ChipFind - документация

Электронный компонент: G34960002700

Скачать:  PDF   ZIP
Du line
Fieldbus
Installationbus
Specifications are subject to change without notice (05.05.03)
1
Dupline
is a registered trademark. A product of the CARLO GAVAZZI Group
Type: Dupline
H4-Housing
Combined module
Interface type
DC supply
GE-Fanuc master
Plug and play: Automatic communication with specific
PLC/Controllers
Built-in normal Dupline
Channel Generator
128 I/O's and DC power supply on 3 wires
RS232/RS422/RS485 port for interfacing to control
system
Split-I/O mode selectable (128 inputs and 128 outputs)
LED-indications for supply, Dupline carrier and Com-
port TX
Galvanically isolated Com-port supplied by internal
DC/DC converter
Product Description
Ordering Key
G 3496 0002 is designed as a
cost-effective solution for
interfacing Dupline
I/O's to a
GE-Fanuc PLC. It performs
three functions: Dupline
channel generator, power
supply synchronization (en-
ables 3-wire system with sup-
ply) and RS232/RS422/
RS485 interface.
Type Selection
Supply
PLC Interface Conformance
Ordering no.
20-30 VDC
GE-Fanuc Micro 90 & 90-30
G 3496 0002 700
G 3496 0002 700
Input/Output Specifications
Dupline
Plug & Play Master Module
Interface for GE-Fanuc PLC
Power output
Output voltage
20-30 VDC (pulsating)
Output current
< 3.0 A @ 50C
Short circuit protection
4 A quick acting fuse
Output voltage drop
< 1.0 V
Dupline
carrier
Output voltage
8.2 V (pulsating)
Current
< 60 mA
Short circuit protection
Yes
Scan time
128 channels
132.2 ms
64 channels
69.8 ms
Communication port
Standard
RS232/RS422/RS485
Split I/O mode
Yes, selectable
Normal Dupline mode
Yes, selectable
Connection
9 pole female Sub-D
Dielectric voltage
Com-port Dupline
1 kVAC (rms)
Protocol
SNP / Modbus-RTU
(Function code 01 & 15)
Baud rate
19200 (9600 for Modbus-
RTU protocol)
Data bits
8
Start bit
1
Stop bit
1
Parity
Odd
Flow-control
None
Type G 3496 0002
Input/Output Specifications (Cont.)
Pin assignment
2-wire RS 485
S/R Data line + (B)
Pin 3
S/R Data line - (A)
Pin 8
GND
Pin 5
4-wire RS 485/RS 422
R Data line + (B)
Pin 3
R Data line - (A)
Pin 8
S Data line + (B)
Pin 2
S Data line - (A)
Pin 7
Direction
Pin 4
(Connect to GND pin 5
when using 4-wire commu-
nication)
RS 232
TX
Pin 1
RX
Pin 9
GND
Pin 5
Supply Specifications
Power supply
Overvoltage cat. III (IEC 60664)
Operational voltage (V
in
)
20-30 VDC
Reverse polarity protection
None
Current consumption
< 150 mA + Power load
Power dissipation
< 5 W
Transient protection voltage
800 V
Dielectric voltage
Supply - Dupline
None
Supply - com-port
1 kVAC (rms)
Power ON delay
2 s
Indication for
Com-port Tx
LED, red
Supply ON
LED, green
Dupline
carrier
LED, yellow
Environment
Pollution degree
3 (IEC 60664)
Operating temperature
0 to +50C (+32 to +122F)
Storage temperature
-50 to +85C (-58 to +185F)
Du line
Fieldbus
Installationbus
2
Specifications are subject to change without notice (30.08.00)
Dupline
is a registered trademark. A product of the CARLO GAVAZZI Group
Mode of Operation
The Dupline
Master Module
(DMM) controls a 3-wire bus
with signal, DC-power and
common GND. The DMM is
connected to a standard DC-
supply, which it synchronizes
with the Dupline
carrier signal
before it is output to supply.
The synchronization is neces-
sary in order to enable the
Dupline
and DC-supply to
share the GND-wire.
The Dupline
Master Module is
a Dupline
Channel Generator
with the function of a master.
This means that the 128
Dupline
I/O's will be read/writ-
ten by the DMM and then sent
to the PLC.
The DMM can run in two dif-
ferent modes Normal mode
and split I/O mode. In Normal
mode, Dupline
operates as a
peer-to-peer system, where
the channel generator auto-
matically establishes a con-
nection between Dupline
inputs and Dupline
outputs
which are coded to the same
Dupline
address. If e.g. an
input coded for B5 is activat-
ed, the output(s) coded for B5
will also be activated.
