ChipFind - документация

Электронный компонент: WM1496AV53BX

Скачать:  PDF   ZIP
Specifications are subject to change without notice WM14-96DS 310706
1
Class 1 (active energy)
Class 2 (reactive energy)
Accuracy 0.5 F.S. (current/voltage)
Power analyzer
Display of instantaneous variables: 3x3 digit
Display of energies: 8+1 digit
System variables and phase measurements: W, W
dmd
,
var, VA, VA
dmd
, PF, V, A, An, A
dmd
, Hz
A
max
, A
dmd max
, W
dmd max
indication
Energy measurements: kWh and kvarh
Hour counter (5+2 DGT)
TRMS meas. of distorted sine waves (voltages/currents)
Power supply: 24V, 48V, 115V, 230V, 50-60Hz; 18 to 60VDC
Protection degree (front): IP65
Front dimensions: 96x96mm
Optional RS422/485 serial port
Product Description
3-phase power analyzer with
built-in programming key-
pad. Particularly recom-
mended for displaying the
main electrical variables.
Housing for panel mounting,
(front) protection degree
IP65, and optional RS485
serial port or dual pulse out-
put. Parameters pro-
grammable by means of
CptBSoft.
Energy Management
Power Analyzer
Type WM14-96 "Basic Version"
Model
Range code
System
Power supply
Option
How to order
WM14-96 AV5 3 D PG
X
Type Selection
Power supply
A:
24VAC
-15+10%, 50-60Hz
B:
48VAC
-15+10%, 50-60Hz
C:
115VAC
-15+10%, 50-60Hz
D:
230VAC
-15+10%, 50-60Hz
3:
18 to 60VDC (not
available in case of
SG or PG options)
Range codes
AV5:
380/660V
L-L
/5(6)AAC
VL-N: 185 V to 460 V
VL-L: 320 V to 800 V
AV6:
120/208V
L-L
/5(6)AAC
VL-N: 45 V to 145 V
VL-L: 78 V to 250 V
Phase current: 0.03A to 6A
Neutral current: 0.09 to 6A
Options
X:
None
S:
RS485 port
SG:
RS485+galvanic insu-
lated measurig inputs
PG:
Dual pulse output +
galvanically insulated
measuring inputs.
System
3 :
1-2-3-phase,
balanced/unbalanced
load,with or without
neutral
Rated inputs
Current "X-S options"
3 (non insulated each other)
Current "SG-PG options"
3 (insulated each other)
Voltage
4
Accuracy (display, RS485)
with CT=1 and VT=1 AV5:
(@25C 5C, R.H.
60%) 1150W-VA-var,
FS:230VLN,
400VLL; AV6: 285W-VA-var,
FS:57VLN, 100VLL
Current
0.25 to 6A: (0.5% FS +1DGT)
0.03A to 0.25A: (0.5%FS+7DGT)
Neutral current
0.25 to 6A: (1.5% FS +1DGT)
0.09A to 0.25A: (0.5%FS+7DGT)
Phase-phase voltage
(1.5% FS +1 DGT)
Phase-neutral voltage
(0.5% FS + 1 DGT)
Active and Apparent power,
0.25 to 6A: (1% FS +1DGT);
0.03A to 0.25A: (1% FS
+5DGT)
Reactive power
0.25 to 6A: (2% FS +1DGT);
0.03A to 0.25A: (2% FS +5DGT)
Active energy "X-S option"
Class 2 (start up "I": 30mA)
Reactive energy "X-S option"
Class 3 (start up "I": 30mA)
Active energy "SG-PG opt."
Class 1 (start up "I": 30mA)
Reactive energy "SG-PG opt."
Class 2 (start up "I": 30mA)
Frequency
0.1Hz (48 to 62Hz)
Additional errors
Humidity
0.3% FS, 60% to 90% RH
Temperature drift
200ppm/C
Sampling rate
1400 samples/s @ 50Hz
1700 samples/s @ 60Hz
Display refresh time
700ms
Display
Type
LED, 14mm
Read-out for instant. var.
3x3 DGT
Read-out for energies
3+3+3 DGT (Max indication:
999 999 99.9)
Input specifications
Optional dual pulse output
Alarms (visual only) V
LN
, An
Optional galvanically insulated measuring inputs
How to order
CptBSoft (compatible only with S or SG options): software
to program the working parameters of the power analyzer
and to read the energy and the instantaneous variables.
