ChipFind - документация

Электронный компонент: G54606606115

Скачать:  PDF   ZIP
Du line
Fieldbus
Installationbus
Specifications are subject to change without notice (23.01.03)
1
Dupline
is a registered trademark. A product of the CARLO GAVAZZI Group
16 channel status LED indicator
Label slide for LED descriptions
Individual address coding of LED's
Normal or inverted LED operation per 8 channel group
AC/DC power supply
NPN transistor output for loss of Dupline carrier
Horizontal panel mounting, 96 x 96 mm
Product Description
Ordering Key
Type: Dupline
Type no.
Supply
Type Selection
Supply
Ordering no.
16 channels, 16-dot LED
24 VAC
G5460 6606 024
115 VAC
G5460 6606 115
230 VAC
G5460 6606 230
12 VDC
*
* All AC-types may be supplied with 12 VDC through pins 2 & 3.
AC supply through pins 21 & 22.
G 5460 6606 230
Display/Output Specifications
Supply Specifications
Display for Digital Signals
Power supply
Overvoltage cat. III (IEC 60664)
Operational voltage,
through pins 21/22 230
230 VAC 15% (IEC 60038)
115
115 VAC 15% (IEC 60038)
024
24 VAC 15% (IEC 60038)
Frequency
45 to 65 Hz
Voltage interruption
40 ms
Rated operational power
Typ. 4 VA
Rated impulse withstand
voltage
230 V
4 kV
115 V
2,5 kV
024 V
800 V
Dielectric voltage
Supply Dupline
4 kVAC (rms)
Supply Output
4 kVAC (rms)
Alternative DC supply
Overvoltage cat. III (IEC 60664)
Operational voltage (V
DDin
),
through pins 2/3
12 VDC 10% (ripple incl.)
Reverse polarity protection
Yes
Rated operational current
65 mA
Inrush current
1 A
Type G5460 6606
Dupline display for panel
mounting. Status indication
of 16 channels in 16 segment
single point LED representa-
tion.
Display function normal or
inverted for fast locating of
deviations from normal oper-
ation, e.g. missing start-up
conditions, open doors and
windows, machine fault
announciation etc.
Replaces all old channel dis-
play types (FK3C and FK4C).
Display
Display format
Channel status
Display type
LED
Size of LEDs
5
Display colour
Red
Display test
None, but display test can
be performed by setting
internal switches to normal,
programming fail polarity to
"I" with GAP 1605, and
then unplug the Dupline
connection.
Fault output (pin 4)
Voltage range V
BB
4 to 35 VDC (or V
DDin
)
Reverse-polarity protection
Yes
Current
100 mA
Short-circuit protection
None
Built-in protective diodes
None
Off-state leakage current
100 A
Voltage drop
1.5 V
Cable length
3 m
Dielectric voltage
Output Dupline
None
Display/Output Specifications (cont.)
DC in, output & Dupline
connections
4 pole, 5 mm, plugable
Response time
< 2 pulse trains
Du line
Fieldbus
Installationbus
2
Specifications are subject to change without notice (23.01.03)
Dupline
is a registered trademark. A product of the CARLO GAVAZZI Group
Mode of Operation
Wiring Diagram
1 2 3 4 21 22
- V
BB
+
D+
D-
V
DD
IN
G 5460 6606
16 channel status indicator
with LED display.
The display is used to moni-
tor 2 Dupline channel groups
or 16 individual channels.
The output LEDs turn on
when the respective chan-
nels of the selected channel
groups are activated by
transmitters. Each LED re-
presents the status of one
channel. The left highest figure
on the front plate indicates
the lowest output of the first
channel group and the right
lowest figure indicates the
highest output of the last
channel group selected.
In case of Dupline carrier loss
the line LED turn off, and the
fault output turns on.
Notes
If DC-supplied displays are
used, the length of the sup-
ply bus must not exceed 3 m
in order to avoid distur-
bances from unbalancing of
the Dupline.
To change the display oper-
ation from Normal to
Inverted, remove the front
plate and select the required
operation at the selector
switch.
By downloading label tem-
plate from the Dupline home
page (www.dupline.com) it is
possible to generate labels
for the slides.
NB! In printer options, un-
check: Allow A4/letter paper
resizing.
Supply Specifications (cont.)
Rated impulse withstand
voltage
800 V
Dielectric voltage
Supply Dupline
None
Supply Output
None
Supply connection
2 pole, 10 mm, plugable
General Specifications
Output OFF delay
Upon loss of Dupline carrier
20 mS
Power ON delay
Typical
2 s
Heat power
2 W
Indication
Supply ON
LED green
Dupline carrier
LED yellow
Outputs
LED red 5
Environment
Degree of protection
IP 40
Pollution degree
3 (IEC 60664)
Operating temperature
0 to +50C (+32 to +122F)
Storage temperature
-20 to +60C (-4 to +140F)
Humidity (non condensing)
20 to 80 %
Mechanical resistance
Shock
15 G (11mS)
Vibration
2 G (6 to 55 Hz)
Dimensions
Housing
96 x 96 x 78 mm
Build-in depth
70 mm + wiring
Material
NYROL SE1 GFN2
Weight
300 g
AC Supply
Output
load
AC/DC supply
Panel Cut-out
92 mm