ChipFind - документация

Электронный компонент: 564-0100-777

Скачать:  PDF   ZIP
4-43
Dialight Corporation 1501 Route 34 South Farmingdale, NJ 07727 TEL: (732) 919-3119 FAX: (732) 751-5778 www.dialight.com
4
3mm
LED CBI
Circuit Board Indicator
Tri-Level
564-0x00-xxx
11.56
[.455]
REF
A
4.45[.175]
.010
2.54 [.100]
.010
2.54 [.100]
.010
2.54
[.100]
5.08
[.200]
15.24
[.600]
4.32
[.170]
MAX
3.68
[.145]
.010
5.08
[.200]
( TYP )
5.08 [.200]
.010
CATHODE ID
RED CATHODE LEAD
YEL CATHODE LEAD
(BI-COLOR LEDs)
POS.1
POS.2
POS.3
TOP LED
5.08
[.200]
2.54
[.100]
.002
2.54
[.100]
.002
1.09 [.043]
.002 ( 6X )
Dimension A:
Red/Green Bi-color 2.76 [.109
.015] all other colors 2.67 [.103 +- .015]
2.54
[.100]
.002
PART NO.
COLOR*
HIGH EFFICIENCY - LED TYPE 01
564-0100-111
Red-Red-Red
564-0100-132
Red-Yellow-Green
564-0100-222
Green-Green-Green
564-0100-777
Orange-Orange-Orange
564-0100-999
Blue-Blue-Blue
LOW CURRENT - LED TYPE 02
564-0200-111
Red-Red-Red
564-0200-132
Red-Yellow-Green
564-0200-222
Green-Green-Green
INTEGRAL RESISTOR, 5 VOLTS - LED TYPE 03
564-0300-111
Red-Red-Red
564-0300-132
Red-Yellow-Green
564-0300-222
Green-Green-Green
BI-COLOR - LED TYPE 07
564-0700-111
Red
/
Green-Red
/
Green-Red
/
Green
564-0700-444
Yellow
/
Green-Yellow
/
Green-
Yellow
/
Green
* Top-Middle-Bottom LED
Features
Multiple CBIs form horizontal LED arrays on 4.45mm
(0.175") center-lines.
High Contrast, UL 94 V-0 rated, black housing
Oxygen index: 29%
Polymer content: PBT, 0.078 g
Housing stand-offs facilitate PCB cleaning
Solderability per MIL-STD-202F, method 208F
LEDs are safe for direct viewing per IEC 825-1,
EN-60825-1
Tolerance note: As noted, otherwise:
LED Protrusion: 0.04 mm [0.016]
CBI Housing: 0.02mm[0.008]
Custom Combinations
Contact factory for information on custom
color combinations
Dimensions in mm [inches]
5 6 4 - 0 x 0 0 - x x x
Top LED Position
Bottom LED
Position
Middle LED Position
LED Type
Series
PART NUMBER ORDERING CODE
Color = 0) Blank 1) Red or Red/Green Bi-color 2) Green 3) Yellow
4) Yellow/Green Bi-color 7) Orange 8) Blue
NEW
ATTENTION
OBSERVE PRECAUTIONS
FOR HANDLING
ELECTROSTATIC
SENSITIVE
DEVICES