ChipFind - документация

Электронный компонент: LBA110PLTR

Скачать:  PDF   ZIP
1
www.clare.com
LBA110L
DS-LBA110L-R3
LBA110L is 350V, 120mA, 35
independent 1-Form-A
and 1-Form-B relays. It is designed to provide an ideal
solution where a complimentary Form-A/Form-B relay
pair is required. Current limiting version is available ("L"
suffix).
Telecommunications
Telecom Switching
Tip/Ring Circuits
Modem Switching (Laptop, Notebook, Pocket Size)
Hookswitch
Dial Pulsing
Ground Start
Ringer Injection
Instrumentation
Multiplexers
Data Acquisition
Electronic Switching
I/O Subsystems
Meters (Watt-Hour, Water, Gas)
Medical Equipment-Patient/Equipment Isolation
Security
Aerospace
Industrial Controls
UL Recognized: File Number E76270
CSA Certified: File Number LR 43639-10
BSI Certified to:
BS EN 60950:1992 (BS7002:1992)
Certificate #: 7344
BS EN 41003:1993
Certificate #: 7344
Small 8 Pin DIP Package
Low Drive Power Requirements (TTL/CMOS
Compatible)
No Moving Parts
High Reliability
Arc-Free With No Snubbing Circuits
3750V
RMS
Input/Output Isolation
FCC Compatible
VDE Compatible
No EMI/RFI Generation
Machine Insertable, Wave Solderable
Current Limiting Surface Mount and Tape & Reel
Versions Available
Applications
Features
Description
Approvals
DUAL POLE OptoMOS
Relay
Ordering Information
Part #
Description
LBA110L
8 Pin DIP (50/Tube)
LBA110PL
8 Pin Flatpack (50/Tube)
LBA110PLTR
8 Pin Flatpack (1000/Reel)
LBA110LS
8 Pin Surface Mount (50/Tube)
LBA110LSTR
8 Pin Surface Mount (1000/Reel)
LBA110L
Units
Load Voltage
350
V
Load Current
120
mA
Max R
ON
35
Pin Configuration
Switching Characteristics of
Normally Closed (Form B) Devices
CONTROL
10ms
10%
90%
90%
+
+
T
ON
T
OFF
+
Switching Characteristics of
Normally Open (Form A) Devices
CONTROL
LOAD
10ms
10%
10%
90%
+
T
ON
T
OFF
+
+
1
2
3
4
8
7
6
5
LBA110L Pinout
+ Control - Normally Closed
Control - Normally Closed
+ Control - Normally Open
Control - Normally Open
Normally Closed Pole
Normally Open Pole
AC/DC Configuration
www.clare.com
LBA110L
Rev. 3
Absolute Maximum Ratings are stress ratings. Stresses
in excess of these ratings can cause permanent damage
to the device. Functional operation of the device at these
or any other conditions beyond those indicated in the
operational sections of this data sheet is not implied.
Exposure of the device to the absolute maximum ratings
for an extended period may degrade the device and effect
its reliability.
Absolute Maximum Ratings (@ 25 C)
2
Parameter
Min
Typ
Max Units
Input Power Dissipation
-
-
150
1
mW
Input Control Current
-
-
50
mA
Peak (10ms)
-
-
1
A
Reverse Input Voltage
-
-
5
V
Total Power Dissipation
-
-
800
2
mW
Isolation Voltage
Input to Output
3750
-
-
V
RMS
Operational Temperature
-40
-
+85
C
Storage Temperature
-40
-
+125
C
Soldering Temperature
DIP Package
-
-
+260
C
Flatpack/Surface Mount
Package
-
-
+220
C
(10 Seconds Max.)
