ChipFind - документация

Электронный компонент: H12D4840DE-10

Скачать:  PDF   ZIP
M O D E L N U M B E R S
D2425D
D2440D
H12D4825D
H12D4840D
OUTPUT SPECIFICATIONS
Operating Voltage (47-63 Hz) [Vrms]
24-280
24-280
48-530
48-530
Load Current Range
[Arms]
.15-25
.15-40
.15-25
.15-40
Transient Overvoltage [Vpk]
600
600
1200
1200
Max. Surge Current, (16.6ms) [Apk]
250
625
250
625
Max. On-State Voltage Drop @ Rated Current [Vpk]
1.6
1.6
1.6
1.6
Thermal Resistance Junction to Case (R
JC) [C/W]
1.02
.63
1.02
.63
Maximum I2 t for Fusing, (8.3 msec.) [A2sec]
260
1620
260
1620
Max. Off-State Leakage Current @ Rated Voltage [mArms]
10
10
10
10
Min. Off-State dv/dt @ Max. Rated Voltage [V/sec]
500
500
500
500
Max. Turn-On Time
1/2 cycle
1/2 cycle
1/2 cycle
1/2 cycle
Max. Turn-Off Time
1/2 cycle
1/2 cycle
1/2 cycle
1/2 cycle
Power Factor (Min.) with Max. Load
0.5
0.5
0.5
0.5
INPUT SPECIFICATIONS
H12D48XXD
Control Voltage Range
4-15Vdc
Max. Turn-On Voltage
4.0 Vdc
Min. Turn-Off Voltage
1.0 Vdc
Nominal Input Impedance
240 Ohms
Typical Input Current @ 5Vdc (@ 24Vdc for E-Suffix)
13mA
GENERAL NOTES
All parameters at 25C and per section unless otherwise specified.
Off-State dv/dt test method per EIA/NARM standard RS-443, paragraph 13.11.1
Heat sinking required, for derating curves see page 2.
Turn-on time for random turn-on (-10) versions is 0.1 msec.
Zero Voltage and Random
Turn-On Swi tching
SCR Output
Industry Standard Package
Panel M ount
FastFax Document No. 165
DUAL.
Rev. 021302
PAGE 1 OF 2
Two totally independent AC output
relays come in a single standard panel-
mount package. Utilizing an AC switch
output with internal snubber, relays
provide greater protection against false
triggering. Model choices include zero-
voltage or random turn-on (phase con-
trollable) switching.
Manufactured in Crydom's ISO 9001
Certified facility for optimum product
performance and reliability.
Dual Relays
25-40Amp 120/240, 480 Vac AC Output
Crydom Heat Sinks
offer excellent thermal
management and are perfectly matched to the
load current ratings of Crydom panel mount
relays. Request Crydom's Heat Sink specifica-
tion sheet for all the details.
2002 CRYDOM CORP, Specifications subject to change without notice.
D2425DE
D2440DE
H12D4825DE
H12D4840DE
E-SUFFIX
15-32Vdc
15 Vdc
1.0 Vdc
1500 Ohms
15mA
D24XXD
4-15Vdc
4.0 Vdc
1.0 Vdc
300 Ohms
13mA
For recommended applications and more information contact:
USA: Sales Support (877) 502-5500 Tech Support (877) 702-7700 FAX (619) 710-8540
Crydom Corp, 2320 Paseo de las Americas, Ste. 201, San Diego, CA 92154
Email: sales@crydom.com WEB SITE: http://www.crydom.com
UK: +44 (0)1202 365070 FAX +44 (0)1202 365090 Crydom International Ltd., 7 Cobham
Road, Ferndown Industrial Estate, Ferndown, Dorset BH21 7PE, Email: intsales@crydom.com.
GERMANY: +49 (0)180 3000 506
All dimensions are in inches (millimeters)
CURRENT DERATING CURVES
120/240 V MO DEL
480V MO DEL
AVAILABLE OPTIONS
-10
Random Turn-On,
Phase Controllable
GENERAL SPECIFICATIONS
Dielectric Strength50/60Hz Input/Output/Base
4000 Vrms
Insulation Resistance (Min.) @ 500 Vdc
10
9
Ohm
Max. Capacitance Input/Output
10 pF
Ambient Operating Temperature Range
-40 to 80C
Ambient Storage Temperature Range
-40 to 125C
M ECHANICAL SPECIFICATIONS
Weight: (typical)
3.0 oz. (86.5g)
Encapsulation: Thermally
Conductive
Epoxy
Terminals:
.25' Fastons, .025' Square Pins
APPROVALS
UL
E116949
CSA LR81689 (240V only)
VDE 5902 UG
FastFax Document No. 165
DUAL.
Rev. 021302
PAGE 2 OF 2
Dual Relays
25-40Amp 120/240, 480 Vac AC Output
2002 CRYDOM CORP, Specifications subject to change without notice.
E
15-32Vdc Control
Example:
H12D4840DE
1.87
(47.5)
.85
(21.6)
1.31
(33.2)
1.00
(25.4)
1.17
(29.7)
FASTON
TERMINAL
.250 X .032
(4 PLACES)
PIN .025 SQ.
.100 CENTERS
4 PLACES
MOUNTING
HOLE/SLOT
0.17 (4.3) DIA.
DUAL SOLID STATE RELAY
DUAL SOLID STATE RELAY
4-15VDC
CONTROL
B
CONTROL
A
4-15VDC
CONTROL
B
CONTROL
A
A1
A2
B1
B2
120/24OV - 20A
120/24OV - 20A
.85
(21.6)
1.31
(33.2)
.15
(3.8)
.50
(12.7)
.45
(11.4)
.55
(14.0)
2.30
(58.4)
1.80
(45.7)
.77
(19.6)
1.37
(34.8)
1.87
(47.5)
1.60
(40.6)
MOUNTING HOLE/SLOT
.017 (4.3) DIA.
2 PLC'S
A1 A2
120/24OV - 20A
120/24OV - 20A
B1 B2
1.80
2.30
(58.4)
+
+
.250 X .032 FASTON
TERMINAL
(4 PLACES)
.187 X .032
FASTON
TERMINAL
(4 PLACES)
40
20
0
20
10
30
50
40
10
20
30
40
50
60
70
80
Load Current [Arms]
Max Ambient Temp. [C]
Max Allowable Base Temp. [

