ChipFind - документация

Электронный компонент: 80C08C

Скачать:  PDF   ZIP
Features & Benefits
10 Gb/s Telecom & Datacom
80C08C and 80C12 Low-
noise, High Optical Sensitivity
and Broad Wavelength
Conformance Testing for
10GbE LAN, WAN, and FEC,
10G Fibre Channel, and
10 Gb/s Telecom Standard
and FEC Rates
80C11 30 GHz Optical
Bandwidth Conformance
Testing and Characterization
for 10 Gb/s Telecom and
Datacom Standards and
FEC Rates
80C08C and 80C11
Integrated Clock Recovery
Supports All Current 10 Gb/s
Standards or User Defined
Rate from 9.8 to 12.6 Gb/s
80C12 Clock Recovery
Available Via 80A05 Clock
Recovery Module
40 Gb/s Telecom
80C10 Provides 65 GHz
Optical Bandwidth for Signal
Characterization of 40 Gb/s
RZ or NRZ Data
80C10 Provides Reference
Receivers for Conformance
Testing of 39.813 Gb/s
(OC-768/STM-256)
and 43.018 Gb/s
(ITU-T G.709 FEC)
Tributary Telecom & Datacom
80C07B and 80C12 Provide
Excellent Optical Sensitivity
and Broad Wavelength
Test Capability
80C07B, 80C12, 80C01
Multi-rate Telecom
Conformance Testing
Solutions from 155 Mb/s
(OC-3/STM-4) Through
9.953 Gb/s (OC-192/
STM-64) and Datacom
Conformance Testing
Solutions for Fibre Channel,
Ethernet and InfiniBand
Standards
Applications
High-speed Optical
Communications Testing
Extinction Ratio and Q-factor
Measurements
Eye-pattern and Pulse
Shape Analysis
Relaxation Oscillation Testing
Optical Signal Analysis
Conformance Testing
NRZ and RZ Pulse
Characterization
O p t i c a l S a m p l i n g M o d u l e s
80C01
80C02
80C07B
80C08C
80C10
80C11
80C12
Optical Signal Analysis
www.tektronix.com/optical
1
The CSA/TDS8000B Series Sampling
Oscilloscopes, when configured with one
or more optical sampling modules, provide
complete optical test solutions for Telecom
(155 Mb/s to 43.018 Gb/s) or Datacom
(Fibre Channel, Gigabit Ethernet, 10GbE
and InfiniBand) applications, as well as
general purpose optical component testing.
Each optical module includes all the elements
necessary for optical testing:
Optical to electrical converter
Average power monitor
One or more reference receiver filters
A full bandwidth optical path
A low-noise electrical sampler
Optional integrated clock recovery (80C12
clock recovery is provided via the 80A05
Clock Recovery Module sold separately)
Universal optical input connector
80C01 Multi-rate Telecom Sampling
Module The 80C01 module supports
waveform conformance testing of long-
wavelength (1100 to 1650 nm) signals at
622, 2488 Mb/s and 9.953 Gb/s as well
as general-purpose testing with up to
20 GHz optical bandwidth. With its clock
recovery option, the 80C01 provides
testing solutions for 622 and 2488 Mb/s
telecom applications.
80C02 High-performance Telecom
Sampling Module The 80C02 module
is optimized for testing of long-wavelength
(1100 to 1650 nm) signals at 9.953 Gb/s
(SONET OC-192/SDH STM-64). With its
high optical bandwidth of 30 GHz (typical),
it is also well-suited for general purpose,
high-performance optical component testing.
