MODEL
RMC15A-1
RMC15A-2
DC OUTPUT
V1
+5V 2.0A
+5V 2.0A
V2
+12V 0.3A
+15V 0.2A
V3
-12V 0.2A
-15V 0.2A
SPECIFICATIONS
MODEL
RMC15A-1
RMC15A-2
INPUT
VOLTAGE[V]
AC85 - 132 1
f
or DC110 - 170
CURRENT[A]
ACIN 100V 0.45typ (Io=100%)
FREQUENCY[Hz]
47 - 440 or DC
EFFICIENCY[%]
ACIN 100V 65typ (Io=100%)
INRUSH CURRENT[A] ACIN 100V 20typ (Io=100%) (At cold start)
OUTPUT
VOLTAGE[V]
+5
+12
-12
+5
+15
-15
CURRENT[A]
0 - 2.0
0 - 0.3
0 - 0.2
0 - 2.0
0 - 0.2
0 - 0.2
LINE REGULATION[mV]
20max
48max
48max
20max
60max
60max
LOAD REGULATION[mV] 100max
120max
120max
100max
150max
150max
RIPPLE[mVp-p]
0 to +50
C
*
1
100max
120max
120max
100max
120max
120max
-10 - 0
C
*
1
150max
160max
160max
150max
160max
160max
RIPPLE NOISE[mVp-p]
0 to +50
C
*
1
120max
150max
150max
120max
150max
150max
-10 - 0
C
*
1
170max
180max
180max
170max
180max
180max
TEMPERATURE REGULATION[mV]
0 to +50
C
50max
350max
350max
50max
350max
350max
-10 to +50
C
60max
420max
420max
60max
420max
420max
START-UP TIME[ms]
100max (ACIN 85V, Io=100%)
HOLD-UP TIME[ms]
10typ (ACIN 85V, Io=100%, 0 to +50
C
) 20typ (ACIN 100V, Io=100%, 0 to +50
C
)
OUTPUT VOLTAGE ADJUSTMENT RANGE[V] 5.00 - 5.25
Fixed
Fixed
5.00 - 5.25
Fixed
Fixed
OUTPUT VOLTAGE SETTING[V]
xx
11.40 to 12.60
-11.40 to -12.60
xx
14.25 to 15.74
-14.25 to -15.75
PROTECTION
CIRCUIT
OVERCURRENT PROTECTION Works over 105% of rating and recovers automatically
OVERVOLTAGE PROTECTION
By zerer diode clamping (+5V only)
OPERATING INDICATION LED (Green)
ISOLATION
INPUT-OUTPUT
AC2,000V 1minute, DC500V 50M
W
min (At Room Temperature)
INPUT-FG, COVER
AC2,000V 1minute, DC500V 50M
W
min (At Room Temperature)
OUTPUT-FG, COVER
AC500V 1minute, DC500V 50M
W
min (At Room Temperature)
OUTPUT-OUTPUT(V1-V2,V3) AC100V 1minute, DC100V 10M
W
min (At Room Temperature)
ENVIRONMENT
OPERATING TEMP.,HUMID.AND ALTITUDE -10 to +60
C
, 20 - 90%RH (Non condensing) (Refer to DERATING CURVE), 3,000m (10,000feet) max
STORAGE TEMP.,HUMID.AND ALTITUDE -20 to +75
C
, 20 - 90%RH (Non condensing), 9,000m (30,000feet) max
VIBRATION
10 - 55Hz, 19.6m/s
2
(2G), 3minutes period, 60minutes each along X, Y and Z axis
IMPACT
196.1m/s
2
(20G), 11ms, once each X, Y and Z axis
SAFETY AND
NOISE
REGULATIONS
AGENCY APPROVALS
UL60950-1, C-UL Complies with DEN-AN
CONDUCTED NOISE
Complies with FCC-B, VCCI-B
OTHERS
CASE SIZE/WEIGHT
28
X
80
X
100mm (W
X
H
X
D) /250g max (without cover)
COOLING METHOD
Convection
*
1
Measured by 20MHz oscilloscope or Ripple-Noise meter(equivalent to KEISOKU-GIKEN : RM101).
*
Series/Parallel operation with other model is not possible.
*
When units are operated with chassis and cover, derating is required.
