ChipFind - документация

Электронный компонент: 20LPCV2415

Скачать:  PDF   ZIP
0-5 Vdc CONTROL
5LPCV2415
5LPCV2425
5LPCV2440
5LPCV2475
5LPCV24110
M O D E L N U M B E R S
0-10 Vdc CONTROL
10LPCV2415
10LPCV2425
10LPCV2440
10LPCV2475 10LPCV24110
4-20 mA CONTROL
20LPCV2415
20LPCV2425
20LPCV2440
20LPCV2475 20LPCV24110
OUTPUT SPECIFICATIONS
Operating Voltage (60 Hz) [Vrms]
20-300
20-300
20-300
20-300
20-300
Load Current Range
[Arms]
.10-15 .10-25
.10-40
.15-75
.20-110
Max. Surge Current, (16.6ms) [Apk]
150
250
625
1000
1500
Max. Off-State Leakage Current @ Rated Voltage [mArms]
10
15
20
30
50
Thermal Resistance Junction to Case (R
JC) [C/W]
1.48
1.02
0.63
0.31
0.28
Maximum I2 t for Fusing, (8.3 msec.) [A2sec]
94
260
1620
4150
9340
Maximum Voltage Drop (100% On) [Vpk]
1.6
1.6
1.6
1.6
1.6
Minmum Off-State dv/dt [V/sec]
200
200
200
200
200
Power Factor (Min.) with Max. Load
0.5
0.5
0.5
0.5
0.5
INPUT SPECIFICATIONS
Control Range (Nominal)
0-5 Vdc
0-10 Vdc
4-20 mA
Control Range Limits (Min/Msx)
-0.5/10 Vdc
-1.0/20 Vdc
-0.5/25 mA
Turn-On Threshold
.25 Vdc
0.5 Vdc
4.5 mA
Min. Input Impedance
12.7K Ohms
25K Ohms
460 Ohms
GENERAL NOTES
All parameters at 25C unless otherwise specified.
Linear taper potentiometer 1-10K Ohm, 1/2 Watt.
50Hz models available.
20Vac must be in phase with load.
Precise Proportional Load
Control
Optically Isolated
0-5 Vdc, 0-10 Vdc, 4-20mA
Input Control M odels
Control Circuit Requires no
Adjustment or Calibration
FastFax Document No. 207
SERIES LPCV.
Rev. 040802
PAGE 1 OF 3
The LPCV Linear Proportional
Controllers control loads up 110
Amps. Changes in the input signal
linearly vary the firing angle of the
thyristor load control device. Control
circuitry and power switch are in the
same package. The PS-120 (120V)
and PS-240 (240V) power supplies are
designed for use with the LPCV con-
troller to provide the 20Vac required
in addition to the control voltage.
Series LPCV
Linear Proportional Load Controller
TYPICAL APPLICATIONS
Infrared and Quartz Heaters
Resistive Heating Elements
Transformers
Rectified DC Motors
Thermal Forming Equipment
Blow Molding Equipment
Industrial Temperature Controllers
Conveyor Speed Control
Printing Applications
10V
(20 mA)
(4 mA)
7.5V
5V
2.5V
0V
5V
2.5V
0V
180
135
45
0
90
Firing Angle vs. Input Signal
2002 CRYDOM CORP, Specifications subject to change without notice.
Transient Overvoltage [Vpk]
600
600
600
600
600
y
For recommended applications and more information contact:
USA: Sales Support (877) 502-5500 Tech Support (877) 702-7700 FAX (619) 710-8540
Crydom Corp, 2320 Paseo de las Americas, Ste. 201, San Diego, CA 92154
Email: sales@crydom.com WEB SITE: http://www.crydom.com
UK: +44 (0)1202 365070 FAX +44 (0)1202 365090 Crydom International Ltd., 7 Cobham
Road, Ferndown Industrial Estate, Ferndown, Dorset BH21 7PE, Email: intsales@crydom.com.
GERMANY: +49 (0)180 3000 506
GENERAL SPECIFICATIONS
Dielectric Strength, Signal to Load
2500 Vrms
Dielectric Strength, Signal to Base
2500 Vrms
Ambient Operating Temperature Range
-30 to 80C
Ambient Storage Temperature Range
-40 to 125C
M ECHANICAL SPECIFICATIONS
Weight: (typical)
6.0 oz. (175g)
Encapsulation:
Thermally Conductive Epoxy
Terminals:
8-32 Screws, .25 Inch Fastons
POW ER SUPPLY SPECIFICATIONS
PS120
PS240
Input Voltage 50/60Hz
120 Vac
240 Vac
Output Voltage 50/60Hz
20 Vac/100mA
20 Vac/100mA
Ambient Operating Temperature Range
-30 to 80C
Ambient Storage Temperature Range
-40 to 125C
M ECHANICAL SPECIFICATIONS
Weight: (typical)
8.6 oz. (245g)
Encapsulation:
Thermally Conductive Epoxy
Terminals:
6-32 Screws, .25 Inch Fastons
NOTE: UNSUITABLE APPLICATIONS
The LPCV is not suitable for some load control applications including, but not lim-
ited to the following:
AC Motor Control
Three Phase Motors
Tranformers requiring pure sine wave input
Applications which cannot withstand thyristor noise
Zero Crossing Applications
Please contact Crydom's application engineering department for additional infor-
mation and specific application questions.
2.00
(50.8)
2.25
(57.2)
1.00
(25.4)
2.50
(63.5)
1.00
(25.4)
2.10
(53.3)
2.21
(56.1)
2.21
(56.1)
2.62
(66.5)
1.05
(26.7)
1.52
(38.6)
1.35 Max.
(40.6)
.30 Typ.
(7.6)
.62
(15.7)
.12
(3.0)
1.60 Max.
(40.6)
PROPORTIONAL CONTROLLER
OUTPUT
8-32 TERMINALS
(2 PLACES)
MOUNTING SLOT
0.17 (4.3) DIA.
.12
(3.0)
6-32 TERMINALS
(2 PLACES)
.250 FASTON
TERMINALS
(5 PLACES)
.250 FASTON
TERMINALS
(2 PLACES)
PS120/ PS240
INPUT
OUTPUT
W IRING DIAGRAM
PROPORTIONAL CONTROLLER
OUTPUT
1
2
7 6
5 4 3
From Control
0-5 Vdc
0-10 Vdc
4-20 mA
12Vdc Output
For Manual Control
Note: Not Used
if Connected to
Analog Card
20 Vac from Power
Supply Module
PS-120 (120Vac)
PS-240 (240Vac)
5
4
3
+
--
~
FastFax Document No. 207
SERIES LPCV.
Rev. 040802
PAGE 2 OF 3
Series LPCV
Linear Proportional Load Controller
All dimensions are in inches
(millimeters)
Screw Torque Requirements:
6-32 Screws - 10 in./lbs.,
8-32 and 10-32 Screws - 20in./lbs.
(Screws dry without grease.)
2002 CRYDOM CORP, Specifications subject to change without notice.
See note
For recommended applications and more information contact:
USA: Sales Support (877) 502-5500 Tech Support (877) 702-7700 FAX (619) 710-8540
Crydom Corp, 2320 Paseo de las Americas, Ste. 201, San Diego, CA 92154
Email: sales@crydom.com WEB SITE: http://www.crydom.com
UK: +44 (0)1202 365070 FAX +44 (0)1202 365090 Crydom International Ltd., 7 Cobham
Road, Ferndown Industrial Estate, Ferndown, Dorset BH21 7PE, Email: intsales@crydom.com.
GERMANY: +49 (0)180 3000 506
100
80
60
40
20
0
1
2
3
4
5
Input Voltage
Percentage ON
0-5 Vdc Control
50 Hz
60 Hz
100
80
60
40
20
0
2
4
8
10
6
12
14
16
18
20
Input Voltage
Percentage ON
22
4-20 mA Control
50 Hz
60 Hz
100
80
60
40
20
0
1
2
4
5
3
6
7
8
9
10
Input Voltage
Percentage ON
0-10 Vdc Control
50 Hz
60 Hz
P E R C E N T A G E O N v s . I N P U T V O L T A G E
15
10
5
0
3
6
12
15
9
20
40
60
80
Load Current [Arms]
Max Ambient Temp. [C]
Po
wer Dissipation
Base Plate Temp [

