ChipFind - документация

Электронный компонент: R100U-15

Скачать:  PDF   ZIP

Document Outline

MODEL
FCA50F-24
MAX OUTPUT WATTAGE[W]
50(Peak 160)
DC OUTPUT
24V 2.1(Peak 6.7)A
SPECIFICATIONS
MODEL
FCA50F-24
INPUT
VOLTAGE[V]
AC187 - 528 1
f
or DC265 - 746
CURRENT[A]
ACIN 240V 0.55typ
ACIN 480V 0.30typ
FREQUENCY[Hz]
50/60 (47 - 63)
EFFICIENCY[%]
ACIN 240V 82typ
ACIN 480V 78typ
INRUSH CURRENT[A]
ACIN 240V 25typ (At cold start) (At Room Temperature)
ACIN 480V 50typ (At cold start) (At Room Temperature)
LEAKAGE CURRENT[mA]
0.75max (60Hz, According to IEC60950)
OUTPUT
VOLTAGE[V]
24
CURRENT[A]
*
1
2.1 (Peak 6.7)
LINE REGULATION[mV]
96max
LOAD REGULATION[mV]
0 - 2.1A 150max
0 - 6.7A 480max
RIPPLE[mVp-p]
0 to +50
C
*
2
240max
-10 - 0
C
*
2
320max
RIPPLE NOISE[mVp-p]
0 to +50
C
*
2
680max
-10 - 0
C
*
2
720max
TEMPERATURE REGULATION[mV] -10 to +50
C
600max
DRIFT[mV]
*
5
100max
START-UP TIME[ms]
800max (ACIN 240V, Io=100%)
HOLD-UP TIME[ms]
10typ (ACIN 240V, Io=100%)
OUTPUT VOLTAGE ADJUSTMENT RANGE[V] 21.6 - 26.4
PROTECTION
CIRCUIT AND
OTHERS
OVERCURRENT PROTECTION Works over 105% of peak current and recovers automatically
OVERVOLTAGE PROTECTION
Works at 115 - 140% of rating
OPERATING INDICATION
LED (Green)
ISOLATION
INPUT-OUTPUT
AC3,000V 1minute, Cutoff current = 10mA, DC500V 50M
W
min (At Room Temperature)
INPUT-FG
AC2,000V 1minute, Cutoff current = 10mA, DC500V 50M
W
min (At Room Temperature)
OUTPUT-FG
AC500V 1minute, Cutoff current = 100mA, DC500V 50M
W
min (At Room Temperature)
ENVIRONMENT
OPERATING TEMP.,HUMID.AND ALTITUDE -10 to +70
C
, 20 - 90%RH (Non condensing) (Refer to DERATING CURVE), 3,000m (10,000feet) max
STORAGE TEMP.,HUMID.AND ALTITUDE -20 to +75
C
, 20 - 90%RH (Non condensing), 9,000m (30,000feet) max
VIBRATION
*
3
10 - 55Hz, 19.6m/s
2
(2G), 3minutes period, 60minutes each along X, Y and Z axis
IMPACT
*
3
196.1m/s
2
(20G), 11ms, once each X, Y and Z axis
SAFETY AND
NOISE
REGULATIONS
AGENCY APPROVALS
UL60950-1, C-UL, EN60950-1, EN50178
CONDUCTED NOISE
Complies with FCC-A, CISPR11-A, EN55011-A
OTHERS
CASE SIZE/WEIGHT
*
4
50
X
125
X
124mm (W
X
H
X
D) / 640g max
COOLING METHOD
Convection
*
1
Peak current for 150ms in a 30seconds period is acceptable.
*
2
In case of rated input/output(ACIN240-480v/2.1A), either the 20MHz oscilloscope or the ripple noise meter(equivalent to Keisokugiken:RM101) is used.
*
3
Option with DIN rail attachment(N1) is only for direction X(refer to sec4.2 in manual).
*
4
Depth of power supply is 132mm with DIN rail attachment.
*
5
Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25
C
, with the input voltage held constant at the rated input/output.
