ChipFind - документация

Электронный компонент: PAA150F-15

Скачать:  PDF   ZIP

Document Outline

MODEL
PBA10F-5
PBA10F-12
PBA10F-24
MAX OUTPUT WATTAGE[W]
10
10.8
12
DC OUTPUT
5V 2A
12V 0.9A
24V 0.5A
SPECIFICATIONS
MODEL
PBA10F-5
PBA10F-12
PBA10F-24
INPUT
VOLTAGE[V]
AC85 - 264 1
f
or DC110 - 370 (AC50 or DC70 Please refer to the instruction manual 2.1 Input voltage
*
3)
CURRENT[A]
ACIN 100V 0.30typ (Io=100%)
ACIN 200V 0.20typ (Io=100%)
FREQUENCY[Hz]
50/60 (47 - 440) or DC
EFFICIENCY[%]
ACIN 100V 74typ
76typ
77typ
ACIN 200V 74typ
76typ
77typ
INRUSH CURRENT[A]
ACIN 100V 15typ (Io=100%)
ACIN 200V 30typ (Io=100%)
LEAKAGE CURRENT[mA]
0.15/0.30max (ACIN 100V/240V 60Hz, Io=100%, According to IEC60950-1,DENAN)
OUTPUT
VOLTAGE[V]
5
12
24
CURRENT[A]
2
0.9
0.5
LINE REGULATION[mV]
20max
48max
96max
LOAD REGULATION[mV]
40max
100max
150max
RIPPLE[mVp-p]
0 to +50
C
*
1
80max
120max
120max
-10 - 0
C
*
1
140max
160max
160max
RIPPLE NOISE[mVp-p]
0 to +50
C
*
1
120max
150max
150max
-10 - 0
C
*
1
160max
180max
180max
TEMPERATURE REGULATION[mV]
0 to +50
C
50max
120max
240max
-10 to +50
C
60max
150max
290max
DRIFT[mV]
*
2
20max
48max
96max
START-UP TIME[ms]
200typ(ACIN 100V, Io=100%)
*
Start-up time is 700ms typ for less than 1minute of applying input again from turning off the input voltage.
HOLD-UP TIME[ms]
20typ (ACIN 100V, Io=100%)
OUTPUT VOLTAGE ADJUSTMENT RANGE[V] 4.50 - 5.50
10.0 - 13.2
19.2 - 27.0
OUTPUT VOLTAGE SETTING[V]
5.00 - 5.15
12.00 - 12.48
24.00 - 24.96
PROTECTION
CIRCUIT AND
OTHERS
OVERCURRENT PROTECTION Works over 105% of rated current and recovers automatically
OVERVOLTAGE PROTECTION[V]
5.75 - 7.00
15.0 - 18.0
30.0 - 37.0
OPERATING INDICATION
LED (Green)
REMOTE ON/OFF
None
ISOLATION
INPUT-OUTPUT
AC3,000V 1minute, Cutoff current = 10mA, DC500V 50M
W
min (At Room Temperature)
INPUT-FG
AC2,000V 1minute, Cutoff current = 10mA, DC500V 50M
W
min (At Room Temperature)
OUTPUT-FG
AC500V 1minute, Cutoff current = 25mA, DC500V 50M
W
min (At Room Temperature)
ENVIRONMENT
OPERATING TEMP.,HUMID.AND ALTITUDE -10 to +71
C
(Required Derating), 20 - 90%RH (Non condensing) 3,000m (10,000feet) max
STORAGE TEMP.,HUMID.AND ALTITUDE -20 to +75
C
, 20 - 90%RH (Non condensing) 3,000m (10,000feet) max
VIBRATION
10 - 55Hz, 19.6m/s
2
(2G), 3minutes period, 60minutes each along X, Y and Z axis
IMPACT
196.1m/s
2
(20G), 11ms, once each X, Y and Z axis
SAFETY AND
NOISE
REGULATIONS
AGENCY APPROVALS (At only AC input) UL60950-1, C-UL(CSA60950-1), EN60950-1, EN50178 Complies with DEN-AN
CONDUCTED NOISE
Complies with FCC Part15 classB, VCCI-B, CISPR22-B, EN55011-B, EN55022-B
CE MARKING
Low Voltage Directive, EMC Directive
HARMONIC ATTENUATOR
Complies with IEC61000-3-2 (Not built-in to active filter
*
4)
OTHERS
CASE SIZE/WEIGHT
31
X
78
X
68mm (without terminal block) (W
X
H
X
D) / 150g max (without cover)
COOLING METHOD
Convection
*
1
Measured by 20MHz oscilloscope or Ripple-Noise meter(equivalent to KEISOKU-GIKEN
:RM101).
