ChipFind - документация

Электронный компонент: S1423156724

Скачать:  PDF   ZIP
Specifications are subject to change without notice (25.06.99)
1
Photoelectrics
Amplifier
Type S1423
Product Description
Ordering Key
Type
Multiplex system
Output type
Power supply
Amplifier relay for photoelectric switches
Multiplex system, master/slave 20 ms cycle
Sensitivity range DIP-switch selectable
Sensitivity adjustment by potmeter
Dirt accumulation and alignment control
Modulated and synchronized light
Make and break switching funct. DIP-switch selectable
Rated operational voltage: 24 VDC or VAC, 115 VAC,
230 VAC
Output 10 A/250 V SPDT relay, NPN Alarm
Plug-in module
LED indications: power supply, output, level
Amplifier relay for multiplexed
photoelectric switch system.
Consisting of 1 master and up
to 10 slave amplifiers. No op-
tical crosstalk possible be-
tween high and low range.
Alignment or dirt accumula-
tion and sensitivity level indi-
cation. Make and break
switching function selectable.
Short circuit protected supply
to photoelectric switches.
Type Selection
Plug type
Function
Ordering no.
Ordering no.
Ordering no.
Ordering no.
Supply: 24 VDC
Supply: 24 VAC
Supply: 115 VAC
Supply: 230 VAC
Circular
Multiplex system,
S 1423 156 724
S 1423 156 024
S 1423 156 115
S 1423 156 230
11 pins
(master/slave),
adjustable sensitivity,
dirt accumulation and
alignment indication
Note: Photoelectric switches types M.F to be ordered separately.
Specifications
Rated operational volt.
AC types
(U
B
)
Pins 2 & 10
230
195 to 265 VAC, 45 to 65 Hz
115
98 to 132 VAC, 45 to 65 Hz
024
20.4 to 27.6 VAC, 45 to 65 Hz
Voltage interruption
40 ms
Dielectric voltage
2.0 kVAC (rms)
Rated impulse withstand volt.
4 kV (1.2/50
s)
Rated operational volt.
DC types
(U
B
)
Pins 2 positive &
10 negative
724
20.4 to 27.6 VDC
Dielectric voltage
None
Rated impulse withstand volt.
800 V (1.2/50
s)
Rated operational power
AC supply
2.5 VA
DC supply
1.5 W
Supply to photoelectric switch
Emitter
Pins 5 & 7
Supply voltage (open loop)
8 V square wave
Current
100 mA short-circuit
protected
Output resistance
47
Receiver
Pins 6 & 8
Supply voltage (open loop)
12 VDC
Short-circuit current
18 mA
Input resistance
470
Approvals
UL, CSA
CE-marking
Yes
S142 3 156 724
2
Specifications are subject to change without notice (25.06.99)
S1423
Specifications (cont.)
Multiplex cycle time
20 ms per amplifier relay
Total cycle
1)
=
20 ms x (N
o
amplifiers) +20 ms
Operating frequency of
1
multiplexed system
2 * Total cycle time
Operating frequency (f)
8 Hz, light/dark ratio 1:2
of each amp. while activated
Response time
Equals Multiplex cycle time
Output function
Make and break switching
DIP-switch selectable
Indication
Supply ON
LED, green
Output ON
LED, red
Alignment/dirt accumulation
LED, yellow (steadily on if
(sensitivity level)
sensitivity adjusted properly)
Environment
Overvoltage category
III (IEC 60664)
Degree of protection
IP 20 (IEC 60529, 60947-1)
Pollution degree
3 (IEC 60664/60664A, 60947-1)
Temperature
Operating -20 to
+50C (-4 to +122F)
Storage
-50 to +85C (-58 to +185F)
Weight
AC supply
200 g
DC supply
125 g
1)
If trigger signal out of the last slave amplifier in loop is con-
nected to trigger signal in of the master; otherwise total cyc-
le time = 300 ms (will cause a reset).
