DIONICS, INC.
Phone: (516) 997-7474
65 Rushmore Street Fax: (516) 997-7479
Westbury, NY 11590 Website: www.dionics-usa.com
LEVEL-SHIFTED GAS DISCHARGE DISPLAY DIGIT DRIVERS
DI-500B DI-502B
General Description:
The DIONICS DI-500B and DI-502B circuits are designed for
interfacing between MOS or TTL circuitry and gas discharge
display panels. Each section of these devices is made up of a
switched constant current level shifter-capable of high voltage
operation-and a pnp-npn driver transistor pair. The constant
current operation of the level shifter stage results in low power
dissipation. Input circuitry is suitable for open drain PMOS,
CMOS, open-collector or standard TTL.
Features:
Level Shift Capability: 125V For DI-502B
200V For DI-500B
MOS and TTL Compatibility
Pin For Pin Replacements For Sprague UDN-6144A
Low Power Dissipation
Reliable Dielectric Isolation Process
Package Layout:
0.760 Max.
0.070
DIONICS INC
DI-500B
0.185
0.020
0.025
0.250
01/2002
V+
Circuit Schematic
(Each Section)
Output
Input
3
Out2
2
NC
Pin Connections
Out1
NC
13
In4
In3
1
In2
In1
11
GND
10
V +
9
14
8
7
NC
6
NC
5
Out4
4
Out3
12
Absolute Maximum Rating (Ta = 25
0
C)
Characteristic
Symbol
Notes
Limits
Units
Supply Voltage DI-500B
DI-502B
V +
V +
Measured With Respect to GND
Measured With Respect to GND
200
125
V
V
Input Voltage
V
in
Measured With Respect to GND
35
V
Output Voltage
V
out
Measured With Respect to V + Terminal
90
V
Output Current
I
out
40
mA
Power Dissipation DI-500B
P
D
Derate at 6 mW/
0
C Above 25
0
C Ambient
600
mW
DI-502B
P
D
Derate at 6 mW/
0
C Above 25
0
C Ambient
600
mW
Storage Temperature
T
s
-55 to +125
0
C
Operating Temperature
T
o
0 to +70
0
C
Electrical Characteristics (Ta = 25
0
C)
Parameter
Symbol
Notes
Conditions
Typ. Max. Units
Output Saturation
Voltage
V
out
(SAT)
V + = 180V (DI-500B);
V+ = 100V (DI-502B);
Measured With Respect to
V+ Terminal.
I
o
= 25mA;
V
i
= 2.4V
3
10
V
Output Leakage Current I
out
(OFF)
V + = 180V (DI-500B);
V+ = 100V (DI-502B).
V
o
= 90V; V
i
= 0.4V 0.1 10 A
Input Current
I
in
(ON)
V
i
= 2.4V
340 400 A
Supply Current
I+
V + = 180V (DI-500B);
V+ = 100V (DI-502B);
One Input at 3.5V, Others
at 0.4V.
V
i
= 2.4 V; I
o
= 0 0.5 2.0 mA
Typical Application:
Vss
5
To
Setting
Circuit
4
19
Vdd
5
15
9
-15 V
CLOCK / CALENDAR CT- 7001
7
Sa
16
Spm
11
60 Hz
8
27
DIONICS INC. DI-500B
D4
18
Sg
10
7
-15V
24
D3
BURROUGHS
CD-4073-GM
Sf
6
D2
Spm
Se
4
18
D1
Sg
Sd
IN3
3
17
8
Sf
Sc
IN2
-15 V
16
Sb
9
IN1
15
Sa
8
D1
13
10
Se
150pF
1.5K
17
23
D2
12
11
Sd
+180 V
2
0.01
14
25
D3
11
12
Sc
1
26
D4
10
14
Sb
27K
DIONICS INC. DI-210
22
3
14
1
21
Vz = 7V
1
4
5
3
20
V in
+ 200V
+
GND
-
R load
2.5K
Simplified Test Circuit
+
-
V +