*
2
Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25
C
.
*
3 Derating is required.
*
4 When two or more units are used,they may not comply with the harmonic attenuator. Please
contact us for details.
*
Parallel operation with other model is not possible.
*
Derating is required when operated with cover.
*
A sound may occur from power supply at peak loading.
PBA10F
Unit type
PB
A
10
F
-
O
-
O
Ordering information
1
Series name
2
Single output
3
Output wattage
4
Universal input
5
Output voltage
6
Optional
C :with Coating
G :Low leakage current
E :Low leakage current
and EMI class A
T :Vertical terminal block
J :Connector type
N :with Cover
(UL508 is pending for approval)
N1 :with DIN rail
V :Output voltage setting
potentiometer external-
ly
R
1
2
3
4
5
6
PB
A-4
Recommended Noise Filter
NAC-06-472
High voltage pulse noise type : NAP series
Low leakage current type : NAM series
*The Noise Filter is recommended
*
to connect with several devices.
Cover is optional
2.5
Cover name plate
Cover (option)
Name plate
M3
Mounting hole
2-M3
Mounting hole
2-M3
AC(N)
AC(L)
FG
-V
+V
Terminal cover
Point A:C102
68
34.5
78
15.1
1.5
7.5
9.5
49.5
0.5
36
0.5
16.5
2
31
18
11
34.5
4
22.6
1.5
11.5
18
12.2
1.5
70.5
PBA10F
LED
Voltage adjust
Tolerance :
1
Mass : 150g or less (without cover)
PCB Material/thickness : CEM3 / 1.6mm
Chassis material : Electric galvanizing steel board
Dimensions in mm
Mounting torque : 0.6N
m(6.3kgf
cm)max
Screw tightening torque : M3 0.8N
m(8.5kgf
cm)max
Please connect safety ground to the unit in 2-M3 holes.
External size of option T,J,N,N1 and V is different from standard model and refer to 7 Option of instruction manual for details.
PB
A-5
PBA10F
Block diagram
2.5A
AC250V
NOISE
FILTER
INVERTER
CONTROL
CURRENT
SENSING
RECTIFIER
AND
FILTER
CONTROL
AC IN
DC OUT
FG
Photocoupler
Photocoupler
TRANSFORMER
85 - 264V
INRUSH
CURRENT
LIMIT
FUSE
OVER VOLTAGE
PROTECTION
RECTIFIER
AND
FILTER
External view
MODEL
PBA15F-3R3
PBA15F-5
PBA15F-9
PBA15F-12
PBA15F-15
PBA15F-24
PBA15F-48
MAX OUTPUT WATTAGE[W]
9.9
15
15.3
15.6
15
16.8
16.8
DC OUTPUT
3.3V 3A
5V 3A
9V 1.7A
12V 1.3A
15V 1A
24V 0.7A
48V 0.35A
SPECIFICATIONS
MODEL
PBA15F-3R3
PBA15F-5
PBA15F-9
PBA15F-12
PBA15F-15
PBA15F-24
PBA15F-48
INPUT
VOLTAGE[V]
AC85 - 264 1
f
or DC110 - 370 (AC50 or DC70 Please refer to the instruction manual 2.1 Input voltage
*
3)
CURRENT[A]
ACIN 100V 0.30typ (Io=100%) 0.4typ (Io=100%)
ACIN 200V 0.15typ (Io=100%) 0.2typ (Io=100%)
FREQUENCY[Hz]
50/60 (47 - 440) or DC
EFFICIENCY[%]
ACIN 100V 68typ
74typ
75typ
75typ
77typ
75typ
75typ
ACIN 200V 68typ
75typ
77typ
78typ
80typ
78typ
78typ
INRUSH CURRENT[A]
ACIN 100V 15typ (Io=100%) (At cold start)
ACIN 200V 30typ (Io=100%) (At cold start)
LEAKAGE CURRENT[mA]
0.15/0.30max (ACIN 100V/240V 60Hz, Io=100%, According to IEC60950-1,DENAN)
OUTPUT
VOLTAGE[V]
3.3
5
9
12
15
24
48
CURRENT[A]
3
3
1.7
1.3
1
0.7
0.35
LINE REGULATION[mV]
20max
20max
36max
48max
60max
96max
192max
LOAD REGULATION[mV]
40max
40max
100max
100max
120max
150max
240max
RIPPLE[mVp-p]
0 to +50
C
*
1
80max
80max
120max
120max
120max
120max
150max
-10 - 0
C
*
1
140max
140max
160max
160max
160max
160max
200max
RIPPLE NOISE[mVp-p]
0 to +50
C
*
1
120max
120max
150max
150max
150max
150max
250max
-10 - 0
C
*
1
160max
160max
180max
180max
180max
180max
300max
TEMPERATURE REGULATION[mV]
0 to +50
C
50max
50max
90max
120max
150max
240max
480max
-10 to +50
C
60max
60max
120max
150max
180max
290max
600max
DRIFT[mV]
*
2
20max
20max
36max
48max
60max
96max
192max
START-UP TIME[ms]
200typ(ACIN 100V, Io=100%)
*
Start-up time is 700ms typ for less than 1minute of applying input again from turning off the input voltage.
