1
Timers
Product Description
Housing
Type/function
Output
Power supply
of operation. Often used where
a signal from a contact or
sensor, etc., starts a conveyor
belt after a given time period.
Time ranges
0.15 - 3 s
Selectable by DIP-switch
0.6 - 12 s
5
- 100 s
40
- 800 s
Time range accuracy
0 to +10% on max.
min. actual time
min. set time
Repeatability deviation
1%
Time variation
Within rated power supply
0.05%/V
and ambient temperature
0.2%/C
Reset
Time and relay
Intercon. pins 5 & 7
pin 5 pos., 24 VDC, 6 mA
Pulse duration
10 ms
Power supply interruption
Min. 200 ms
Sensor supply output
24 VDC, 15 mA
pin 6 & 7
pin 6 pos.
S 111 156
S 111 166
Output
SPDT relay
DPDT relay
Basic electrical insulation
250 VAC (rms) (contact/electronics)
250 VAC (rms) (contacts/elec., contact/contact)
Contact ratings (Ag-CdO)
(micro gap)
(micro gap)
Resistive loads
AC 1
10 A/250 VAC (2500 VA)
8 A/250 VAC (2000 VA)
DC 1
1 A/250 VDC (250 W)
0.4 A/250 VDC (100 W)
or
10 A/25 VDC (250 W)
4 A/25 VDC (100 W)
Small inductive loads
AC 15 2.5 A/230 VAC
2.5 A/230 VAC
DC 13 5 A/24 VDC
5 A/24 VDC
Mechanical life
30 x 10
6
operations
30 x 10
6
operations
Electrical life
AC 1
2.5 x 10
5
operations (at max. load)
2.5 x 10
5
operations (at max. load)
Operating frequency
7200 operations/h
7200 operations/h
Insulation voltages
Rated insulation voltage
2.0 kVAC (rms) (contact/electronics)
2.0 kVAC (rms) (contact/electronics)
Rated transient protection volt. 4 kV (1.2/50 s) (contact/electronics) (IEC 664)
4 kV (1.2/50 s) (contact/electronics) (IEC 664)
Multi delay on operate, plug-
in time relays up to 800 s
covering 4 selectable time
ranges and 4 selectable modes
4 selectable delay on operate functions
4 selectable time ranges: 0.15 s to 800 s
Knob-adjustable time within range
Oscillator-controlled time circuit
Repeatability deviation:
1%
Direct connection for NPN sensor
Output: 10 A SPDT or 8 A DPDT relay
Plug-in type module
S -housing
LED-indication for relay and power supply on
AC or DC power supply
Delay on Operate Multi-function
Type S 111
Plug
Output
Time range
Supply: 24 VAC
Supply: 115 VAC
Supply: 230 VAC
Supply: 24 VDC
Circular
SPDT
0.15 -800 s
S 111 156 024
S 111 156 115
S 111 156 230
S 111 156 724
DPDT
0.15 -800 s
S 111 166 024
S 111 166 115
S 111 166 230
S 111 166 724
Ordering Key
Type Selection
Time Specifications
Output Specifications
S 111 156 024
2
Specifications are subject to change without notice (25.10.99)
S 111
Aut. start - man. restart
The time period starts when
power supply is applied. At
the end of the set time period,
the relay operates. When in-
terconnecting pins 5 and 7
after expiration of the time
period, the relay releases and
a new time period starts.
Aut. start - man. restart
and time reset
The time period starts when
power supply is applied. At
the end of the set time period,
the relay operates. When in-
terconnecting pins 5 and 7
for at least 10 ms during the
time period, the time is reset.
When interconnecting 5 and
7 after expiration of the time
period, the relay releases and
a new time period starts when
pins 5 and 7 are disconnected.
Man. start and restart
The time period starts when
pins 5 and 7 are interconnec-
ted for at least 10 ms. At the
end of the set time period, the
relay operates regardless of
the connection between pins
5 and 7. Renewed connection
between pins 5 and 7 after
expiration of the time period
will release relay and a new
time period will start.
Man. start - man. restart
and time reset
The time period starts when
pins 5 and 7 are disconnec-
ted. At the end of the first set
time period, the relay oper-
ates. When interconnecting
pins 5 and 7 for at least 10 ms
during the time period, the
time is reset. When intercon-
necting pins 5 and 7 after
expiration of the time period,
the relay releases and a new
time period starts, when pins
5 and 7 are disconnected.
Power ON delay
200 ms
Power OFF delay
200 ms
Indication for
Power supply ON
LED, green
Output ON
LED. red
Environment
IP 20 B
Pollution degree
2 (IEC 664)
Operating temperature
-20 to +50C (-4 to +122F)
Storage temperature
-50 to +85C (-58 to +185F)
Weight
AC types
200 g
DC types
125 g
Approvals
UL, CSA
Power supply AC types
Installation cat. III (IEC 664)
Rated operational voltage
through pins 2 & 10
230
230 VAC 15%, 45 to 65 Hz
115
115 VAC 15%, 45 to 65 Hz
024
24 VAC 15%, 45 to 65 Hz
Drop-out tolerance
40 ms
Rated insulation voltage
2.0 kVAC (RMS)
(supply/elec.)
Rated transient protection volt. 4 kV (1.2/50 s)
(line/neutral)
Power supply DC type
Installation cat. III (IEC 664)
Rated operational voltage 724
24 VDC 15% (pin 2 pos.)
Rated insulation voltage
None
Rated transient protection volt. 4 kV (1.2/50 s)
Consumption
AC supply
2.5 VA
DC supply
1.5 W
Selection of time ranges
DIP-switch selector (3 & 4).
0.15 - 3 s
0.6 - 12 s
5
- 100 s
40
- 800 s
Time setting
Knob-adjustable on scale in
per cent of max. time.
DIP-switches for selecting
function and time are placed
behind a small removable front
plate on the time relay.
Sockets
S 411
Hold down spring
HF
Mounting rack
SM 13
Socket covers
BB 4
Potentiometer lock
PL 3
Front mounting bezel
FRS2
3-wire (NPN) inductive, capacitive or photoelectric switches.
For further information refer to "Accessories". For other AC/DC
voltages refer to "General Information".
1 2 3 4
1 2 3 4
Selection of function
DIP-switch selector (1 & 2).
1. Aut. start - man.
restart
2. Aut. start - man.
restart and time reset
3. Man. start and
restart
4. Man. start - man.
restart and time reset.
Supply Specifications
General Specifications
Mode of Operation
Function/Time Setting
Accessories
Specifications are subject to change without notice (25.10.99)
3
S 111
Power supply
Pulse input
1. Relay on
2. Relay on
3. Relay on
4. Relay on
Wiring Diagrams
Power supply
S 111 156, S 111 166
Power supply
S 111 156, S 111 166
Power supply
S 111 156, S 111 166
3-wire
NPN
sensor
Open collector
Contact
Sensor
Mode of Operation