CITFUSE Website: www.citfuse.com Tel: 763-535-2339 Fax: 763-535-2194
CIRCUIT INTERRUPTION TECHNOLOGY INC.
A-0709
SPECIFICATIONS
E198027
ORDERING INFORMATION
DIMENSIONS
PANEL CUT OUT
Electrical Ratings
3.0 - 16A @ 125/250VAC
4.0 16A @ 125 (UL/CUL)
Dielectric Strength
1500Vrms min
Insulation Resistance
> 100M
min
Interrupt Capacity
125VAC, 1000A; 250VAC, 1000A
Contact Endurance
125VAC X 150% of rated current - 500 cycles
Calibration
25
C 105% of rated current - continuously carried
25
C 106% to 134% - may trip or not
25
C 135% of rated current - trip within 1 hour
150% of 4A trip within 1 hour
25
C 200% of rated current - trip within 1 minute
Reset Manual
reset
Internal Resistance
3A 5A
0.120
5.1A 6A
0.100
6.1A 7A
0.075
7.1A 8A
0.035
8.1A 9A
0.020
9.1A 12A
0.015
12.1A 14A
0.010
14.1A 16A
0.008
Derating Factor
TEMP 3.0A-4.0A 4A-16A
60
C
--- X
0.50
55
C
--- X
0.60
50
C
--- X
0.70
45
C
X 0.45
X 0.75
40
C
X 0.55
X 0.80
35
C
X 0.70
X 0.86
30
C
X 0.80
X 0.92
25
C
X 1.00
X 1.00
20
C
X 1.10
X 1.06
15
C
X 1.20
X 1.09
10
C
X 1.35
X 1.20
1. Series
A-0709
A-0709
2. Style
P = 7/16" 28T bushing, Manual Reset
P
3. Current Rating:
3A 16A
3A
4. Reset Button Color:
B = Black (White Printing)
W = White (Black Printing)
B
5. Hardware:
C = 1 Hex Nut, 1 Name Plate
D = 1 Knurled Nut, 1 Name Plate
E = 1 Hex Nut, 1 Knurled Nut, 1 Name Plate
F = 2 Knurled Nuts, 1 Name Plate
G = 2 Hex Nuts, 1 Name Plate
C