HOLD-UP TIME[ms]
20typ (ACIN 100V, Io=100%)
OUTPUT VOLTAGE ADJUSTMENT RANGE[V] 2.85 - 3.60
4.50 - 5.50
7.50 - 10.0
10.0 - 13.2
13.2 - 18.0
19.2 - 27.0
39.0 - 53.0
OUTPUT VOLTAGE SETTING[V]
3.30 - 3.40
5.00 - 5.15
9.00 - 9.36
12.00 - 12.48
15.00 - 15.60
24.00 - 24.96
48.00 - 49.92
PROTECTION
CIRCUIT AND
OTHERS
OVERCURRENT PROTECTION Works over 105% of rated current and recovers automatically
OVERVOLTAGE PROTECTION[V]
4.00 - 5.25
5.75 - 7.00
11.5 - 14.0
15.0 - 18.0
20.0 - 25.0
30.0 - 37.0
58.0 - 65.0
OPERATING INDICATION
LED (Green)
REMOTE ON/OFF
None
ISOLATION
INPUT-OUTPUT
AC3,000V 1minute, Cutoff current = 10mA, DC500V 50M
W
min (At Room Temperature)
INPUT-FG
AC2,000V 1minute, Cutoff current = 10mA, DC500V 50M
W
min (At Room Temperature)
OUTPUT-FG
AC500V 1minute, Cutoff current = 25mA, DC500V 50M
W
min (At Room Temperature)
ENVIRONMENT
OPERATING TEMP.,HUMID.AND ALTITUDE -10 to +71
C
(Required Derating), 20 - 90%RH (Non condensing) 3,000m (10,000feet) max
STORAGE TEMP.,HUMID.AND ALTITUDE -20 to +75
C
, 20 - 90%RH (Non condensing) 3,000m (10,000feet) max
VIBRATION
10 - 55Hz, 19.6m/s
2
(2G), 3minutes period, 60minutes each along X, Y and Z axis
IMPACT
196.1m/s
2
(20G), 11ms, once each X, Y and Z axis
SAFETY AND
NOISE
REGULATIONS
AGENCY APPROVALS (At only AC input) UL60950-1, C-UL(CSA60950-1), EN60950-1, EN50178 Complies with DEN-AN
CONDUCTED NOISE
Complies with FCC Part15 classB, VCCI-B, CISPR22-B, EN55011-B, EN55022-B
CE MARKING
Low Voltage Directive, EMC Directive
HARMONIC ATTENUATOR
Complies with IEC61000-3-2 (Not built-in to active filter
*
4)
OTHERS
CASE SIZE/WEIGHT
31
X
78
X
85mm (without terminal block) (W
X
H
X
D) / 200g max (without cover)
COOLING METHOD
Convection
*
1
Measured by 20MHz oscilloscope or Ripple-Noise meter(equivalent to KEISOKU-GIKEN
:RM101).
*
2
Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25
C
.
*
3 Derating is required.
*
4 When two or more units are used,they may not comply with the harmonic attenuator. Please
contact us for details.
*
Parallel operation with other model is not possible.
*
Derating is required when operated with cover.
*
A sound may occur from power supply at peak loading.
