ChipFind - документация

Электронный компонент: NG5NADC3V

Скачать:  PDF   ZIP
Features
Small size, light weight.
Switching capacity up to 5A.
Low coil power consumption 0.2W.
Suitable for household electrical appliance, automation system, electronic equipment, instrument, meter,
telecommunication facilities and remote control facilities.
Ordering Information
NG5N A DC12V
1 2 3
1 Part number
NG5N
2 Contact Arrangement
A:1A
3 Coil rated Voltage(V)
DC:3,5,6,9,12,18,24
Contact Data
Contact Arrangement
1A SPSTNO
Contact Material
Silver Alloy
Contact Rating (resistive)
5A/30VDC,250VAC
Max. Switching Power
150W 1250VA min Switching load:10mA/5V
Max. Switching Voltage
30VDC 250VAC Max. Switching Current:5A
Contact Resistance or Voltage drop
100m Item 3.12 of IEC255-7
Electrical
10
5
Item 3.30 of IEC255-7
Operation
life
Mechanical
10
7
Item 3.31 of IEC255-7
CAUTION:
Relays previously tested or used above 10mA resistive at 6VDC maximum or peak AC open circuit are not
recommended for subsequent use in low level applications.
Coil Parameter
Coil voltage
VDC
Dash
Numbers
Rated
Max.
Coil
resistance
10%
Pickup
voltage
VDC(max)
(75%of rated
voltage )
release voltage
VDC(min)
(10% of rated
voltage)
Coil power
consumption
W
Operate
Time
ms
Release
Time
ms
003-200
3
3.9
45
2.25
0.3
005-200
5
6.5
125
3.75
0.5
006-200
6
7.8
180
4.50
0.6
009-200
9
11.7
405
6.75
0.9
012-200
12
15.6
720
9.00
1.2
018-200
18
23.4
1620
13.5
1.8
024-200
24
31.2
2880
18.0
2.4
0.2
10
4
CAUTION
: 1.The use of any coil voltage less than the rated coil voltage will compromise the operation of the relay.
2.Pickup and release voltage are for test purposes only and are not to be used as design criteria.
41
N G 5 N
20.5
7.2
15.3
www.dblectro.com
Operation condition
Insulation Resistance
1000M min (at 500VDC)
Item 7 of IEC255-5
Dielectric Strength
Between contacts
Between contact and coil
50Hz 750V
50Hz 4000V surge voltage:7kV
Item 6 of IEC255-5
Item 6 and 8 of IEC255-5
Shock resistance
Functional:100m/s
2
11ms Survival:1000m/s
2
6ms
IEC68-2-27 Test Ea
Vibration resistance
10~50Hz Functional & Survival double amplitude 1.5mm
IEC68-2-6 Test Fc
Terminals strength
5N
IEC68-2-21 Test Ua1
Solderability
235
x
2
3
x
0.5s
IEC68-2-20 Test Ta method 1
Ambient Temperature
-30~70
Relative Humidity
20%~85% (at 40
)
IEC68-2-3Test Ca
Mass
4g
Qualification inspection:
Perform the qualification test as specified in the table
of IEC255-19-1 and minimum sample size 24.
Dimensions (Unit: mm)
NOTES
1).Dimensions are in millimeter.
2).Inch equivalents are given for general information only.
NG5N
Dimensions
Wiring diagram
(Bottom views)
Mounting (Bottom views)
mm
>
0.27
0.011
0.52
0.020
0.8
0.031
1.05
0.041
1.1
0.043
1.2
0.047
3.4
0.134
4.7
0.185
7
0.275
7.2
0.283
11.5
0.453
15.3
0.602
20.5
0.807
www.dblectro.com