C]
15A
30
20
10
25
15
5
0
5
10
20
25
15
20
40
60
80
Load Current [Arms]
Max Ambient Temp. [C]
Power Dissipation
95
120
Base Plate Temp [

C]
25A
1C/W
100
110
3C/W
NO HEATSINK
60
40
20
0
10
20
40
30
20
40
60
80
Load Current [Arms]
Max Ambient Temp. [C]
Power Dissipation
90
Base Plate Temp [

C]
40A
2C/W
1C/W .5C/W
100
110
120
1.5C/W
NO HEATSINK
120
80
40
0
20
40
80
0
60
20
40
60
80
Load Current [Arms]
Max Ambient Temp. [C]
Power Dissipation
100
110
120
Base Plate Temp [

C]
75A
.5C/W
95
1C/W
2C/W
.3C/W
160
80
40
120
0
30
60
120
0
90
20
40
60
80
Load Current [Arms]
Max Ambient Temp. [C]
Power Dissipation
100
110
120
Base Plate Temp [

C]
110A
.5C/W
.4C/W
90
1C/W
.2C/W
4C/W
2C/W
6C/W
NO HEATSINK
112
124
116
120
CURRENT DERATING CURVES
FastFax Document No. 207
SERIES LPCV.
Rev. 040802
PAGE 3 OF 3
Series LPCV
Linear Proportional Load Controller
2002 CRYDOM CORP, Specifications subject to change without notice.
For recommended applications and more information contact:
USA: Sales Support (877) 502-5500 Tech Support (877) 702-7700 FAX (619) 710-8540
Crydom Corp, 2320 Paseo de las Americas, Ste. 201, San Diego, CA 92154
Email: sales@crydom.com WEB SITE: http://www.crydom.com
UK: +44 (0)1202 365070 FAX +44 (0)1202 365090 Crydom International Ltd., 7 Cobham
Road, Ferndown Industrial Estate, Ferndown, Dorset BH21 7PE, Email: intsales@crydom.com.
GERMANY: +49 (0)180 3000 506