LCF Enterprises
6180 Commerce Loop
Tel: 208-415-4300
Post Falls, ID 83854
FAX: 208-415-4306
E-Mail:
info@lcfamps.com
Web: www.lcfamps.com
OPEN ARCHITECTURE FEATURES
1. Separate bias inputs and power supply feed throughs permit either Class A or Class AB biasing. Bias off disables amplifier
2. Separate power supply terminals for each push/pull section permit individual fuse protection.
3. A low loss output matching network provides high efficiency and optimum stability.
OPTIONS AVAILABLE
Higher powers through multiple module combining
Inside wiring with only one DC connection
Detailed Application Notes
Transmit/Receive Subsystems
TTL compatible enable/disable control
Narrower band optimization. ( no additional cost)
Complete rackmount 120/220 VAC systems
Test fixture with heat sink, fuse protection, and thermal
Model A072
P/N 500-30-100-35-E3
RF POWER
AMPLIFIER MODULE
30 - 500 MHz
100 Watts
Gain: 35 dB Voltage: 28 VDC
PERFORMANCE
Small Size
High Efficiency
Low Even Order Harmonics
Rugged
PARAMETER
SPECIFICATIONS
COMMENTS
RF Output Power
100 Watts cw minimum
Class AB linear
Frequency Range
30 - 500 MHz
Gain
35 dB minimum
40 dB typical
Main DC Supply
28 VDC, 12 Amp maximum
8 to 11 Amp typical at 100 W output
(see Note 1)
Bias Supply
15 VDC, 10 mA maximum
Provides enable/disable control (see Note 2)
Efficiency
35 - 45 % typical
Harmonics / Spurious
See Plot / Spurious <-60 dBc
In / Out Impedance
Designed for small size, high efficiency;
compatible with 50 ohms
RF In / Out Connectors
SMA Female
DC Connectors
Solderable filtered feed throughs with ground
lugs
Size / Weight
6.0" x 2.5" x 1.25" / < 1 lb.
Operating Temperature
-50
B
C to +60
B
C
Consult technical support for higher
temperature operation.
Humidity
95 - 100 %
Vibration
110 G Shock
Altitude
50,000 feet