C]
Power Dissipation [W]
25A LIMIT
(1 SECTION)
50A LIMIT
(2 SECTIONS)
95
105
75
85
0.5C/W
1.0C/W
2.0C/W
5.0C/W
240V Model
B1
LOAD B
B2
A2
A1
120/240Vrms
120/240Vrms
-- B CONTROL
+ B CONTROL
-- A CONTROL
+ A CONTROL
LOAD A
100
80
60
40
20
0
40
20
60
100
80
10
20
30
40
50
60
70
80
Load Current [Arms]
Max Ambient Temp. [C]
Max Allowable Base Temp. [

C]
Power Dissipation [W]
40A LIMIT
(1 SECTION)
80A LIMIT
(2 SECTIONS)
100
105
90
95
1.0C/W
2.0C/W
5.0C/W
0.5C/W
480V Model
B1
LOAD B
B2
A2
A1
480Vrms
480Vrms
+ B CONTROL
-- B CONTROL
LOAD A
-- A CONTROL
+ A CONTROL
W IRING DIAGRAM S
25A
40A
Example:
D2440D-10
For recommended applications and more information contact:
USA: Sales Support (877) 502-5500 Tech Support (877) 702-7700 FAX (619) 710-8540
Crydom Corp, 2320 Paseo de las Americas, Ste. 201, San Diego, CA 92154
Email: sales@crydom.com WEB SITE: http://www.crydom.com
UK: +44 (0)1202 365070 FAX +44 (0)1202 365090 Crydom International Ltd., 7 Cobham
Road, Ferndown Industrial Estate, Ferndown, Dorset BH21 7PE, Email: intsales@crydom.com.
GERMANY: +49 (0)180 3000 506