Consequently, a Dupline
-out-
put can either be activated
through the output-data
received on DMM or by an
active Dupline
input coded
for the same Dupline
-
address. In "Split I/O" mode,
the channel generator treats
the Dupline
inputs and
Dupline
outputs indepen-
dently. If e.g. an input coded
for B5 is activated, the DMM
will make the information avail-
able for the PLC (like in normal
mode), but it will not automati-
cally activate the Dupline
out-
put(s) coded to B5. The
Dupline
outputs are con-
trolled exclusively through the
output data received from the
PLC. In this mode, up to 128
Dupline
inputs and 128
Dupline
outputs are available,
since an input and an output
coded to the same Dupline
address can operate indepen-
dently.
G 3496 0002
General Specifications
Humidity (non-condensing)
20 to 80%
Mechanical resistance
Shock
15 G (11 ms)
Vibration
2 G (6 to 55 Hz)
Dimensions
H4-Housing
Material
(see Technical information)
Weight
100 g
Dip-Switch Setting
Memory Mapping
Dupline
GE-Fanuc
Dupline
GE-Fanuc
Channel
Channel
Read
Write
Read
Write
A1
Q0257
Q0385
E1
Q0289
Q0417
A2
Q0258
Q0386
F1
Q0297
Q0425
A3
Q0259
Q0387
G1
Q0305
Q0433
A4
Q0260
Q0388
H1
Q0313
Q0441
A5
Q0261
Q0389
I1
Q0321
Q0449
A6
Q0262
Q0390
J1
Q0329
Q0457
A7
Q0263
Q0391
K1
Q0337
Q0465
A8
Q0264
Q0392
L1
Q0345
Q0473
B1
Q0265
Q0393
M1
Q0353
Q0481
B8
Q0272
Q0400
N1
Q0361
Q0489
C1
Q0273
Q0401
O1
Q0369
Q0497
D1
Q0281
Q0409
P1
Q0377
Q0505
Table of the memory mapping to the PLC
Sw.2
On:
High PLC-memory Add, i.e. all address
numbers are increased by 256. This
selling is only used when two DMM are
connected to the same PLC.
Off:
Sw.3
On:
Modbus-RTU Mode
Off:
SNP Mode
Sw.4
On:
Split I/O Channel Generator Mode
(See "Mode of Operation")
Off:
Normal Dupline
Monostable Channel
Generator Mode
Sw.5 On:
64 Dupline
channels
Off:
128 Dupline
channels
Wiring Diagram
1
2
3
4
21
22
27
28
Supply in
20-30 V DC
24
23
6
7
8
5
26
25
+
-
Power out
GND
Dupline Signal
RS 232
RS 485
3W
Du line
Fieldbus
Installationbus
Specifications are subject to change without notice (30.08.00)
3
Dupline
is a registered trademark. A product of the CARLO GAVAZZI Group
Installation Hints
Interfacing to GE-Fanuc 90-30 PLC's directly on the program-
mingport (Switch 3 OFF & switch 2 OFF)
Interfacing to GE-Fanuc 90-30 PLC's CPU type 331 or higher,
equipped with communication coprocessor module CMM 311 in
Modbus-RTU mode (Switch 3 ON & switch 2 OFF)
Interfacing to GE-Fanuc 90-30 PLC's CPU type 350 or higher,
equipped with communication coprocessor module CMM 311 in
Modbus-RTU mode (Switch 3 ON & switch 2 ON)
No TX-LED
Configuration fault
Check Dip-Switches check
configuration in PLC
Hardware fault
Check the wiring.
No Dupline
Carrier-LED
Short circuit
Short circuit between the
two Dupline
wires.
Accessories
GE-Fanuc 90-30 / 90 Micro
Cable Sub-D 9M/15M for 15p
Programming port
RS-422-GE1
GE-Fanuc CMM311
Cable Sub-D 9M/25M for 25p
Communication port
RS-422-GE2
Additional Information
Scope of supply
1 x Master Module
G3496 0002 700
Pin Assignment
1
9
8
7
6
5
4
3
2
7
2
8
3
5
4
6
1
9
8
15
3K3
3K3
1
9
8
7
6
5
4
3
2
7
2
8
3
5
4
6
1
14
13
25
External
5 V DC-supply or
pin 5(+) and 7 (-) on
15-pin Programming port
-
+
Only for G 2196 0002
RS-422-GE2
RS-422-GE1
G 3496 0002