Industrial Relay
Type RCP
Monostable
8 or 11-pin socket mounting
2 or 3 change over contacts
Long life (minimun 100.000 electrical operations)
at 10 A 250 VAC /30 VDC
Switching capacity 12 A (5x10
4
cycles)
AC coils 6 to 230 VAC
DC coils 6 to 110 VDC
Matched sockets available
Standard with LED, Push with arm and Flag
IP 40
Conform to CE low voltage directive
IMQ, UL, TV, CSA approved
RCP
Type
No. of pins
Contact code
Rated coil voltage
DC / AC
Product Description
Ordering Key
RCP 8 002 24 DC
Contact code
002
003
Contact rating
10 A
10 A
Contact configuration
2 change over contacts
(DPDT {2-form C})
3 change over contacts
(3PDT {3-form C})
Type Selection
The RCP relay can be used
for a wide range of industrial
applications.
Available in 2 or 3 change-
over contact configuration,
Octal or Undecal version.
At 20C
At 40C
Nominal
Pick-up
Drop-out
Pick-up
Drop-out
Coil
voltage
voltage
voltage
voltage
voltage
resistance
VDC
VDC
VDC
VDC
VDC
6
4.8
0.6
5.2
0.6
23.5 10%
12
9.6
1.2
10.3
1.3
95.0 10%
24
19.2
2.4
20.7
2.6
430.0 10%
48
38.4
4.8
41.4
5.1
1630.0 15%
60
45.0
6.0
48.6
6.4
3000.0 15%
100
80.0
10.0
86.4
10.8
6800.0 15%
110
88.0
11.0
95.0
11.8
6800.0 15%
Coil Characteristics, DC
At 20C
At 40C
Nominal
Pick-up
Drop-out
Pick-up
Drop-out
Coil
voltage
voltage
voltage
voltage
voltage
resistance
VAC
VAC
VAC
VAC
VAC
6
4.8
1.8
5.2
1.9
40.0 10%
12
9.6
3.6
10.3
3.8
160.0 10%
24
19.2
7.2
20.7
7.7
650.0 10%
48
38.4
14.4
41.4
15.5
2600.0 15%
115/120
88.0
36.0
95.0
38.8
11000.0 15%
230
176.0
72.0
190.0
77.7
11000.0 15%
Coil operating range: see diagram n 1 pag. 18
Coil Characteristics, AC
Specifications are subject to change without notice
17
RCP8 . . . .
RCP11 . . . .
RCP8 . . . .
RCP11 . . . .
Dimensions
35.5
35.5
56
13
8
1
2
3
4
5
6
7
8
1
2
6
7
3
4
5
8
Wiring Diagrams
Industrial Relay
Type RCP
Monostable
35.5
35.5
56
13
8
1
10
2
3
4
5
6
7
8
9
11
3
4
5
8
7
10
2
1
11
6
9
Contact Characteristics
Arrangement
002 / 003
Contact rating
(with resistive load)
10 A - 250 VAC / 30 VDC
UL rating
10 A - 250 VAC / 30VDC
1
/
3
HP at 240 VAC
Usually rating
(1x10
5
ops)
10 A - 250 VAC / 30 VDC
Max. rating
(5x10
4
ops)
12 A - 250 VAC / 30 VDC
Material
Silver alloy
Current
Max. switching current
10 A
Initial contact resistance
50 m
(at 1 A 6 VDC)
Max. switch. voltage
250 VAC / 30 VDC
Max. switch. power
2500 VA / 300 W
Life
Electrical life
1x10
5
ops
Mechanical life
1x10
7
ops
Insulation
Test Voltage (1 min.)
Between coil and contacts
3750 VAC Vr.m.s
Between open contacts
750 VAC Vr.m.s
Contact/Contact
1250 VA Vr.m.s
Initial insulation resistance
500 M
- 500 VAC
Insulation
according to EN61810-5
Rated insulation voltage
250 V
Impulsive insulation voltage
3.6 KV
Pollution degree
2
Overvoltage category
III
General Data
Nominal coil power
1.5 W / 2.5 VA
Operating time
(At nominal voltage)
30 ms max.
Release time
(At nominal voltage)
20 ms max.
Temperature rise
(At nominal voltage)
-40 C to +55 C
Ambient temperature
+50 C
Vibration resistance
10 to 55 Hz 1.5 mm
Shock resistance
Funktional
100 m/s
2
/10 g
Destructive
500 m/s
2
/50 g
Humidity
98%, +40C%
Termination
Octal/Undecal-type plug
Construction
Dust cover
Weight
~ 85 g
0
5 10
50 100
500 1000
0.1
0.5
1
10
5
0
18
Specifications are subject to change without notice
18
Specifications are subject to change without notice
U.S.A.
CANADA
GERMANY
ITALY
Diagrams
0
+10
+20
+30
+40
+50
+60
1.4
1.3
1.2
1.1
1.0
0.9
0.8
0.7
0.6
Approvals
1 Coil Operating
Range
3 Max.
DC load
breaking
capacity
Ambient temperature (C)
U
B
/ U
N
Rated Voltage (V)
Rated Voltage (V)
Rated Current (A)
0
5 10
50 100
500 1000
0.1
0.5
1
10
5
0
Rated Current (A)
AC Resistive load
DC Resistive load
2 Electrical
life
0 1 2 3 4 5 6 7 8 9 10 11 12
10
0.1
0.5
5
0.05
0.01
1
0
0 1 2 3 4 5 6 7 8 9 10 11 12
10
0.1
0.5
5
00.5
00.1
1
0
Switching Current (A)
Switching Current (A)
Number of operations (X 10
6
ops)
Number of operations (X 10
6
ops)
AC inductive load
250 VAC COS
= 0,4
DC inductive load
28 VDC -- = 40ms
L
R
AC inductive load
COS
= 0,4
DC inductive load
-- = 40ms
L
R
DC inductive load
-- = 7ms
L
R
DC resistive load
28 VDC
AC resistive load
250 VAC