1
Derate Linearly 1.33 mw/C
2
Derate Linearly 6.67 mw/C
Electrical Characteristics
Parameter
Conditions
Symbol
Min
Typ
Max
Units
Output Characteristics @ 25C
Load Voltage (Peak)
-
V
L
-
-
350
V
Load Current *(Continuous)
AC/DC Configuration
-
I
L
-
-
120
mA
Peak Load Current
10ms
I
LPK
-
-
-
mA
On-Resistance
AC/DC Configuration
I
L
=120mA
R
ON
-
23
35
Off-State Leakage Current
V
L
=350V
I
LEAK
-
-
1
A
Switching Speeds
Turn-On
I
F
=5mA, V
L
=10V
T
ON
-
-
3
ms
Turn-Off
I
F
=5mA, V
L
=10V
T
OFF
-
-
3
ms
Output Capacitance
50V; f=1MHz
C
OUT
-
25
-
pF
Load Current Limiting
Form A only
I
CL
130
170
210
mA
Input Characteristics @ 25C
Input Control Current
I
L
=Load Current
I
F
5
-
50
mA
Input Dropout Current
-
I
F
0.4
0.7
-
mA
Input Voltage Drop
I
F
=5mA
V
F
0.9
1.2
1.4
V
Reverse Input Voltage
-
V
R
-
-
5
V
Reverse Input Current
V
R
=5V
I
R
-
-
10
A
Input to Output Capacitance
-
C
I/O
-
3
-
pF
Input to Output Isolation
-
V
I/O
3750
-
-
V
RMS
*NOTE: If both poles operate simultaneously load current must be derated so as not to exceed the package power dissipation value.
LBA110L
www.clare.com
Rev. 3
PERFORMANCE DATA*
The Performance data shown in the graphs above is typical of device performance. For guaranteed parameters not indicated in the written specifications, please contact
our application department.
3
LBA110L
Typical LED Forward Voltage Drop
(N=50 Ambient Temperature = 25
C; I
F
= 5mADC)
35
30
25
20
15
10
5
0
1.17
1.19
1.21
1.23
1.25
LED Forward Voltage Drop (V)
Device Count (N)
LBA110L - FormA
Typical On-Resistance Distribution
(N=50 Ambient Temperature = 25
C)
(Load Current = 120mADC, I
F
=5mADC)
35
30
25
20
15
10
5
0
15.8
16.4
17.0
17.6
16.1
16.7
17.3
On-Resistance (
)
Device Count (N)
LBA110L - FormB
Typical On-Resistance Distribution
(N=50 Ambient Temperature = 25
C)
(Load Current = 120mADC, I
F
=5mADC)
30
25
20
15
10
5
0
27.8
29.2
30.6
32.0
28.5
29.9
31.3
On-Resistance (
)
Device Count (N)
LBA110L - FormA
Typical Blocking Voltage Distribution
(N=50 Ambient Temperature = 25
C)
35
30
25
20
15
10
5
0
376.8
379.8
382.8
385.8
378.3
381.3
384.3
Blocking Voltage (V)
Device Count (N)
LBA110L - FormB
Typical Blocking Voltage Distribution
(N=50 Ambient Temperature = 25
C)
30
25
20
15
10
5
0
386.3
391.3
396.3
401.3
388.8
393.8
398.8
Blocking Voltage (V)
Device Count (N)
LBA110L - FormA
Typical I
F
for Switch Dropout
(N=50 Ambient Temperature = 25
C)
(Load Current = 120mADC)
25
20
15
10
5
0
0.45
1.05
1.65
0.15
0.75
1.35
1.95
LED Current (mA)
Device Count (N)
LBA110L - FormA
Typical I
F
for Switch Operation
(N=50 Ambient Temperature = 25
C)
(Load Current = 120mADC)
0.5
0.9
1.3
0.7
1.1
1.5
LED Current (mA)
Device Count (N)
25
20
15
10
5
0
LBA110L - FormB
Typical I
F
for Switch Operation
(N=50 Ambient Temperature = 25
C)
(Load Current = 120mADC)
30
25
20
15
10
5
0
0.7
1.1
1.5
1.9
1.3
LED Current (mA)
Device Count (N)
LBA110L - FormB
Typical I
F
for Switch Dropout
(N=50 Ambient Temperature = 25
C)
(Load Current = 120mADC)
25
20
15
10
5
0
0.45
0.65
0.85
0.35
0.55
0.75
0.95
LED Current (mA)
Device Count (N)
LBA110L - FormA
Typical Turn-On Time
(N=50 Ambient Temperature = 25
C)
(Load Current = 120mADC; I
F
= 5mADC)
0.15
0.35
0.65
0.25
0.45
Turn-On (ms)
Device Count (N)
25
20
15
10
5
0
0.55
LBA110L - FormB
Typical Turn-On Time
(N=50 Ambient Temperature = 25
C)
(Load Current = 120mADC; I
F
= 5mADC)
0.10
0.18
0.26
0.14
0.22
0.30
Turn-On (ms)
Device Count (N)
30
25
20
15
10
5
0
LBA110L - FormA
Typical Turn-Off Time
(N=50 Ambient Temperature = 25
C)
(Load Current = 120mADC; I
F
= 5mADC)
0.03
0.13
0.23
0.18
0.08
Turn-Off (ms)
Device Count (N)
25
20
15
10
5
0
www.clare.com
4
LBA110
Rev. 3
PERFORMANCE DATA*
*The Performance data shown in the graphs above is typical of device performance. For guaranteed parameters not indicated in the written specifications, please contact
our application department.