The 80C02 can be optionally configured
with clock recovery that supports
9.953 Gb/s telecom standards.
CSA/TDS8000B Series Sampling Oscilloscope
Optical Modules
Optical Signal Analysis
www.tektronix.com/optical
2
Optical Sampling Modules
80C01
80C02
80C07B
80C08C
80C10
80C11
80C12
80C07B Multi-rate, Datacom & Telecom
Optical Sampling Module The 80C07B
module is a broad wavelength (700 to
1650 nm) multi-rate optical sampling module
optimized for testing datacom/telecom
signals from 155 to 2500 Mb/s. With its
amplified O/E converter design, this module
provides excellent signal-to-noise perform-
ance, allowing users to examine low-power
optical signals. The 80C07B can be option-
ally configured with clock recovery that sup-
ports 155, 622, 1063, 1250, 2125, 2488,
2500 and 2666 Mb/s rates.
80C08C Multi-rate, Datacom & Telecom
Optical Sampling Module with 10GbE
Forward Error Correction The 80C08C
module is a broad wavelength (700 to
1650 nm) multi-rate optical sampling module
providing datacom rate testing for 10GbE
applications at 9.953, 10.3125, 11.0957 Gb/s
and 10G Fibre Channel applications at
10.51875 Gb/s. The 80C08C also provides
telecom rate testing at 9.953, 10.664, and
10.709 Gb/s. With its amplified O/E converter
design, this module provides excellent signal-
to-noise performance and high optical
sensitivity, allowing users to examine low-
power level optical signals. The 80C08C
can be optionally configured with clock
recovery options that can support any stan-
dard or user defined rate in the continuous
range from 9.8 to 12.6 Gb/s.
80C10 65 GHz 40 Gb/s Optical Sampling
Module with 43 Gb/s ITU-T G.709
Forward Error Correction The 80C10
module provides integrated and selectable
reference receiver filtering, enabling
conformance testing at either 1310 nm or
1550 nm for 39.813 Gb/s (OC-768/STM-
256) and 43.018 Gb/s (43 Gb/s ITU-T
G.709 FEC) rates. In addition to the filter
rates, the user may also choose selectable
bandwidths of 30 GHz or 65 GHz for optimal
noise vs. bandwidth performance for accu-
rate signal characterization. The 80C10 is
optionally available in a bundled ordering
configuration which includes a 70+ GHz
electrical sampling channel.
80C11 Multi-rate, Datacom & Telecom
Optical Sampling Module The 80C11
module is a long wavelength (1100 to
1650 nm) multi-rate optical sampling module
optimized for testing 10 Gb/s datacom
and telecom standard rates at 9.953,
10.3125, 10.51875, 10.664, 10.709, and
11.0957 Gb/s. With its high optical band-
width of up to 30 GHz (typical) it is well-
suited for general purpose high-performance
10 Gb/s optical component testing. The
80C11 can be optionally configured with
clock recovery options that can support any
standard or user defined rate in the contin-
uous range from 9.8 to 12.6 Gb/s.
80C12 Multi-rate, Datacom & Telecom
Optical Sampling Module The 80C012
module is a broad wavelength (700 to 1650
nm) multi-rate optical sampling module pro-
viding 1G, 2G, and 4G telecom and datacom
testing. This highly flexible module can be
configured to support either lower data rate
applications (1 to 4 Gb/s) or a wide variety
of 10 Gb/s applications. The low data rate
applications include: 1, 2, and 4 Fibre Channel
and "by 4" wavelength division multiplex
standards such as 10G Base-X4 and 4-Lane
10 Gb/s Fibre Channel. The supported 10
Gb/s application includes both datacom and
telecom application. The supported 10 Gb/s
datacom applications include 10GbE appli-
cations at 9.953, 10.3125, 11.0957 Gb/s
and 10G Fibre Channel applications at
10.51875 Gb/s. The 80C12 also provides
telecom rate testing at 9.953, 10.664, and
10.709 Gb/s. With its amplified O/E con-
verter design, this module provides excellent
signal-to-noise performance and high optical
sensitivity, allowing users to examine low-
power level optical signals. Clock recovery
for the 80C12 is provided via the 80A05
(sold separately).