FCA50F
Unit type
FCA
50
F
-24
-
O
Ordering information
1
Series name
2
Output wattage
3
Universal input
4
Output voltage
5
Optional
N1 :with DIN rail attach-
ment
R
1
2
3
4
5
FCA
A-150
RISE TIME & FALL TIME
STATIC CHARACTERISTICS
OUTPUT V
O
L
T
A
GE
V
OUTPUT V
O
L
T
A
GE
V
RIPPLE
mVp-p
INPUT VOLTAGE
V 60Hz
INRUSH CURRENT
OVERCURRENT CHARACTERISTICS
OUTPUT CURRENT A
Io=100%
Ripple
Output Voltage
(AC 100V)
Io=100%
Io=50%
DC Output
AC Input
ACIN 480V
50ms/DIV
OUTPUT V
O
L
T
A
GE
V
50ms/DIV
20A/DIV
Input Voltage AC480V
60Hz
100%
Input voltage AC480V
Frequency
Load
150
160
170
180
190
200
210
220
230
240
250
24
22
20
18
16
14
12
10
8
25
50
75
100
25
20
15
10
5
0
26
24
22
20
18
16
14
12
2
4
6
8
10
12
FCA
A-151
FCA50F
External view
Terminal
Block
(M4)
+V
-V
FG
AC(L)
AC(N)
+
-
FG
AC(L)
AC(N)
FCA50F-24
(22)
(12)
(7)
(116
)
(72
)
(35.5
)
(8)
(110
)
(102
)
(34
)
(24.5)
(15.5)
(11.5)
13max
13
10
124
125
LED
Voltage Adjust
7
16
50
30
Spacer
FCA50F-24-N1 only
FCA50F-24-N1 only
DIN Rail Attachment
71.1
0.5
25.4
0.5
45.9
18max
50
44.5
25.4
Terminal Block Cover
119
3.8
3-M3 Mounting Hole
12.7
Weight : 640g or less
Tolerance :
1
Mounting torque : 0.6N
m
(6.3kgf
cm)max
Dimensions in mm.
Performance data
MODEL
FCA75F-24
MAX OUTPUT WATTAGE[W]
75(Peak 240)
DC OUTPUT
24V 3.1(Peak 10)A
SPECIFICATIONS
MODEL
FCA75F-24
INPUT
VOLTAGE[V]
AC187 - 528 1
f
or DC265 - 746
CURRENT[A]
ACIN 240V 0.80typ
ACIN 480V 0.45typ
FREQUENCY[Hz]
50/60 (47 - 63)
EFFICIENCY[%]
ACIN 240V 82typ
ACIN 480V 78typ
INRUSH CURRENT[A]
ACIN 240V 25typ (At cold start) (At Room Temperature)
ACIN 480V 50typ (At cold start) (At Room Temperature)
LEAKAGE CURRENT[mA]
0.75max (60Hz, According to IEC60950)
OUTPUT
VOLTAGE[V]
24
CURRENT[A]
*
1
3.1 (Peak 10)
LINE REGULATION[mV]
96max
LOAD REGULATION[mV]
0 - 3.1A 150max
0 - 10A 480max
RIPPLE[mVp-p]
0 to +50
C
*
2
240max
-10 - 0
C
*
2
320max
RIPPLE NOISE[mVp-p]
0 to +50
C
*
2
680max
-10 - 0
C
*
2
720max
TEMPERATURE REGULATION[mV] -10 to +50
C
600max
DRIFT[mV]
*
5
100max
START-UP TIME[ms]
800max (ACIN 240V, Io=100%)
HOLD-UP TIME[ms]
10typ (ACIN 240V, Io=100%)
OUTPUT VOLTAGE ADJUSTMENT RANGE[V] 21.6 - 26.4
PROTECTION
CIRCUIT AND
OTHERS
OVERCURRENT PROTECTION Works over 105% of peak current and recovers automatically
OVERVOLTAGE PROTECTION
Works at 115 - 140% of rating
OPERATING INDICATION
LED (Green)
ISOLATION
INPUT-OUTPUT
AC3,000V 1minute, Cutoff current = 10mA, DC500V 50M
W
min (At Room Temperature)
INPUT-FG
AC2,000V 1minute, Cutoff current = 10mA, DC500V 50M