CptBSoft



2
Specifications are subject to change without notice WM14-96 DS 310706
WM14-96
Data (bidirectional)
Dynamic (reading only)
System, phase variables and
energies
Static (writing only)
All configuration parameters
Data format
1 bit di start , 8 data bit,
no parity, 1 stop bit
Baud-rate
9600 bit/s
RS422/RS485 (on request)
Type
Multidrop
bidirectional (static and
dynamic variables)
Connections
2 or 4 wires, max. distance
1200m, termination directly
on the instrument
Addresses
1 to 255, key-pad selectable
Protocol
MODBUS/JBUS
RS485 Serial Port Specifications
Digital outputs (on request)
Pulse outputs
Number of outputs
2 (one for kWh one for kvarh)
Number of pulses
From 0.01 to 999 in
compliance with the
following formula:
[Psys max (kW or
kvar)*pulses (pulses/kWh
or kvarh)]
<14400
Output type
Relay
min current: 0.05A@250VAC/30VDC
max current: 5A@250VAC/30VDC
Electrical life: min 2*10
5
cycles
Mechanial life: 5*10
6
cycles
Pulse duration
100ms <120ms (ON)
100ms (OFF)
According to EN622053-31
Insulation
By means of relays,
4000 V
RMS
outputs to
measuring inputs,
4000 V
RMS
output to
supply input.
Insulation between the two
outputs: 1000V
RMS
Dual pulse output
Display (cont.)
Read-out for hour counter
1+3+3 DGT (Max. indication:
9 999 9.99)
Measurements
Current, voltage, power,
power factor, frequency,
energy, TRMS measurement
of distorted waves.
Coupling type
Direct
Crest factor
< 3, max 10A peak
Input impedance
(X-S options)
380/660V
L-L
(AV5)
1 M
5%
120/208V
L-L
(AV6)
453 K
5%
Current
0.02
Input impedance
(PG-SG options)
380/660V
L-L
(AV5)
1 M
1%
120/208V
L-L
(AV6)
1 M
1%
Current
0.02
Frequency
48 to 62 Hz
Overload protection
Continuos voltage/current
1.2 F.S.
For 500ms: voltge/current
2 Un/36A
Input specifications (cont.)
CptBSoft software: parameter programming and reading data
NT/XP.
Working mode
Two different working
modes can be selected:
- management of a local
RS485 network;
- management of
communication from a single
instrument to PC (RS232);
Data access
By means of RS485
serial port.
CptBSoft
Multi language software to
program the working
parameters of the power
analyzer and to read the
energies and the
instantaneous variables.
The program runs under
Windows 95/98/98SE/2000/
Specifications are subject to change without notice WM14-96DS 310706
3
WM14-96
Page 5: An, An Alarm
Page 6: W L1, W L2, W L3
Page 7: PF L1, PF L2, PF L3
Page 8: var L1, var L2, var L3
Page 9: VA L1, VA L2, VA L3
Page 10: VA
, W , var
Page 11: VA dmd, W dmd, Hz
Page 12: W dmd max (*)
Page 13: Wh (*)
Page 14: varh (*)
Page 15: VL-L
, PF ,
VLN Alarm
Page 16: A max (*)
Page 17: A dmd max (*)
Page 18: hour counter (*)
(*) = These variables are
stored in EEPROM when the
instrument is switched off
Alarms
Programmable, for the VL
and
An (neutral current).
Note: the alarm is only visual,
by means of LED on the front
of the instrument.
Reset
Independent
alarm (VL
, An)
max: A dmd, W dmd
all energies (Wh, varh) and
hour counter
Password
Numeric code of max. 3
digits; 2 protection levels
of the programming data
1st level
Password "0", no
protection
2nd level
Password from 1 to 999,
all data are protected
System selection
3-phase with/without n, unbal.
3-phase balanced
3-phase ARON, unbalanced
2-phase
Single phase
Transformer ratio
CT
1 to 999
VT
1.0 to 99.9
Filter
Operating range
0 to 100% of the input
display scale
Filtering coefficient
1 to 16
Filter action
Measurements, alarms,
serial out. (fundamental var: V,
A, W and their derived ones).