Output Specifications
Switching function
Contact output current (1 & 3)
Continuous AC (I
e
)
10 A/250 VAC ohmic load
(2500 VA)
Continuous DC (I
e
)
1 A/250 VDC ohmic load
(250 W)
Contact life mechanical
30 x 10
6
operations
Contact life electrical
2.5 x 10
5
operations
Rated insulation volt. (U
i
)
250 VAC (rms)
Dielectric voltage
2.0 kVAC (rms)
(contact/electronics)
Rated impulse withstand volt. 4 kV (1.2/50
s) contact/
electronics) (IEC 60664)
Sensitivity
2 ranges,
(% of S
n
)
DIP switch selectable
- low sensitivity (25%)
- high sensitivity (100%)
Fine adjustment with
270 turn knob
Note:
Maximum range indi-
cated on photoelectric
switch data sheet in high
sensitivity range only
Operation within low
sensitivity range, increa-
ses ambient light and
crosstalk immunity.
= [Hz]
Truth Table
1)
Operation diagram and truth table valid for an amplifier
during its multiplex activated mode (trigger signal ON).
During standby mode (trigger signal OFF) the amplifier
status is like "no-object-present", e.g. light received.
2)
Under normal operating conditions, the yellow level indi-
cationLED has to be on steadily (bright).
Break switching
Make switching
Object present
Yes
1)
No
No
Yes
1)
No
No
Dirt on lenses,
misaligned or
--
No
Yes
2)
--
No
Yes
2)
sensitivity too low
Output LED red
OFF
ON
ON
ON
OFF
OFF
Level LED yellow OFF
Off
Load
Pins 1&3
N-act.
Active
Active
Active.
N-act.
N-act.
ON
steadily
ON
steadily
OFF or
weakly ON
2)
OFF or
weakly ON
2)
Operation Diagram
Power supply
Object present, light beam interrupted
Output ON: Break switching pin 1, 3*
Make switching pin 1, 3*
*) Switching function selected by DIP-switch, inverted function on pin 1, 4.
Tv
Tv
Specifications are subject to change without notice (25.06.99)
3
Mode of Operation
out) to pin 11 (trigger signal
in). The multiplex cycle is re-
initialized automatically by the
master each 300 ms or,
immediately after the last sla-
ve amplifier in the loop has
been activated, if the trigger
A multiplexed system consists
of 1 master amplifier which
initialises the multiplex cycle
with a trigger signal, and up to
10 slave amplifiers connected
together in a loop via the trig-
ger signal. Pin 9 (trigger signal
output of the last slave ampli-
fier is connected to the trigger
input of the master. Each
photoelectric switch has its
own amplifier with a relay out-
put. A multiplexed system
allows the use of up to 11
long range photoelectric
switches
mounted near one
another, without having false
output signals due to optical
crosstalk.
Dimensions
Supply green
Output red
Sensitivity level yellow
Sensivitiy
adjust.
Switching
function
Sensivity range:
High sensivity (100%)
Low sensivity (25%)
Switching function:
Break switching
Make switching
Master/Slave function:
Master
Slave
Master/
Slave func.
Sensitivity range
Wiring Diagrams
M
S1
S3
7
S2
S10
9
11
S1
S3
S2
S10
7
7
7
9
11
9
11
9
11
9
11
M=Master
S=Slave
Emitter
(grey cable)
Receiver
(black cable)
Trigger out
Trigger common
Trigger in
Parallel string
Master string
Accessories
Delivery Contents
- 11 pole circular socket
S111, S111A, S411, ZPD11
- Socket cover for S111
BB1
- Socket cover for S411
BB4
- Holding down spring
HF
- Mounting rack
SM13
- Front panel mounting bezel
FRS2
- Potentiometer knob lock
PL1
Amplifier
Packaging: styropor box
Power supply
(+)
(-)
~
~
S1423