PBA15F
Unit type
PB
A
15
F
-
O
-
O
Ordering information
1
Series name
2
Single output
3
Output wattage
4
Universal input
5
Output voltage
6
Optional
C :with Coating
G :Low leakage current
E :Low leakage current
and EMI class A
T :Vertical terminal block
J :Connector type
N :with Cover
(UL508 is pending for approval)
N1 :with DIN rail
V :Output voltage setting
potentiometer external-
ly
R
1
2
3
4
5
6
PB
A-6
Recommended Noise Filter
NAC-06-472
High voltage pulse noise type : NAP series
Low leakage current type : NAM series
*The Noise Filter is recommended
*
to connect with several devices.
Cover is optional
2.5
Point A:C102
Cover (option)
Name plate
M3
Mounting hole
2-M3
Mounting hole
2-M3
AC(N)
AC(L)
FG
-V
+V
Terminal cover
15.1
1.5
5
18
31
34.5
34.5
78
36.5
11.5
85
16.5
2
70.5
12.2
1.5
18
22.6
1.5
31
0.5
60
0.5
9.5
7.5
PBA15F
PBW15F
LED
Voltage adjust
Cover name plate
Tolerance :
1
Mass : 200g or less (without cover)
PCB Material/thickness : CEM3 / 1.6mm
Chassis material : Electric galvanizing steel board
Dimensions in mm
Mounting torque : 0.6N
m(6.3kgf
cm)max
Screw tightening torque : M3 0.8N
m(8.5kgf
cm)max
Please connect safety ground to the unit in 2-M3 holes.
External size of option T,J,N,N1 and V is different from standard model and refer to 7 Option of instruction manual for details.
PB
A-7
PBA15F
Block diagram
2.5A
AC250V
AC IN
DC OUT
FG
85
- 264V
NOISE
FILTER
INVERTER
CONTROL
CURRENT
SENSING
RECTIFIER
AND
FILTER
CONTROL
Photocoupler
Photocoupler
TRANSFORMER
INRUSH
CURRENT
LIMIT
FUSE
OVER VOLTAGE
PROTECTION
RECTIFIER
AND
FILTER
External view
MODEL
PBA30F-3R3
PBA30F-5
PBA30F-9
PBA30F-12
PBA30F-15
PBA30F-24
PBA30F-48
MAX OUTPUT WATTAGE[W]
19.8
30
30.6
30
30
31.2
31.2
DC OUTPUT
3.3V 6A
5V 6A
9V 3.4A
12V 2.5A
15V 2A
24V 1.3A
48V 0.65A
SPECIFICATIONS
MODEL
PBA30F-3R3
PBA30F-5
PBA30F-9
PBA30F-12
PBA30F-15
PBA30F-24
PBA30F-48
INPUT
VOLTAGE[V]
AC85 - 264 1
f
or DC110 - 370 (AC50 or DC70 Please refer to the instruction manual 2.1 Input voltage
*
3)
CURRENT[A]
ACIN 100V 0.50typ (Io=100%) 0.70typ (Io=100%)
ACIN 200V 0.30typ (Io=100%) 0.40typ (Io=100%)
FREQUENCY[Hz]
50/60 (47 - 440) or DC
EFFICIENCY[%]
ACIN 100V 68typ
74typ
75typ
76typ
78typ
78typ
79typ
ACIN 200V 69typ
77typ
77typ
78typ
81typ
81typ
81typ
INRUSH CURRENT[A]
ACIN 100V 15typ (Io=100%) (At cold start)
ACIN 200V 30typ (Io=100%) (At cold start)
LEAKAGE CURRENT[mA]
0.30/0.65max (ACIN 100V/240V 60Hz, Io=100%, According to IEC60950-1,DENAN)
OUTPUT
VOLTAGE[V]
3.3
5
9
12
15
24
48
CURRENT[A]
6
6
3.4
2.5
2
1.3
0.65
LINE REGULATION[mV]
20max
20max
36max
48max
60max
96max
192max
LOAD REGULATION[mV]
40max
40max
100max
100max
120max
150max
240max
RIPPLE[mVp-p]
0 to +50
C
*
1
80max
80max
120max
120max
120max
120max
150max
-10 - 0
C
*
1
140max
140max
160max
160max
160max
160max
200max
RIPPLE NOISE[mVp-p]
0 to +50
C
*
1
120max
120max
150max
150max
150max
150max
250max
-10 - 0
C
*
1
160max
160max
180max
180max
180max
180max
300max
TEMPERATURE REGULATION[mV]
0 to +50
C
50max
50max
90max
120max
150max
240max
480max
-10 to +50
C
60max
60max
120max
150max
180max
290max
600max
DRIFT[mV]
*
2
20max
20max
36max
48max
60max
96max
192max
START-UP TIME[ms]
200typ(ACIN 100V, Io=100%)
*
Start-up time is 700ms typ for less than 1minute of applying input again from turning off the input voltage.
