Timers
Multi interval, plug-in time
relay with 4 selectable time
ranges up to 800 s and 4
selectable modes of opera-
Housing
Type/function
Output
Power supply
Plug
Output
Time range
Supply: 24 VAC
Supply: 115 VAC
Supply: 230 VAC
Supply: 24 VDC
Circular
SPDT
0.15 -800 s
S 112 156 024
S 112 156 115
S 112 156 230
S 112 156 724
DPDT
0.15 -800 s
S 112 166 024
S 112 166 115
S 112 166 230
S 112 166 724
tion. Often used for e.g. flush-
ing systems monitored by a
contact, open collector out-
put or sensor.
Time ranges
0.15 - 3 s
Selectable by DIP-switch
0.6 - 12 s
5
- 100 s
40
- 800 s
Time range accuracy
0 to +10% on max.
min. actual time
min.
set time
Repeatability deviation
1%
Time variation
Within rated power supply
0.2%/C
and ambient temperature
0.05%/V
Reset
Time and relay
Intercon. pins 5 & 7
pin 5 pos., 24 VDC, 6 mA
Pulse duration
10 ms
Power supply interruption
min. 200 ms
Sensor supply output
24 VDC, 15 mA
pin 6 & 7
pin 6 pos.
S 112 156
S 112 166
Output
SPDT relay
DPDT relay
Basic electrical insulation
250 VAC (rms) (contact/electronics)
250 VAC (rms) (contacts/elec., contact/contact)
Contact ratings (AgCdO)
(micro gap)
(micro gap)
Resistive loads
AC 1
10 A/250 VAC (2500 VA)
8 A/250 VAC (2000 VA)
DC 1
1 A/250 VDC (250 W)
0.4 A/250 VDC (100 W)
or
10 A/25 VDC (250 W)
4 A/25 VDC (100 W)
Small inductive loads
AC 15
2.5 A/230 VAC
2.5 A/230 VAC
DC 13 5 A/24 VDC
5 A/24 VDC
Mechanical life
30 x 10
6
operations
30 x 10
6
operations
Electrical life
AC 1
2.5 x 10
5
operations (at max. load)
2.5 x 10
5
operations (at max. load)
Operating frequency
7200 operations/h
7200 operations/h
Insulation voltages
Rated insulation voltage
2.0 kVAC (rms) (contact/electronics)
2.0 kVAC (rms) (contact/electronics)
Rated transient protection volt.
4 kV (1.2/50 s) (contact/electronics) (IEC 60664)
4 kV (1.2/50 s) (contact/electronics) (IEC 60664)
4 selectable interval timer functions
4 selectable time ranges: 0.15 s to 800 s
Knob-adjustable time within range
Oscillator-controlled time circuit
Repeatability deviation:
1%
Direct connection for NPN sensor
Output: 10 A SPDT relay or 8 A DPDT relay
Plug-in type module
S-housing
LED-indication for relay and power supply on
AC or DC power supply
Multi Interval
Type S 112
Product Description
Type Selection
Ordering Key
Time Specifications
Output Specifications
S 112 156 024
2
Specifications are subject to change without notice (25.10.99)
S 112
Aut. start - man. restart
The relay operates and the
time period starts when power
supply is applied. At the end
of the set time period, the
relay releases. When inter-
connecting pins 5 and 7 after
expiration of the time period,
the relay operates and a new
time period starts.
Aut. start - man. restart
and time reset
The relay operates and the
time period starts when power
supply is applied. At the end
of the set time period, the
relay releases. When inter-
connecting pins 5 and 7 for at
least 10 ms during the time
period, the time is reset. When
interconnecting pins 5 and 7
after expiration of the time
period, the relay operates and
a new time period starts when
pins 5 and 7 are disconnected.
Man. start and restart
The relay operates and the
time period starts when pins
5 and 7 are interconnected for
at least 10 ms. At the end of
the set time period, the relay
releases regardless of the
interconnection between pins
5 and 7. Renewed connection
between pins 5 and 7 will
cause the relay to operate
and a new time period will
start.
Man. start - man. restart
and time reset
The relay operates when pins
5 and 7 are interconnected.
The time period starts when
pins 5 and 7 are discon-
nected. At the end of the set
time period, the relay re-
leases. When interconnect-
ing pins 5 and 7 for at least 10
ms during the time period, the
time is reset.
Power ON delay
200 ms
Power OFF delay
200 ms
Indication for
Power supply ON
LED, green
Output ON
LED, red
Environment
IP 20 B
Pollution degree
2 (IEC 60664)
Operating temperature
-20 to +50C (-4 to +122F)
Storage temperature
-50 to +85C (-58 to +185F)
Weight
AC types
200 g
DC types
125 g
Approvals
UL, CSA
Power supply AC types
Installation cat. III (IEC 60664)
Rated operational voltage
through pins 2 & 10
230
230 VAC 15%, 45 to 65 Hz
115
115 VAC 15%, 45 to 65 Hz
024
24 VAC 15%, 45 to 65 Hz
Drop-out tolerance
40 ms
Rated insulation voltage
2.0 kVAC (rms)
(supply/elec.)
Rated transient protection volt. 4 kV (1.2/50 s)
(line/neutral)
Power supply DC type
Installation cat. III (IEC 60664)
Rated operational voltage 724
24 VDC 15% (pin 2 pos.)
Rated insulation voltage
None
Rated transient protection volt. 4 kV (1.2/50 s)
Consumption
AC supply
3.0 VA
DC supply
1.5 W
Wiring Diagrams
Power supply
S 112 156, S 112 166
Power supply
S 112 156, S 112 166
Power supply
S 112 156, S 112 166
Open collector
Contact
3-wire
NPN
sensor
Sensor
Supply Specifications
General Specifications
Mode of Operation
Specifications are subject to change without notice (25.10.99)
3
S 112
Selection of time ranges
DIP-switch selector (3 & 4).
0.15 - 3 s
0.6 - 12 s
5
- 100 s
40
- 800 s
Time setting
Knob-adjustable on scale in
per cent of max. time.
DIP-switches for selecting
function and time are placed
behind a small removable
front plate on the time relay.
Sockets
S 411, D 411 B
Hold down spring
HF
Mounting rack
SM 13
Socket covers
BB 4, BB 5B
Potentiometer lock
PL 3
Front mounting bezel
FRS2
3-wire (NPN) inductive, capacitive or photo electric switches.
For further information refer to "Accessories". For other
AC/DC voltages refer to "General Information ".
Power supply
Pulse input
1. Relay on
2. Relay on
3. Relay on
4. Relay on
Selection of function
DIP-switch selector (1 & 2).
1. Aut. start - man.
restart
2. Aut. start - man.
restart and time reset
3. Man. start and
restart
4. Man. start - man.
restart and time reset.
1