LBA110L - FormB
Typical Turn-Off Time
(N=50 Ambient Temperature = 25
C)
(Load Current = 120mADC; I
F
= 5mADC)
0.35
0.55
0.75
0.65
0.45
0.25
Turn-Off (ms)
Device Count (N)
30
25
20
15
10
5
0
LBA110L - Form A
Typical Load Current vs. Temperature
Temperature (
C)
Load Current (mA)
180
160
140
120
100
80
60
40
20
0
-40
-20
0
20
40
60
80
120
100
20mA
10mA
5mA
LBA110L - Form B
Typical Load Current vs. Temperature
Temperature (
C)
Load Current (mA)
180
160
140
120
100
80
60
40
20
0
-40
-20
0
20
40
60
80
120
100
5mA
LBA110L
Typical Leakage vs. Temperature
(Measured across Pins 5 & 6 or 7 & 8)
Temperature (
C)
Leakage (
A)
-40
0.030
0.025
0.020
0.015
0.010
0.005
0
-20
0
20
40
60
80
100
LBA110L - FormA
Typical Blocking Voltage vs. Temperature
Temperature (
C)
Blocking Voltage (V
RMS
)
-40
400
395
390
385
380
375
370
365
360
355
-20
0
20
40
60
80
100
LBA110L - FormB
Typical Blocking Voltage vs. Temperature
Temperature (
C)
Blocking Voltage (V
RMS
)
-40
410
405
400
395
390
385
380
375
370
365
360
-20
0
20
40
60
80
100
LBA110L - FormA
Typical Turn-On vs. Temperature
(Load Current = 120mADC)
Temperature (
C)
Turn-On (ms)
-40
0.50
0.45
0.40
0.35
0.30
0.25
0.20
0.15
-20
0
20
40
60
80
100
5mA
10mA
20mA
LBA110L - FormB
Typical Turn-On vs. Temperature
(Load Current = 120mADC)
Temperature (
C)
Turn-On (ms)
-40
0.35
0.30
0.25
0.20
0.15
0.10
0.05
0
-20
0
20
40
60
80
100
5mA
LBA110L - FormA
Typical Turn-Off vs. Temperature
(Load Current = 120mADC)
Temperature (
C)
Turn-Off (ms)
-40
0.20
0.18
0.16
0.14
0.12
0.10
0.08
0.06
0.04
0.02
0
-20
0
20
40
60
80
100
5mA
LBA110L - FormB
Typical Turn-Off vs. Temperature
(Load Current = 120mADC)
Temperature (
C)
Turn-Off (ms)
-40
0.7
0.6
0.5
0.4
0.3
0.2
0.1
-20
0
20
40
60
80
100
5mA
10mA
20mA
LBA110L
Typical LED Forward Voltage Drop
vs. Temperature
Temperature (
C)
LED Forward Voltage Drop (V)
1.8
1.6
1.4
1.2
1.0
0.8
-40
-20
0
20
40
60
80
120
100
50mA
30mA
20mA
10mA
5mA
LBA110L - FormA
Typical Turn-On vs. LED Forward Current
(Load Current = 120mADC)
LED Forward Current (mA)
Turn-On (ms)
0
5
10
15
20
25
30
35
40
45
0.40
0.35
0.30
0.25
0.20
0.15
0.10
50
LBA110L
www.clare.com
5
Rev. 3
PERFORMANCE DATA*
*The Performance data shown in the graphs above is typical of device performance. For guaranteed parameters not indicated in the written specifications, please contact
our application department.
