ChipFind - документация

Электронный компонент: UA18CLD15AG

Скачать:  PDF   ZIP
Specifications are subject to change without notice (22.08.2005)
1
Ultrasonic
Diffuse, Analogue Output
Types UA18CLD..A..., UA30CLD..A...
Cylindrical M18 and M30 polyester housing
Sensing distance: 100-600 mm, 200-1500 mm
or 300-2500 mm
Power supply: 18 to 30 VDC
Output: 0-10 VDC or 4-20 mA
Linearity error 0.3%
Repeatability 0.2%
8 beam angle
Protection: Short-circuit, reverse polarity, transients
Protection degree IP 67
2 m cable or M12 plug
Product Description
Ultrasonic sensor
Housing style
Housing size
Housing material
Housing length
Detection principle
Sensing distance
Output type
Output configuration
Connection
Type Selection
Housing
Body
Connec-
Rated operating
Output
Ordering no.
diameter
style
tion
dist. (S
n
)
M18
Long
Cable
100-600 mm
0-10 V
UA 18 CLD 06 AK
M18
Long
Plug M12
100-600 mm
0-10 V
UA 18 CLD 06 AK M1
M18
Long
Cable
200-1500 mm
0-10 V
UA 18 CLD 15 AK
M18
Long
Plug M12
200-1500 mm
0-10 V
UA 18 CLD 15 AK M1
M18
Long
Cable
100-600 mm
4-20 mA
UA 18 CLD 06 AG
M18
Long
Plug M12
100-600 mm
4-20 mA
UA 18 CLD 06 AG M1
M18
Long
Cable
200-1500 mm
4-20 mA
UA 18 CLD 15 AG
M18
Long
Plug M12
200-1500 mm
4-20 mA
UA 18 CLD 15 AG M1
M30
Long
Cable
300-2500 mm
0-10 V
UA 30 CLD 25 AK
M30
Long
Plug M12
300-2500 mm
0-10 V
UA 30 CLD 25 AK M1
M30
Long
Cable
300-2500 mm
4-20 mA
UA 30 CLD 25 AG
M30
Long
Plug M12
300-2500 mm
4-20 mA
UA 30 CLD 25 AG M1
Ordering Key UA 18 CLD 15 AK M1
A family of diffuse ultrasonic
sensors with sensing range
from 100-600 mm, 200-1500
mm and 300-2500 with a
resolution as low as 0.5 mm.
The outputs are either 0-10V
or 4-20 mA which make it an
ideal choice for distance
measurement, level measure-
ment, diameter measurement
or loop control.
Due to use of microprocessor
control the digital filtering
makes the sensor immune to
most electromagnetic inter-
ferences. The control input
enables synchronisation in an
easy way.
Specifications
Rated operational volt. (U
e
)
18 to 30 VDC
(ripple included)
Ripple
10%
No-load supply current (I
o
)
35 mA
Protection
Short-circuit, transients and
reverse polarity
Rated insulation voltage
> 1 kV
Power ON delay
< 10 ms
Output
UA..CLD..AK..
0-10 VDC
UA..CLD..AG..
4-20 mA
Output slope
K
(mV/mm)
G (
A/mm)
UA18CLD06A ...
20
32
UA18CLD15A ...
5.5
8.8
UA30CLD25A ...
3.7
5.9
Linearity error
< 0.3%
Repeat accuracy (R)
0.2%
Rated operating distance/
Resolution
UA18CLD06A. ..
100-600 mm
10.5 mm
UA18CLD15A. ..
200-1500 mm
10.5 mm
UA30CLD25A. ..
300-2500 mm
10.5 mm
Load
4-20 mA
max. 500
0-10 V
min. 1 k
Carrier frequency
180 KHz
2
Specifications are subject to change without notice (22.08.205)
M18 - Cable
M18 - Plug
Dimensions
UA18CLD..A..., UA30CLD..A...
Wiring Diagram
Specifications (cont.)
Response time
UA18CLD06A. ..
50 ms
UA18CLD15A.
< 100 ms
UA18CLD15A. M1
150 ms
UA30CLD25A. ..
90 ms
Temperature compensation
No
Beam angle
8
Ambient temperature
Operating
-15 to +70C (5 to +158F)
Storage
-25 to +75C (-13 to +167F)
Degree of protection
IP 67 (Nema 1, 3, 4, 6, 13)
Housing material
Polyester PBTP
Connection
Cable
2 m, 4 x 0.25 mm
2
Plug
M12 x 1
Cables for plug M1
CONM14NF serie
Weight
UA 18 ... .. A.
96 g
UA 18 ... .. A. M1
57 g
UA 30 ... .. A.
199 g
UA 30 ... .. A. M1
140 g
Tightening torque
UA 18
2.6 Nm
UA 30
7.5 Nm
CE-marking
Yes
M30 - Cable
M30 - Plug
mA
20
4
200
1500
mA
20
4
100
600
mA
20
4
300
2500
V
10
0
200
1500
V
10
0
100
600
V
10
0
300
2500
1
2
2
2
4
5
Enable
Hold
Not used
Synchronization
3
Sensor
# 1
Sensor
# 10
5
3
2
1
4
Voltage
output:
Current
output:
UA 18 CLD 06 .. ..
UA 18 CLD 15 .. ..
UA 30 CLD 25 .. ..
Specifications are subject to change without notice (22.08.2005)
3
100
600
+100
-100
mm
mm
Installation Hints
Relief of cable strain
Protection of the sensing face
Switch mounted on mobile carrier
To avoid interference from inductive voltage/
current peaks, separate the prox. switch
power cables from any other power cables,
e.g. motor, contactor or solenoid cables
Incorrect
Correct
The cable should not be pulled
A proximity switch should not serve as
mechanical stop
Any repetitive flexing of the
cable should be avoided
Detection Range
200
1500
+100
-100
mm
mm
300
2500
+110
-110
mm
mm
Guaranteed detection of a target 100 x 100 mm
Possible detection of a large target
Guaranteed detection of a target 100 x 100 mm
Possible detection of a large target
Guaranteed detection of a target 100 x 100 mm
Possible detection of a large target
UA18CLD..A..., UA30CLD..A...
UA 18 CLD 06 .. ..
UA 18 CLD 15 .. ..
UA 30 CLD 25 .. ..