RMC15A
Unit type
RMC 15A
-1
-
O
Ordering information
1
Series name
2
Output wattage
3
Output voltage combina-
tion
4
Optional
C :with Coating
G :Low leakage current
J :Connector type
N :with Cover
R
1
2
3
4
RMC
B-24
DERATING CURVE
OVERCURRENT CHARACTERISTICS (RMC15A-1)
RISE TIME & FALL TIME (RMC15A-1)
STATIC CHARACTERISTICS (RMC15A-1)
OUTPUT VOL
T
AGE
V
INPUT VOLTAGE
V 60Hz
Io=100%
Ripple
Output Voltage
RIPPLE
mVp-p
40
10
0
50
60
70
80
90
100 110 120 130
20
30
40
50
60
13.0
12.0
11.0
10.0
9.0
8.0
5.2
5.0
4.8
4.6
4.4
4.2
+12V
+5V
+5V
+12V
-12V
-12V
RMC
B-25
RMC15A
External view
Connector type
Barrier strip type
Performance data
MODEL
RMC30A-1
RMC30A-2
DC OUTPUT
V1
+5V 3.0A
+5V 3.0A
V2
+12V 1.2A
+15V 0.5A
V3
-12V 0.3A
-15V 0.5A
SPECIFICATIONS
MODEL
RMC30A-1
RMC30A-2
INPUT
VOLTAGE[V]
AC85 - 132 1
f
or DC110 - 170
CURRENT[A]
ACIN 100V 0.9typ (Io=100%)
FREQUENCY[Hz]
47 - 440 or DC
EFFICIENCY[%]
ACIN 100V 67typ (Io=100%)
INRUSH CURRENT[A] ACIN 100V 30typ (Io=100%) (At cold start)
OUTPUT
VOLTAGE[V]
+5
+12
-12
+5
+15
-15
CURRENT[A]
0 - 3.0
0 - 1.2
0 - 0.3
0 - 3.0
0 - 0.5
0 - 0.5
LINE REGULATION[mV]
20max
48max
48max
20max
60max
60max
LOAD REGULATION[mV] 100max
120max
150max
100max
120max
150max
RIPPLE[mVp-p]
0 to +50
C
*
1
100max
120max
120max
100max
120max
120max
-10 - 0
C
*
1
150max
160max
160max
150max
160max
160max
RIPPLE NOISE[mVp-p]
0 to +50
C
*
1
120max
150max
150max
120max
150max
150max
-10 - 0
C
*
1
170max
180max
180max
170max
180max
180max
TEMPERATURE REGULATION[mV]
0 to +50
C
50max
350max
350max
50max
350max
350max
-10 to +50
C
60max
420max
420max
60max
420max
420max
START-UP TIME[ms]
100max (ACIN 85V, Io=100%)
HOLD-UP TIME[ms]
10typ (ACIN 85V, Io=100%, 0 to +50
C
) 20typ (ACIN 100V, Io=100%, 0 to +50
C
)
OUTPUT VOLTAGE ADJUSTMENT RANGE[V] 5.00 - 5.25
Fixed
Fixed
5.00 - 5.25
Fixed
Fixed
OUTPUT VOLTAGE SETTING[V]
xx
11.40 to 12.60
-11.40 to -12.60
xx
14.25 to 15.75
-14.25 to -15.75
PROTECTION
CIRCUIT
OVERCURRENT PROTECTION Works over 105% of rating and recovers automatically
OVERVOLTAGE PROTECTION
Works at 115 - 140% of rating (+5V)
OPERATING INDICATION LED (Green)
ISOLATION
INPUT-OUTPUT
AC2,000V 1minute, DC500V 50M
W
min (At Room Temperature)
INPUT-FG, COVER
AC2,000V 1minute, DC500V 50M
W
min (At Room Temperature)
OUTPUT-FG, COVER
AC500V 1minute, DC500V 50M
W
min (At Room Temperature)
OUTPUT-OUTPUT(V1-V2,V3) AC100V 1minute, DC100V 10M
W
min (At Room Temperature)
ENVIRONMENT
OPERATING TEMP.,HUMID.AND ALTITUDE -10 to +60
C
, 20 - 90%RH (Non condensing) (Refer to DERATING CURVE), 3,000m (10,000feet) max
STORAGE TEMP.,HUMID.AND ALTITUDE -20 to +75
C
, 20 - 90%RH (Non condensing), 9,000m (30,000feet) max
VIBRATION
10 - 55Hz, 19.6m/s
2
(2G), 3minutes period, 60minutes each along X, Y and Z axis
IMPACT
196.1m/s
2
(20G), 11ms, once each X, Y and Z axis
SAFETY AND
NOISE
REGULATIONS
AGENCY APPROVALS
UL60950-1, C-UL Complies with DEN-AN
CONDUCTED NOISE
Complies with FCC-B, VCCI-B
OTHERS
CASE SIZE/WEIGHT
31
X
80
X
135mm (W
X
H
X
D)/350g max (without cover)
COOLING METHOD
Convection
*
1
Measured by 20MHz oscilloscope or Ripple-Noise meter(equivalent to KEISOKU-GIKEN : RM101).
*
Series/Parallel operation with other model is not possible.
*
When units are operated with chassis and cover, derating is required.