LBA110L - FormB
Typical Turn-On vs. LED Forward Current
(Load Current = 120mADC)
LED Forward Current (mA)
Turn-On (ms)
0
5
10
15
20
25
30
35
40
45
0.25
0.20
0.15
0.10
0.05
50
LBA110L - FormA
Typical Turn-Off vs. LED Forward Current
(Load Current = 120mADC)
LED Forward Current (mA)
Turn-Off (ms)
0
5
10
15
20
25
30
35
40
45
0.092
0.090
0.088
0.086
0.084
0.082
0.080
0.078
0.076
0.074
50
LBA110L - FormB
Typical Turn-Off vs. LED Forward Current
(Load Current = 120mADC)
LED Forward Current (mA)
Turn-Off (ms)
0
5
10
15
20
25
30
35
40
45
0.7
0.6
0.5
0.4
0.3
0.2
0.1
0
50
LBA110L - FormA
Typical On-Resistance vs. Temperature
(Load Current = 120mADC; I
F
= 5mADC)
Temperature (
C)
On-Resistance (
)
-40
20
18
16
14
12
10
8
-20
0
20
40
60
80
100
LBA110L - FormB
Typical On-Resistance vs. Temperature
(Load Current = 120mADC; I
F
= 5mADC)
Temperature (
C)
On-Resistance (
)
-40
60
50
40
30
20
10
0
-20
0
20
40
60
80
100
LBA110L - FormA
Typical I
F
for Switch Operation vs. Temperature
(Load Current = 120mADC)
Temperature (
C)
LED Current (mA)
-40
2.500
2.000
1.500
1.000
0.500
0
-20
0
20
40
60
80
100
LBA110L - FormB
Typical I
F
for Switch Operation vs. Temperature
(Load Current = 120mADC)
Temperature (
C)
LED Current (mA)
-40
3.000
2.500
2.000
1.500
1.000
0.500
0
-20
0
20
40
60
80
100
LBA110L - FormA
Typical I
F
for Switch Dropout vs. Temperature
(Load Current = 120mADC)
Temperature (
C)
LED Current (mA)
-40
2.500
2.000
1.500
1.000
0.500
0
-20
0
20
40
60
80
100
LBA110L - FormB
Typical I
F
for Switch Dropout vs. Temperature
(Load Current = 120mADC)
Temperature (
C)
LED Current (mA)
-40
3.0
2.5
2.0
1.5
1.0
0.5
0
-20
0
20
40
60
80
100
LBA110L - FormA
Typical Load Current vs. Load Voltage
(Ambient Temperature = 25
C; I
F
= 5mADC)
Load Voltage (V)
Load Current (mA)
150
100
50
0
-50
-100
-150
-2.0
-1.5
-0.5
-1.0
0
0.5
1.0
1.5
2.0
LBA110L - FormB
Typical Load Current vs. Load Voltage
(Ambient Temperature = 25
C; I
F
= 5mADC)
Load Voltage (V)
Load Current (mA)
150
100
50
0
-50
-100
-150
-4
-3
-1
-2
0
1
2
3
4
LBA110L
Energy Rating Curve
Time
Load Current (A)
10
s
1.0
0.9
0.8
0.7
0.6
0.5
0.4
0.3
0.2
0.1
0
1ms
100
s
100ms
1s
10ms
10s
100s
LBA110L
Typical Current Limiting Characteristics
vs. Temperature
I
F
= 5mA
Temperature (
C)
Current Limit (mA)
-40
250
200
150
100
50
0
-20
0
20
40
60
80
100