HOLD-UP TIME[ms]
20typ (ACIN 100V, Io=100%)
OUTPUT VOLTAGE ADJUSTMENT RANGE[V] 2.85 - 3.60
4.50 - 5.50
7.50 - 10.0
10.0 - 13.2
13.2 - 18.0
19.2 - 27.0
39.0 - 53.0
OUTPUT VOLTAGE SETTING[V]
3.30 - 3.40
5.00 - 5.15
9.00 - 9.36
12.00 - 12.48
15.00 - 15.60
24.00 - 24.96
48.00 - 49.92
PROTECTION
CIRCUIT AND
OTHERS
OVERCURRENT PROTECTION Works over 105% of rated current and recovers automatically
OVERVOLTAGE PROTECTION[V]
4.00 - 5.25
5.75 - 7.00
11.5 - 14.0
15.0 - 18.0
20.0 - 25.0
30.0 - 37.0
58.0 - 65.0
OPERATING INDICATION
LED (Green)
REMOTE ON/OFF
None
ISOLATION
INPUT-OUTPUT
AC3,000V 1minute, Cutoff current = 10mA, DC500V 50M
W
min (At Room Temperature)
INPUT-FG
AC2,000V 1minute, Cutoff current = 10mA, DC500V 50M
W
min (At Room Temperature)
OUTPUT-FG
AC500V 1minute, Cutoff current = 25mA, DC500V 50M
W
min (At Room Temperature)
ENVIRONMENT
OPERATING TEMP.,HUMID.AND ALTITUDE -10 to +71
C
(Required Derating), 20 - 90%RH (Non condensing) 3,000m (10,000feet) max
STORAGE TEMP.,HUMID.AND ALTITUDE -20 to +75
C
, 20 - 90%RH (Non condensing) 3,000m (10,000feet) max
VIBRATION
10 - 55Hz, 19.6m/s
2
(2G), 3minutes period, 60minutes each along X, Y and Z axis
IMPACT
196.1m/s
2
(20G), 11ms, once each X, Y and Z axis
SAFETY AND
NOISE
REGULATIONS
AGENCY APPROVALS (At only AC input) UL60950-1, C-UL(CSA60950-1), EN60950-1, EN50178 Complies with DEN-AN
CONDUCTED NOISE
Complies with FCC Part15 classB, VCCI-B, CISPR22-B, EN55011-B, EN55022-B
CE MARKING
Low Voltage Directive, EMC Directive
HARMONIC ATTENUATOR
Complies with IEC61000-3-2 (Not built-in to active filter
*
4)
OTHERS
CASE SIZE/WEIGHT
31
X
78
X
103mm (without terminal block) (W
X
H
X
D) / 270g max (without cover)
COOLING METHOD
Convection
*
1
Measured by 20MHz oscilloscope or Ripple-Noise meter(equivalent to KEISOKU-GIKEN
:RM101).
*
2
Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25
C
.
*
3 Derating is required.
*
4 When two or more units are used,they may not comply with the harmonic attenuator. Please
contact us for details.
*
Parallel operation with other model is not possible.
*
Derating is required when operated with cover.
*
A sound may occur from power supply at peak loading.
PBA30F
Unit type
PB
A
30
F
-
O
-
O
Ordering information
1
Series name
2
Single output
3
Output wattage
4
Universal input
5
Output voltage
6
Optional
C :with Coating
G :Low leakage current
E :Low leakage current
and EMI class A
T :Vertical terminal block
J :Connector type
N :with Cover
(UL508 is pending for approval)
N1 :with DIN rail
V :Output voltage setting
potentiometer external-
ly
R
1
2
3
4
5
6
PB
A-8
Recommended Noise Filter
NAC-06-472
High voltage pulse noise type : NAP series
Low leakage current type : NAM series
*The Noise Filter is recommended
*
to connect with several devices.
Cover is optional