M O D E L N U M B E R S
7PCV2415
7PCV2425
10PCV2415 10PCV2425 10PCV2450 10PCV2475 10PCV2490
OUTPUT SPECIFICATIONS
Operating Voltage (47-63 Hz) [Vrms]
100-240
100-240
100-240
100-240
100-240
Max. Load Current Range [Arms]
.15-15
.15-25
.15-50
.15-75
.15-90
Transient Overvoltage [Vpk]
600
600
600
600
600
Max. Surge Current, (1 Cycle) [Apk]
150
250
625
1000
1200
Max. Off-State Leakage Current @ Rated Voltage [mA]
10
15
20
20
20
Maximum I 2 t for Fusing (8.3 msec) [A 2sec]
94
260
1620
4150
6000
Maximum Voltage Drop (100% On) [Vpk]
1.6
1.6
1.6
1.6
1.6
Minimum Off-State dv/dt [V/sec]
200
200
200
200
200
Power Factor (Min.) with Max. Load
0.5
0.5
0.5
0.5
0.5
INPUT SPECIFICATIONS
7PCV24xx
10PCV24xx
Control Voltage Range
2-7 Vdc
2-10 Vdc
Typical Input Current @ 5 Vdc
4 mA
4 mA
GENERAL NOTES
All parameters at 25 C unless otherwise specified.
Operates at 60Hz & 50Hz
Internal Snubber
Industry Standard Package
Control Circuit Requires No
Adjustment or Calibration
FastFax Document No. 204
SERIES PCV.
Rev. 041902
PAGE 1 OF 2
The PCV Series proportional controllers
are self contained power control mod-
ules integrating a complete phase fired
logic control system and a solid state
relay in the same standard package.
Typical applications include heaters,
vibratory feeders and tungsten lamps.
Series PCV
Analog Input Power Controller
TYPICAL APPLICATIONS
Industrial Temperature Controllers
Light Dimming
Vibratory Feeders
Resistive Heating Elements
Conveyor Speed Control
UNSUITABLE APPLICATIONS
The PCV is not suitable for some load applications
including, but not limited to the following:
AC Motor Control
Three Phase Motors
Transformers requiring pure sine wave input
Zero Crossing Applications
Please contact Crydom's application
engineering department for additional
information and specific application
questions.
100
80
60
40
20
0
2.5
4.5
5.5
3.5
6.5
7.5
8.5
9.5
Input Voltage
Percentage ON
Percentage On vs. Input Voltage
50 Hz
60 Hz
50 Hz
60 Hz
50 Hz
60 Hz
50 Hz
60 Hz
50 Hz
60 Hz
50 Hz
60 Hz
50 Hz
60 Hz
50 Hz
60 Hz
2002 CRYDOM CORP, Specifications subject to change without notice.
For recommended applications and more information contact:
USA: Sales Support (877) 502-5500 Tech Support (877) 702-7700 FAX (619) 710-8540
Crydom Corp, 2320 Paseo de las Americas, Ste. 201, San Diego, CA 92154
Email: sales@crydom.com WEB SITE: http://www.crydom.com
UK: +44 (0)1202 365070 FAX +44 (0)1202 365090 Crydom International Ltd., 7 Cobham
Road, Ferndown Industrial Estate, Ferndown, Dorset BH21 7PE, Email: intsales@crydom.com.
GERMANY: +49 (0)180 3000 506
1.87
(47.5)
.78
(19.8)
2.30
(58.4)
1.70
(43.2)
.90
(22.9)
.45
(11.4)
1.10
(27.9)
8-32 TERMINAL
(2 PLACES )
1.00
(25.4)
6-32 TERMINAL
(2 PLACES)
1.80
(45.7)
SOLID-STATE RELAY
1
2
OUTPUT
3
4
+
--
INPUT
MOUNTING
HOLE/SLOT
0.17 (4.3) DIA.
BASE PLATE
.125 (3.2)
GENERAL SPECIFICATIONS
Dielectric Strength, Signal to Load
2500 Vrms
Dielectric Strength, Signal to Base
2500 Vrms
Ambient Operating Temperature Range
-30 to 80C
Ambient Storage Temperature Range
-40 to 125C
M ECHANICAL SPECIFICATIONS
Weight: (typical)
3.5 oz. (100g)
Encapsulation:
Thermally Conductive Epoxy
Terminals:
Screws and Saddle Clamps Furnished, Unmounted
Series PCV
Analog Input Power Controller
30
20
10
25
15
5
0
5
10
20
25
15
20
40
60
80
Load Current [Arms]
Max Ambient Temp. [C]
Power Dissipation
95
120
Base Plate Temp [
C]
25A
1C/W
100
110
3C/W
NO HEATSINK
60
40
20
0
10
20
40
50
30
20
40
60
80
Load Current [Arms]
Max Ambient Temp. [C]
Power Dissipation
90
Base Plate Temp [
C]
50A
2C/W
1C/W
.5C/W
100
110
120
1.5C/W
NO HEATSINK
90
60
30
0
15
30
60
75
45
20
40
60
80
Load Current [Arms]
Max Ambient Temp. [C]
Power Dissipation
100
110
120
Base Plate Temp [
C]
75A
.5C/W
95
1C/W
120
80
40
0
20
40
80
0
60
20
40
60
80
Load Current [Arms]
Max Ambient Temp. [C]
Power Dissipation
100
110
120
Base Plate Temp [
C]
90A
1C/W
.4C/W
.2C/W
90
.5C/W
2C/W
.3C/W
15
10
5
0
3
6
12
15
9
20
40
60
80
Load Current [Arms]
Max Ambient Temp. [C]
Power Dissipation
Base Plate Temp [
C]
15A
4C/W
2C/W
6C/W
NO HEATSINK
112
124
116
120
CURRENT DERATING CURVES
FastFax Document No. 204
SERIES PCV.
Rev. 041902
PAGE 2 OF 2
All dimensions are in inches (millimeters)
Screw Torque Requirements:
6-32 Screws - 10 in. lbs.,
8-32 and 10-32 Screws - 20in. lbs.
(Screws dry without grease.)
PROPORTIONAL
CONTROLLER
1
2
4
3
~
INPUT
OUTPUT
+
--
W IRING DIAGRAM
2002 CRYDOM CORP, Specifications subject to change without notice.
For recommended applications and more information contact:
USA: Sales Support (877) 502-5500 Tech Support (877) 702-7700 FAX (619) 710-8540
Crydom Corp, 2320 Paseo de las Americas, Ste. 201, San Diego, CA 92154
Email: sales@crydom.com WEB SITE: http://www.crydom.com
UK: +44 (0)1202 365070 FAX +44 (0)1202 365090 Crydom International Ltd., 7 Cobham
Road, Ferndown Industrial Estate, Ferndown, Dorset BH21 7PE, Email: intsales@crydom.com.
GERMANY: +49 (0)180 3000 506