RMC30A
Unit type
RMC 30A
-1
-
O
Ordering information
1
Series name
2
Output wattage
3
Output voltage combina-
tion
4
Optional
G :Low leakage current
J :Connector type
N :with Cover
R
1
2
3
4
RMC
B-26
DERATING CURVE
OVERCURRENT CHARACTERISTICS (RMC30A-1)
RISE TIME & FALL TIME (RMC30A-1)
STATIC CHARACTERISTICS (RMC30A-1)
RMC
B-27
RMC30A
External view
Connector type
Barrier strip type
Performance data
MODEL
RMC50A-1
RMC50A-2
DC OUTPUT
V1
+5V 5.0A
+5V 5.0A
V2
+12V 1.5(Peak 2)A
+15V 1.2A
V3
-12V 0.5A
-15V 0.5A
SPECIFICATIONS
MODEL
RMC50A-1
RMC50A-2
INPUT
VOLTAGE[V]
AC85 - 132 1
f
or DC110 - 170
CURRENT[A]
ACIN 100V 1.5typ (Io=100%)
FREQUENCY[Hz]
47 - 440 or DC
EFFICIENCY[%]
ACIN 100V 70typ (Io=100%)
INRUSH CURRENT[A] ACIN 100V 30typ (Io=100%) (At cold start)
OUTPUT
VOLTAGE[V]
+5
+12
-12
+5
+15
-15
CURRENT[A]
*
1
0 - 5.0
0 - 1.5 (Peak 2) 0 - 0.5
0 - 5.0
0 - 1.2
0 - 0.5
LINE REGULATION[mV]
20max
48max
48max
20max
60max
60max
LOAD REGULATION[mV] 40max
150max
150max
40max
150max
150max
RIPPLE[mVp-p]
0 to +50
C
*
2
80max
120max
120max
80max
120max
120max
-10 - 0
C
*
2
140max
160max
160max
140max
160max
160max
RIPPLE NOISE[mVp-p]
0 to +50
C
*
2
120max
150max
150max
120max
150max
150max
-10 - 0
C
*
2
160max
180max
180max
160max
180max
180max
TEMPERATURE REGULATION[mV]
0 to +50
C
50max
350max
350max
50max
350max
350max
-10 to +50
C
60max
420max
420max
60max
420max
420max
START-UP TIME[ms]
100max (ACIN 85V, Io=100%)
HOLD-UP TIME[ms]
10typ (ACIN 85V, Io=100%, 0 to +50
C
) 20typ (ACIN 100V, Io=100%, 0 to +50
C
)
OUTPUT VOLTAGE ADJUSTMENT RANGE[V] 5.00 - 5.25
Fixed
Fixed
5.00 - 5.25
Fixed
Fixed
OUTPUT VOLTAGE SETTING[V]
xx
11.40 to 12.60
-11.40 to -12.60
xx
14.25 to 15.75
-14.25 to -15.75
PROTECTION
CIRCUIT
OVERCURRENT PROTECTION Works over 105% of rating and recovers automatically
OVERVOLTAGE PROTECTION
Works at 115 - 140% of rating (+5V)
OPERATING INDICATION LED (Green)
ISOLATION
INPUT-OUTPUT
AC2,000V 1minute, DC500V 50M
W
min (At Room Temperature)
INPUT-FG, COVER
AC2,000V 1minute, DC500V 50M
W
min (At Room Temperature)
OUTPUT-FG, COVER
AC500V 1minute, DC500V 50M
W
min (At Room Temperature)
OUTPUT-OUTPUT(V1-V2,V3) AC100V 1minute, DC100V 10M
W
min (At Room Temperature)
ENVIRONMENT
OPERATING TEMP.,HUMID.AND ALTITUDE -10 to +65
C
, 20 - 90%RH (Non condensing) (Refer to DERATING CURVE), 3,000m (10,000feet) max
STORAGE TEMP.,HUMID.AND ALTITUDE -20 to +75
C
, 20 - 90%RH (Non condensing), 9,000m (30,000feet) max
VIBRATION
10 - 55Hz, 19.6m/s
2
(2G), 3minutes period, 60minutes each along X, Y and Z axis
IMPACT
196.1m/s
2
(20G), 11ms, once each X, Y and Z axis
SAFETY AND
NOISE
REGULATIONS
AGENCY APPROVALS
UL60950-1, C-UL Complies with DEN-AN
CONDUCTED NOISE
Complies with FCC-B, VCCI-B
OTHERS
CASE SIZE/WEIGHT
31
X
93
X
155mm (W
X
H
X
D) /350g max (without cover)
COOLING METHOD
Convection
*
1
Peak load current of V2 for RMC50A-1 is possible to draw 30 seconds.
*
2
Measured by 20MHz oscilloscope or Ripple-Noise meter(equivalent to KEISOKU-GIKEN : RM101).
*
Series/Parallel operation with other model is not possible.
*
When units are operated with chassis and cover, derating is required.
RMC50A
Unit type
RMC 50A
-1
-
O
Ordering information
1
Series name
2
Output wattage
3
Output voltage combina-
tion
4
Optional
C :with Coating
G :Low leakage current
J :Connector type
N :with Cover
R
1
2
3
4
RMC