Displaying
Up to 3 variables per page
3-phase system with neutral
Page 1: V L1, V L2, V L3
Page 2: V L12, V L23, V L31
Page 3: A L1, A L2, A L3
Page 4: A L1 dmd, A L2 dmd,
A L3 dmd
Software functions
Auxiliary power supply
230VAC
-15 +10%, 50-60Hz
115VAC
-15 +10%, 50-60Hz
48VAC
-15 +10%, 50-60Hz
24VAC
-15 +10%, 50-60Hz
18 to 60VDC
Power consumption
AC: 4.5 VA
DC: 4W
Power Supply Specifications
mesuring inputs and RS485.
4000VAC, 500VDC between
power supply and RS485
Dielectric strength
4000 VAC (for 1 min)
EMC
Emissions
EN50084-1 (class A)
residential environment,
commerce and light industry
Operating
0 to +50C (32 to 122F)
temperature
(RH < 90% non condensing)
Storage
-30 to +60C (-22 to 140F)
temperature
(RH < 90% non condensing)
Installation category
Cat. III (IEC 60664, EN60664)
Insulation (for 1 minute)
4000VAC, 500VDC
between mesuring
inputs and power supply.
500VAC/DC between
General Specifications
4
Specifications are subject to change without notice WM14-96 DS 310706
WM14-96
General Specifications (cont.)
EMC (cont.)
Immunity
EN61000-6-2 (class A)
industrial environment.
Pulse voltage (1.2/50s)
EN61000-4-5
Safety standards
IEC60664, EN60664
Approvals
CE, (cURus, CSA only "X"
and "S" options)
Connections 5(6) A
Screw-type
Max cable cross sect. area
2.5 mm
2
Housing
Dimensions (WxHxD)
96 x 96 x 63 mm
Material
ABS
self-extinguishing: UL 94 V-0
Mounting
Panel
Protection degree
Front: IP65 (standard),
NEMA4x, NEMA12
Connections: IP20
Weight
Approx. 400 g (pack. incl.)
Display variables in 3-phase systems (in a 3-phase system with neutral)
No
1
st
variable
2
nd
variable
3
rd
variable
Note
1
V L1
V L2
V L3
2
V L12
V L23
V L31
Decimal point blinking on the right
of the display
3
A L1
A L2
A L3
4
A L1 dmd
A L2 dmd
A L3 dmd
dmd = demand (integration time
selectable from 1 to 30 minutes)
5
An
AL.n
AL.n if neutral current alarm is
active
6
W L1
W L2
W L3
Decimal point blinking on the right
of the display if generated power
7
PF L1
PF L2
PF L3
8
var L1
var L2
var L3
Decimal point blinking on the right
of the display if generated power
9
VA L1
VA L2
VA L3
10
VA system
W system
var system
11
VA dmd
W dmd
Hz
dmd = demand (integration time
(system)
(system)
(system)
selectable from 1 to 30 minutes)
12
W dmd MAX
Maximum sys power demand
13
Wh (MSD)
Wh
Wh (LSD)
The total indication is given in
max 3 groups of 3 digits.
14
varh (MSD)
varh
varh (LSD)
The total indication is given in
max 3 groups of 3 digits.
15
V LL system
AL.U
PF system
AL.U= is activated only if one of
VLN is not within the set limits.
