 mA
Short circuit protection
Yes
Scan time
128 channels
132.2 ms
64 channels
69.8 ms
RS 485 communication port
Communication speed
19200 Baud
Connection
9 pole female SUB-D
Pin assignment
Data line + (B)
Pin 3
Data line - (A)
Pin 8
5 VDC supply +
Pin 6
5 VDC GND
Pin 5
Current load 5 VDC supply
< 150 mA
Dielectric voltage
RS 485 port - Dupline
> 2 kVAC (rms)
Settings
Device no. (for RS 485)
(only G 2196 0000)
4 DIP-switches
64 or 128 channels
1 DIP-switch
Power supply
Overvoltage cat. III (IEC 60664)
Operational voltage (V
in
)
20-30 VDC
Reverse polarity protection
None
Current consumption
< 100 mA
Power dissipation
< 6 W
Inrush current
< 200 mA
Transient protection voltage
800 V
Dieelectric voltage
Supply - Dupline
None
Supply - RS 485 port
> 2 kVAC (rms)
Type G 2196 00..
Du line
Fieldbus
Installationbus
2
Specifications are subject to change without notice (28.09.99)
Dupline
is a registered trademark. A product of the CARLO GAVAZZI Group
Mode of Operation
The G 219600.. Dupline
mas-
ter module (DMM) is part of the
Dupline
concept for multi-
plexing the push-button and
lamp signals in elevators. As
shown on the wiring diagram a
3-wire bus with signal, DC-
power and common GND
goes throughout the shaft to all
the push-button panels and
floor indicators, and to the car.
The DMM is connected to a
standard DC-supply which it
synchronizes with the Dupline
carrier signal before it is output
to supply the push-button
panels. The synchronization is
necessary in order to enable
the Dupline
and DC-supply to
share the GND-wire.
The most cost-effective way to
interface the elevator controller
to the master module is to
make use of the RS 485 port
(see wiring diagram). In this
way, the size and the number
of controller I/O-board(s) can
be reduced significantly, since
the I/O-terminals for lamps,
pushbuttons and floor-indica-
tors are no longer needed.
Based on requests from cus-
tomers, special versions of the
master module for automatic
communication with specific
PLC's/Controllers are devel-
oped continuously. This makes
the interfacing very easy, since
these devices automatically
transfer the Dupline
data to/
from the internal memory of
the PLC/ Controller. The ver-
sions available for the moment
are listed under "Type Selec-
tion". More detailed information
about interfacing to the indi-
vidual PLC-types are available.
The standard version G 2196
0000 700 utilizes a general pur-
pose protocol for implementa-
tion in any PLC/Controller soft-
ware. In this case, the commu-
nication is not automatic, since
it must be driven from the
application software.
Another way to implement the
elevator controller interface is
to make hardwired connec-
tions between the I/O's of the
controller and Dupline
-mo-
dules positioned next to it, thus
making use of the peer-to-peer
communication capability of
Dupline
. This solution is less
cost-effective, but highly flexi-
ble since existing and different
control-systems can be used.
G 2196 00..
Wiring Diagram
Car
panel
GND
Signal
Power
G 2196 00..
1 2 3 4 5
DIP-switch Setting for G21960000700
ON
2
3
2
1
2
3
4
5
The device no. and number
of Dupline
channels are
selected by means of 5
DIP-switches.
SW
ON
OFF
1-4
Device no.
5
64 ch.
128 ch.
Accessories
Data brochure DAT DMM
(RS 485 protocol specification and design hints)
+ -
=
~
Terminal
Function
1
GND
2
Dupline
Signal
3
Power Out
4
GND
5
DC Power Supply
Lift
Controller
RS 485
General Specifications
Power ON delay
2 s
Indication for
RS 485 Tx
LED, red
Supply ON
LED, green
Dupline
carrier
LED, yellow
Environment
Pollution degree
2 (IEC 60664)
Operating temperature
0 to +50C (+32 to +122F)
Storage temperature
-50 to +85C (-58 to +185F)
Humidity (non-condensing)
20 to 80%
Mechanical resistance
Shock
15 G (11 ms)
Vibration
2 G (6 to 55 Hz)
Dimensions
86 x 54 mm open printed
circuit board, 4.2 mm hole in
each corner for mounting
Weight
100 g
1. floor
2. floor
3. floor
n floor