Optical Signal Analysis
www.tektronix.com/optical
3
Optical Sampling Modules
80C01
80C02
80C07B
80C08C
80C10
80C11
80C12
O p t i c a l M o d u l e s
Module
80C01
80C02
80C07B
Option
CR
CR
F1
F2
F3
F4
F5
F6
F7
F8
F9
F10
CR1
Bandwidth 20
20
30
30
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
(GHz)
Wavelength 1100-
1100-
1100-
1100-
700- 700- 700- 700- 700- 700- 700- 700- 700- 700- 700-
Range (nm)
1650
1650
1650
1650
1650
1650
1650
1650
1650
1650
1650
1650
1650
1650
1650
Fiber Input
9
9
9
9
9 &
9 &
9 &
9 &
9 &
9 &
9 &
9 &
9 &
9 &
9 &
(m)
62.5
62.5
62.5
62.5
62.5
62.5
62.5
62.5
62.5
62.5
62.5
Mask Test
8
8
9
9
22
22
22
22
22
22
22
22
22
22
22
Sensitivity
(dBm)
Number of
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
Channels
Rates Supported:
= Filter,
= Optical Clock Recovery,
= Electrical Clock Recovery
155 Mb/s
622 Mb/s
1063 Mb/s
1250 Mb/s
2125 Mb/s
2488 Mb/s
2500 Mb/s
3.125 Gb/s
3.188 Gb/s
3.32 Gb/s
4.25 Gb/s
9.95 Gb/s
Optical Signal Analysis
www.tektronix.com/optical
4
Optical Sampling Modules
80C01
80C02
80C07B
80C08C
80C10
80C11
80C12
O p t i c a l M o d u l e s ( c o n t i n u e d )
Module
80C08C
80C10
80C11
Option
CR1
CR2
CR4
CR1
CR2
CR3
CR4
Bandwidth
10
10
10
10
65
30
30
30
30
30
(GHz)
Wavelength 700-1650
700-1650
700-1650
700-1650
1290-1330
1100-1650
1100-1650
1100-1650
1100-1650
1100-1650
Range (nm)
1530-1570
Fiber Input
9 &
9 &
9 &
9 &
9
9
9
9
9
9
(m)
62.5
62.5
62.5
62.5
Mask Test
15
15
15
15
0
9
9
9
9
9
Sensitivity (dBm)
Number of
1
1
1
1
1
1
1
1
1
1
Channels
Rates Supported:
= Filter,
= Optical Clock Recovery,
= Electrical Clock Recovery
9.95 Gb/s
10.31 Gb/s
10.52 Gb/s
10.66 Gb/s
10.71 Gb/s
11.1 Gb/s
39.81 Gb/s
43.02 Gb/s
Optical Signal Analysis
www.tektronix.com/optical
5
Optical Sampling Modules
80C01
80C02
80C07B
80C08C
80C10
80C11
80C12
O p t i c a l M o d u l e s ( c o n t i n u e d )
Module
80C12
Option
F1
F2
F3
F4
F5
F6
FC
10G
CR*
1
CR*
2
Bandwidth 4.25
9
9
4.25
9
9
9
10
(GHz)
Wavelength 700-1650
700-1650
700-1650
700-1650
700-1650
700-1650
700-1650
700-1650
Range (nm)
Fiber Input
9 &
9 &
9 &
9 &
9 &
9 &
9 &
9 &
(m)
62.5
62.5
62.5
62.5
62.5
62.5
62.5
62.5
Mask Test
15
15
15
15
15
15
15
12
Sensitivity (dBm)
Number of
1
1
1
1
1
1
1
1
Channels
Rates Supported:
= Filter,
= Optical Clock Recovery,
= Electrical Clock Recovery
155 Mb/s
622 Mb/s
1063 Mb/s
1250 Mb/s
2125 Mb/s
2488 Mb/s
2500 Mb/s
3.125 Gb/s
3.188 Gb/s
3.32 Gb/s
4.25 Gb/s
9.95 Gb/s
10.31 Gb/s
10.52 Gb/s
10.66 Gb/s
10.71 Gb/s
11.1 Gb/s
*
1
With 80A05.
*
2