W
min (At Room Temperature)
OUTPUT-FG
AC500V 1minute, Cutoff current = 100mA, DC500V 50M
W
min (At Room Temperature)
ENVIRONMENT
OPERATING TEMP.,HUMID.AND ALTITUDE -10 to +70
C
, 20 - 90%RH (Non condensing) (Refer to DERATING CURVE), 3,000m (10,000feet) max
STORAGE TEMP.,HUMID.AND ALTITUDE -20 to +75
C
, 20 - 90%RH (Non condensing), 9,000m (30,000feet) max
VIBRATION
*
3
10 - 55Hz, 19.6m/s
2
(2G), 3minutes period, 60minutes each along X, Y and Z axis
IMPACT
*
3
196.1m/s
2
(20G), 11ms, once each X, Y and Z axis
SAFETY AND
NOISE
REGULATIONS
AGENCY APPROVALS
UL60950-1, C-UL, EN60950-1, EN50178
CONDUCTED NOISE
Complies with FCC-A, CISPR11-A, EN55011-A
OTHERS
CASE SIZE/WEIGHT
*
4
65
X
125
X
124mm (W
X
H
X
D) / 750g max
COOLING METHOD
Convection
*
1
Peak current for 150ms in a 30seconds period is acceptable.
*
2
In case of rated input/output(ACIN240-480v/3.1A), either the 20MHz oscilloscope or the ripple noise meter(equivalent to Keisokugiken:RM101) is used.
*
3
Option with DIN rail attachment(N1) is only for direction X(refer to sec4.2 in manual).
*
4
Depth of power supply is 132mm with DIN rail attachment.
*
5
Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25
C
, with the input voltage held constant at the rated input/output.
FCA75F
Unit type
FCA
75
F
-24
-
O
Ordering information
1
Series name
2
Output wattage
3
Universal input
4
Output voltage
5
Optional
N1 :with DIN rail attach-
ment
R
1
2
3
4
5
FCA
A-152
RISE TIME & FALL TIME
STATIC CHARACTERISTICS
OUTPUT V
O
L
T
A
GE
V
OUTPUT V
O
L
T
A
GE
V
RIPPLE
mVp-p
INPUT VOLTAGE
V 60Hz
INRUSH CURRENT
OVERCURRENT CHARACTERISTICS
OUTPUT CURRENT A
Io=100%
Ripple
Output Voltage
(AC 200V)
Io=100%
Io=50%
DC Output
AC Input
ACIN 480V
50ms/DIV
OUTPUT V
O
L
T
A
GE
V
50ms/DIV
20A/DIV
Input Voltage AC480V
60Hz
100%
Input voltage AC480V
Frequency
Load
150
160
170
180
190
200
210
220
230
240
250
24
22
20
18
16
14
12
10
8
25
50
75
100
25
20
15
10
5
0
26
24
22
20
18
16
14
12
2
4
6
8
10
12
FCA
A-153
FCA75F
External view
Terminal
Block
(M4)
+V
-V
FG
AC(L)
AC(N)
+
-
FG
AC(L)
AC(N)
FCA75F-24
(37)
(12)
(7)
(116
)
(72
)
(35.5
)
(8)
(110
)
(102
)
(34
)
(24.5)
(15.5)
(11.5)
13max
13
10
124
125
LED
Voltage Adjust
7
18
65
45
Spacer
FCA75F-24-N1
only
FCA75F-24-N1
only
DIN Rail
Attachment
71.1
0.5
38.1
0.5
45.9
18max
64.5
59.5
31.75
Terminal Block Cover
119
3.8
3-M3 Mounting Hole
12.7
Weight : 750g or less
Tolerance :
1
Mounting torque : 0.6N
m
(6.3kgf
cm)max
Dimensions in mm.
