ChipFind - документация

Электронный компонент: RN1A48D63

Скачать:  PDF   ZIP
Specifications are subject to change without notice (30.09.2005)
1
AC Solid State Contactor, 1- and 2 poles
Zero switching (RN1A) for heating and
motor applications
Instant-on switching (RN1B)
Rated operational current: 1-pole: 30 A, 50 A and 63 A
2-pole: 2 x 15 A and 2 x 25 A
Rated operational voltage 230 VAC, 400/480 VAC
Transient overvoltage protection built-in
LED-indication
IP 20 protection
DIN-rail mountable
Product Description
Ordering Key
RN 1 A 23 A 50
The SOLITRON Solid State
Contactor is designed for
industrial heating and motor
control applications.
The Solid State Contactor is
capable of switching 1-, 2-,
and 3-phase applications
with loads up to 63 A AC51
load and up to 24 A AC53a
load. The Solid State Con-
tactor is designed for DIN-
rail mounting with integrated
heatsink and overvoltage
protection. The heatsink is
moved to the front for optimal
convection cooling in the
panel. Cable ducting system
will not stop the airflow.
The contactor elements are
soldered directly on to the
direct copper bonded sub-
strate (DCB-technology). AC
or DC controlled versions
are available. Built-in LED
status indication for applied
control voltage.
Solid State Relay
Number of poles
Switching type
A: Zero switching
B: Instant on switching
Rated operational voltage
Control voltage
Rated operational current
Solid State Relays
1- and 2 Pole SOLITRON
With Integrated Heatsink
Type Selection, 1 Pole
Rated operational
Control voltage
Rated operational current
voltage
AC51: 30 A
AC51: 50 A
AC51: 63 A
AC53a: 6 A
AC53a: 12 A
AC53a: 24 A
230 VAC
5-32 VDC
RN 1A23D30
RN 1A23D50
RN 1A23D63
5-32 VDC
RN 1B23D30
RN 1B23D50
RN 1B23D63
24-230 15% VAC/DC
RN 1A23A30
RN 1A23A50
RN 1A23A63
400/480 VAC
5-32 VDC
RN 1A48D30
RN 1A48D50
RN 1A48D63
5-32 VDC
RN 1B48D30
RN 1B48D50
RN 1B48D63
24-230 15% VAC/DC
RN 1A48A30
RN 1A48A50
RN 1A48A63
Type Selection, 2 Pole
Rated operational
Control voltage
Rated operational current
voltage
AC51: 2 x 15 A
AC51: 2 x 25 A
AC53a: 2 x 6 A
AC53a: 2 x 12 A
230 VAC
5-32 VDC
RN 2A23D30
RN 2A23D50
5-32 VDC
RN 2B23D30
RN 2B23D50
24-265 VAC/DC
RN 2A23A30
RN 2A23A50
400/480 VAC
5-32 VDC
RN 2A48D30
RN 2A48D50
5-32 VDC
RN 2B48D30
RN 2B48D50
24-265 VAC/DC
RN 2A48A30
RN 2A48A50
2
Specifications are subject to change without notice (30.09.2005)
General Specifications
RN..23...
RN..48...
Operational voltage range
24 to 265 VAC
42 to 530 VAC
Non-rep. peak voltage
800 V
p
1200 V
p
Varistor voltage
275 VAC
510 VAC
Operational frequency range
45 to 65 Hz
45 to 65 Hz
Power factor at rated voltage
0.5
0.5
Approvals
UL, CSA
UL, CSA
CE-marking
Yes
Yes
Norms fulfilled
EN 60947-1
Low-voltage switchgear and control gear. Part 1- General Rules
EN 61000-6-2
Generic Immunity Standard. Industrial Environment
Input Specifications
RN....D
RN....A..
Rated control voltage range
RN1
5 to 32 VDC
24 to 265 VAC/DC
RN2
2 x 5 to 32 VDC
2 x 24 to 265 VAC/DC
Pick-up voltage
4 VDC
14 VAC/DC
Drop-out voltage
3 VDC
6 VAC/DC
Reverse voltage max.