16
A MAX
max. current among the three phases
17
A dmd max
max. dmd current among the three phases
18
h
hour counter
MSD: most significant digit
LSD: least significant digit
Display pages
al
dmd
M
var
W
V
VA
Hz
L
1
L
3
A
k
PF
h
L
2
1) Example of kWh visualization:
This example is showing 15 933 453.7 kWh
al
dmd
M
var
W
V
VA
Hz
L
1
L
3
A
k
PF
h
L
2
2) Example of kvarh visualization:
This example is showing 3 553 944.9 kvarh
Specifications are subject to change without notice WM14-96DS 310706
5
WM14-96
Used calculation formulas
Instantaneous apparent power
Instantaneous reactive power
System variables
Equivalent 3-phase voltage
3-phase reactive power
Phase variables
Instantaneous effective voltage
Instantaneous active power
Instantaneous power factor
Instantaneous effective current
3-phase active power
3-phase apparent power
3-phase power factor
Neutral current
An = A
L1
+ A
L2
+ A
L3
Waveform of the signals that can be measured
Figure A
Sine wave, undistorted
Fundamental content
100%
Harmonic content
0%
A
rms
=
1.1107 | A |
Figure B
Sine wave, indented
Fundamental content
10...100%
Harmonic content
0...90%
Frequency spectrum: 3rd to 16th harmonic
Additional error: <1% FS
Figure C
Sine wave, distorted
Fundamental content
70...90%
Harmonic content
10...30%
Frequency spectrum: 3rd to 16th harmonic
Additional error: <0.5% FS
Accuracy
kWh, accuracy (RDG) depending on the current
Error
6A (Imax)
6A (Imax)
5A (In)
5A (In)
0.25A
(0.05In)
0.5A
(0.1In)
0.10A
(0.02In)
0.25A
(0.05In)
0%
+2.5%
Class 2 accuracy limits (Active energy)
5(6A) Start-up current: 30mA
kvarh, accuracy (RDG) depending on the current
Error
0%
+4%
Class 3 accuracy limits (Reactive energy)
5(6A) Start-up current: 30mA
PF=1
PF=L0.5
or C0.8
6A (Imax)
6A (Imax)
5A (In)
5A (In)
0.25A
(0.05In)
0.5A
(0.1In)
0.1A
(0.02In)
0.25A
(0.05In)
sin
=1
sin
=0.5
+2%
+1.5%
+1%
+1.5%
-1.5%
PF=1
PF=L0.5
or C0.8
+2.5%
+2%
+3%
+2.5%
+2%
+1.5%
+1%
+ 1%
- 1%
+4%
+3%
+2.5%
+2%
Class 2
Class 1
Class 2
Class 2
Class 3
Class 3
: this graph is only referred to instrument models with the "SG or PG" option.
: this graph is only referred to instrument models with the "X or S" option.
6
Specifications are subject to change without notice WM14-96 DS 310706
WM14-96
Wiring diagrams
ARON and VT connection
3CT and 3VT connection
CT connection
Fig. 3
2-phase connection
3-phase load balanced connection
Fig. 4
Fig. 2
Fig. 1
Fig. 5
Fig. 6
Energy metering
Where:
i = considered phase (L1, L2 or L3)
P = active power
Q = reactive power
t
1
, t
2
= starting and ending time points of consumption recording
n = time unit
t = time interval between two successive power consumptions
n
1
, n
2
= starting and ending discrete time points of consumption recording
Used calculation formulas (cont.)
1-phase connection
NOTE: Only for "PG" and "SG" options: the current measuring inputs are galvanically insulated
and therefore they can be connected to ground singly.
NOTE: For all models except for "PG" or "SG" the current inputs can be connected to the lines
ONLY by means of current transformers. The direct connection is not allowed.
ATTENTION: only one ammeter input can be connected to earth, as shown in the electrical dia-
grams.
Specifications are subject to change without notice WM14-96DS 310706
7
WM14-96
1. Key-pad
To program the configuration parameters and the display of
the variables.
Key to enter programming and confirm selections;
Keys to:
- programme values;
- select functions;
- display measuring pages.
2. Display
LED-type with alphanumeric indications to:
- display configuration parameters;
- display all the measured variables.
L
L
L
L
S
Front Panel Description
1
2
Dimensions and Panel Cut-out
96mm
91mm
61.4mm
15.4mm
9
6
m
m
9
6
m
m
RS485 port connections
Fig. 7: a-Last instrument; b-1...n Instrument
c-RS485/232 serial converter
1
3
-
+
L
N
P
u
l
s
e
1
P
u
l
s
e
2
6 7
8 9
Fig. 8
Dual pulse output connections
1
3
11 12
1314
TX-
RX-
T
GND
RX+
TX+
TX-
RX-
T
GND
RX+
TX+
RX-
TX-
GND
TX+
RX+
RS485 RS232
PC
9
10
11
12
13
14
9
10
11
12
13
14
[a]
[b]
[c]
TX-
RX-
T
GND
RX+
TX+
TX-
RX-
T
GND
RX+
TX+
RX-
TX-
GND
TX+
RX+
RS485 RS232
PC
9
10
11
12
13
14
9
10
11
12
13
14
[a]
[b]
[c]
4-wire
connection
2-wire
connection