ChipFind - документация

Электронный компонент: SKO6

Скачать:  PDF   ZIP
SKO2 - SKOB
SURFACE MOUNT
SCHOTTKY BARRIER RECTIFIERS
PRV : 20 - 100 Volts
I
O
: 1.5 Amperes
FEATURES :
* High current capability
* High surge current capability
* High reliability
* High efficiency
* Low power loss
* Low forward voltage drop
* Low cost
MECHANICAL DATA :
* Case : SMA Molded plastic
* Epoxy : UL94V-O rate flame retardant
* Lead : Lead Formed for Surface Mount
* Polarity : Color band denotes cathode end
* Mounting position : Any
* Weight : 0.064 gram
MAXIMUM RATINGS AND ELECTRICAL CHARACTERISTICS
Rating at 25
C ambient temperature unless otherw ise specified.
Single phase, half w ave, 60 Hz, resistive or inductive load.
For capacitive load, derate current by 20%.
SYMBOL
SK
O2
SK
O3
SK
O4
SK
O5
SK
O6
SK
O7
SK
O8
SK
O9
SK
OB
UNIT
Maximum Recurrent Peak Reverse Voltage
V
RRM
20
30
40
50
60
70
80
90
100
Volts
Maximum RMS Voltage
V
RMS
14
21
28
35
42
49
56
63
70
Volts
Maximum DC Blocking Voltage
V
DC
20
30
40
50
60
70
80
90
100
Volts
Maximum Average Forward Current Fig.1
I
F(AV
)
1.5
Amp.
Peak Forward Surge Current, 8.3ms single half sine wave
superimposed on rated load (JEDEC Method)
I
FSM
50
Amp.
Maximum Forward Voltage at I
F
= 1.5 Amp. (Note 1)
V
F
0.5
0.7
0.79
Volt.
Maximum Reverse Current at
Rated DC Blocking Voltage (Note 1)
I
R
0.5
mA
Junction Temperature Range
T
J
- 65 to + 125
- 65 to + 150
C
Storage Temperature Range
T
STG
- 65 to + 150
C
Notes :
(1) Pulse Test : Pulse Width = 300
s, Duty Cycle = 2%.
UPDATE : SEPTEMBER 12, 1998
RATING
2.0
0.2
2.1
0.2
SMA (DO-214AC)
1.2
0.2
5.0
0.15
4.5
0.15
2.6
0.15
Dimensions in millimeter
1.1
0.2
0.07
RATING AND CHARACTERISTIC CURVES ( SKO2 - SKOB )
FIG.1 - FORWARD CURRENT DERATING CURVE
FIG.2 - MAXIMUM NON-REPETITIVE PEAK
FORWARD SURGE CURRENT
0
25
50
75
100
125
150
175
1
2
4
6
10
20
40
60
100
LEAD TEMPERATURE, (
C)
NUMBER OF CYCLES AT 60Hz
FIG.3 - TYPICAL FORWARD CHARACTERISTICS
FIG.4 - TYPICAL REVERSE CHARACTERISTICS
0.1
0.3
0.5
0.7
0.9
1.1
1.3
1.5
1.7
1.9
2.1
1.2
0.9
0.6
0.3
1.5
40
0
50
0
30
20
10
PEAK FORWARD SURGE
CURRENT, AMPERES
AVERAGE FORWARD CURRENT,
AMPERES
10
1.0
80
0.01
0.1
100
140
0
20
40
60
120
PERCENT OF RATED REVERSE
VOLTAGE, (%)
T
J
= 100
C
T
J
= 25
C
REVERSE CURRENT, MILLIAMPERES
SKO2
SKO3
SKO4
SKO5
THRU
SKOB
1.0
0.1
10
FORWARD CURRENT, AMPERES
FORWARD VOLTAGE, VOLTS
20
SKO8
SKO9
SKOB
T
J
= 25
C
PULSE WIDTH = 300
s
DUTY CYCLE = 2%
SKO2
SKO3
SKO4
SKO5
SKO6
SKO7