32 VDC
-
Input current
RN1
< 9 mA
< 12 mA
RN2
< 9 mA per pole
< 12 mA per pole
Response time
Pick-up time max. (50 Hz)
RN.A
10 ms
20 ms
RN.B
< 1 ms
-
Drop-out time max. (50 Hz)
RN.A
10 ms
20 ms
RN.B
10 ms
-
Input-ON indication (LED, green)
Yes
Yes
Output Specifications
RN.....30
RN.....50
RN.....63
Rated operational current
RN1A.. AC51
@Ta=30C
30 A
50 A
63 A
"
@Ta=40C
30 A
50 A
50 A
"
@Ta=50C
23 A
38 A
40 A
"
@Ta=60C
20 A
30 A
30 A
AC53a
@Ta=40C
6 A
12 A
24 A
RN2A.. AC51
@Ta=30C
2 x 15 A
2 x 25 A
-
"
@Ta=40C
2 x 15 A
2 x 25 A
-
"
@Ta=50C
2 x 11.5 A
2 x 19 A
-
"
@Ta=60C
2 x 10 A
2 x 15 A
-
AC53a
@Ta=40C
2 x 6 A
2 x 12 A
-
Zero crossing detection
Yes
Yes
Yes
Min. operational current
200 mA
200 mA
200 mA
Rep. overload current t=1 s
(Tj init.=25C)
55 AACrms
125 AACrms
150 AACrms
Non-rep. surge current t=10 ms
(Tj init.=25C)
300 A
p
580 A
p
1150 A
p
Off-state leakage current,
@ rated voltage and frequency
(Tj.=125C, max.)
< 1 mA
< 1 mA
< 1 mA
I
2
t for fusing t=1 to 10 ms
450 A
2
s
1680 A
2
s
6600 A
2
s
Critical dV/dt off-state
500 V/s
500 V/s
500 V/s
RN 1 A 23 A 50
Specifications are subject to change without notice (30.09.2005)
3
Thermal Specifications
RN.....30
RN.....50
RN.....63
Operational temperature
-20 to +70C (-4 to +158F)
-20 to +70C (-4 to +158F)
-20 to +70C (-4 to +158
0
F)
Storage temperature
-40 to +100C (-40 to +212F)
-40 to +100C (-40 to +212F)
-40 to +100C (-40 to +212F)
Insulation
Rated impulse withstand voltage
Input to output
4000 V
imp
Rated impulse withstand voltage
Output to heatsink
4000 V
imp
Dimensions
Dimensions
(H x W x D)
RN..30
120 x 45 x 110 mm
RN..50
120 x 90 x 110 mm
RN..63
120 x 90 x 110 mm
Housing Specifications
Mounting
DIN-rail 35 mm
Weight with RHN1
470 g
Weight with RHN2
780 g
Housing material
Noryl SEI, GFN1, Black
LED window material
PC Lexan 141R
Base plate
Aluminium, nickel-plated
Potting compound
Polyurethane, Casco Nobel
Terminals
Screw with captive wire
clamp
Control terminals nominal
4 mm
2
or 2 x 2.5 mm
2
AWG 12 or 2 x AWG 14
Min.
0.5 mm
2
, AWG 20
Mounting torque max.
0.6 Nm
Power terminals nominal
10 mm
2
or 2 x 6 mm
2
AWG 6 or 2 x AWG 10
Min.
1 mm
2
, AWG 16
Mounting torque max.
2.0 Nm
Heatsink compound used
Electrolube HTS
Environment Specifications
Humidity max.
95%, no condensation
Wiring Diagrams
RN 1 A 23 A 50
1-pole RN...
2-pole RN...
Control
input
Control
input
Control
input
L+/L A
1
~
- - - /
L-/L A
2
L
1
T
1
~
- - - /
~
- - - /
L+/L A
1
L-/L A
4
L
1
T
1
L
2
T
2
L-/L A
2
L+/L A
3
4
Specifications are subject to change without notice (30.09.2005)
RN 1 A 23 A 50
Functional Diagrams
1-pole RN...
2-pole RN...
Control
input
L+/L
~
- - - /
L-/L
A
1
A
2
L
1
T
1
L
1
T
1
L
2
T
2
A
1
A
2
Control
input 1
Control
input 2
~
- - - /
~
- - - /
L+/L
L-/L
L+/L
L-/L
A
3
A
4
Applications
Single and double pole relay application
Line-Neutral
Line-Line
Double pole relay in
3-phase application
Delta and star application
(Economy Switch)
L
1
L
2
/N
L
1
L
2
L
3
Two single pole relays in
3-phase application
Delta and star.
(Economy Switch)
L
1
L
2
L
3
Terminal Layout
1-pole RN..
2-pole RN..
L
1
A
1
A
3
A
1
L
2
L
1
T
1
A
2
T
1
A
4
A
2
T
2
RN..30
Specifications are subject to change without notice (30.09.2005)
5
Applications (cont.)
RN 1 A 23 A 50
3 single pole relays in
3-phase application
Delta, Star, Star with neutral
Single and double pole relay in
3-phase application
Delta, Star, Star with neutral
Dimensions
L
1
L
2
L
3
N
L
1
L
2
L
3
N
4
120
45
33,7
103
71,6
37
30
20
70
60
4
120
93
72
45
89
103
71,6
37
20
70
30
60
Note: all dimensions in mm
Note: all dimensions in mm
RN..50. RN..63
RN..30