Performance data
MODEL
FCA200F-24
MAX OUTPUT WATTAGE[W]
200 (Peak 1,008)
DC OUTPUT
24V 8.4 (Peak 42)A
SPECIFICATIONS
MODEL
FCA200F-24
INPUT
VOLTAGE[V]
AC187 - 528 1
f
or DC265 - 530
CURRENT[A]
ACIN 240V 1.10typ
ACIN 480V 0.55typ
FREQUENCY[Hz]
50/60 (47 - 63)
EFFICIENCY[%]
ACIN 240V 81typ
ACIN 480V 81typ
POWER FACTOR
ACIN 240V 0.98typ
ACIN 480V 0.93typ
INRUSH CURRENT[A]
ACIN 240V 25typ (At cold start) (At Room Temperature)
ACIN 480V 50typ (At cold start) (At Room Temperature)
LEAKAGE CURRENT[mA]
1.5max (60Hz, According to IEC60950)
OUTPUT
VOLTAGE[V]
24
CURRENT[A]
*
1
8.4 (Peak 42)
LINE REGULATION[mV]
96max
LOAD REGULATION[mV] 0 - 8.4A 150max
RIPPLE[mVp-p]
0 to +50
C
*
2
240max
-10 - 0
C
*
2
320max
RIPPLE NOISE[mVp-p]
0 to +50
C
*
2
680max
-10 - 0
C
*
2
720max
TEMPERATURE REGULATION[mV] -10 to +50
C
600max
DRIFT[mV]
*
5
100max
START-UP TIME[ms]
800max (ACIN 240V, Io=100%)
HOLD-UP TIME[ms]
100typ (ACIN 240V, Io=100%)
OUTPUT VOLTAGE ADJUSTMENT RANGE[V] 21.6 - 26.4
PROTECTION
CIRCUIT AND
OTHERS
OVERCURRENT PROTECTION Works over 105% of peak current and recovers automatically
OVERVOLTAGE PROTECTION
Works at 115 - 140% of rating
OPERATING INDICATION
LED (Green)
ISOLATION
INPUT-OUTPUT
AC3,000V 1minute, Cutoff current = 10mA, DC500V 50M
W
min (At Room Temperature)
INPUT-FG
AC2,000V 1minute, Cutoff current = 10mA, DC500V 50M
W
min (At Room Temperature)
OUTPUT-FG
AC500V 1minute, Cutoff current = 100mA, DC500V 50M
W
min (At Room Temperature)
ENVIRONMENT
OPERATING TEMP.,HUMID.AND ALTITUDE -10 to +60
C
, 20 - 90%RH (Non condensing) (Refer to DERATING CURVE), 3,000m (10,000feet) max
STORAGE TEMP.,HUMID.AND ALTITUDE -20 to +75
C
, 20 - 90%RH (Non condensing), 9,000m (30,000feet) max
VIBRATION
*
3
10 - 55Hz, 19.6m/s
2
(2G), 3minutes period, 60minutes each along X, Y and Z axis
IMPACT
*
3
196.1m/s
2
(20G), 11ms, once each X, Y and Z axis
SAFETY AND
NOISE
REGULATIONS
AGENCY APPROVALS
UL60950-1, C-UL, EN60950-1
CONDUCTED NOISE
Complies with FCC-A, CISPR11-A, EN55011-A
OTHERS
CASE SIZE/WEIGHT
*
4
150
X
125
X
125mm (W
X
H
X
D) / 1,700g max
COOLING METHOD
Convection
*
1
Peak current for 50ms in a 30seconds period is acceptable.
*
2
In case of rated input/output(ACIN240-480v/8.4A), either the 20MHz oscilloscope or the ripple noise meter(equivalent to Keisokugiken:RM101) is used.
*
3
Option with DIN rail attachment(N1) is only for direction X(refer to sec4.2 in manual).
*
4
Depth of power supply is 133mm with DIN rail attachment.
*
5
Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25
C
, with the input voltage held constant at the rated input/output.
FCA200F
Unit type
FCA 200
F
-24
-
O
Ordering information
1
Series name
2
Output wattage
3
Universal input
4
Output voltage
5
Optional
N1:with DIN rail attach-
ment
R
1
2
3
4
5
FCA
A-154
RoHS : Please consult us for details