ChipFind - документация

Электронный компонент: D4DS-6AFS

Скачать:  PDF   ZIP

Document Outline

D4DS
2
Safety-Door Switch
Compact Safety Switch Saves Space
and is Ideal for a Variety of Doors
H
Conforms to EN (TV) standards. (positive
opening mechanism
is indicated on the
switch)
H
Wide standard operating temperature
range: --30 to 70C
H
Double-insulation structure (with
mark)
requires no grounding terminals
H
Five-direction Operation Key
H
Approved by UL, CSA, BIA and SUVA
standards
H
Standards and EC Directives:
Conforms to the following EC Directives:
Machinery Directive
Low Voltage Directive
EN50047
EN1088
H
Approved Standards
Agency
Standard
File No.
TV Rheinland
EN60947-5-1
R9551708
(Positive opening:
approved)
UL (see note)
UL508
CSA C22.2 No.14
E76675
BIA
GS-ET-15
1-conduit: 9509915
2-conduit: 9509913
SUVA
SUVA
1-conduit: 6010Z
2-conduit: 6011Z
Note: CSA C22.2 No. 14 compliance was verified and approved
by UL (Marked with
).
E
u
886-3-5753170
86-755-83289224
Http://www.100y.com.tw
D4DS
3
Ordering Information
J
MODEL NUMBER LEGEND
Switch
1.
Conduit size/type
1:
Pg13.5
(1-conduit, European type)
2:
G1/2 (1-conduit, Japanese type)
3:
1/2-14NPT
(1-conduit, North American type)
5:
Pg13.5 (2-conduit)
(1-conduit, European type)
6:
G1/2 (2-conduit Japanese type)
2.
Built-in Switch
5:
1NC/1NO (Slow-action)
A:
2NC (Slow-action)
3.
Head Mounting Direction
F:
Four mounting directions pos-
sible (Front-side mounting at
shipping)
1.
Operation Key Type
1:
Horizontal mounting
2:
Vertical mounting
3:
Adjustable mounting (Horizontal)
5:
Adjustable mounting (Horizontal/
Vertical)
D4DS-Kj
1
Operation Key
D4DS-jjjS
1
2
3
Note: An order for the head part or the switch part alone cannot be accepted.
The Operation Key is sold separately.
J
SWITCHES
Description
Part number
Appearance
Conduit size/type
1NC/1NO (Slow-action)
2NC (Slow-action)
1-conduit
Pg13.5 (European)
D4DS-15FS
D4DS-1AFS
G1/2 (Japanese)
D4DS-25FS
D4DS-2AFS
1/2-14NPT (North American)
D4DS-35FS
D4DS-3AFS
2-conduit
Pg13.5 (European)
D4DS-55FS
D4DS-5AFS
G1/2 (Japanese)
D4DS-65FS
D4DS-6AFS
J
OPERATION KEYS (ORDER SEPARATELY)
Type
Part number
Horizontal mounting
D4DS-K1
Vertical mounting
D4DS-K2
Adjustable mounting (Horizontal)
D4DS-K3
Adjustable mounting (Horizontal/Vertical)
D4DS-K5
886-3-5753170
86-755-83289224
Http://www.100y.com.tw
D4DS
4
Specifications
J
APPROVED STANDARD RATINGS
TV (EN60947-5-1)
Utilization category
AC-15
Rated operating current (I
e
)
2 A
Rated operating voltage (U
e
)
400 V
Note: Use a 10-A fuse type gl or gG as a short-circuit protection device that conforms to IEC269.
UL (UL508/CSA C22.2 No.14)
A600
Rated voltage
Carry current
Current
Volt-amperes
y
Make
Break
Make
Break
120 VAC
10 A
60 A
6 A
7,200 VA
720 VA
240 VAC
30 A
3 A
480 VAC
15 A
1.5 A
600 VAC
12 A
1.2 A
J
CHARACTERISTICS
Degree of protection (see note 1)
IP65 (EN60947-5-1)
Life expectancy (see note 2)
Mechanical: 1,000,000 operations min.
Electrical: 150,000 operations min.
Operating speed
0.1 m/s to 0.5 m/s
Contact gap
2 x 2.0 mm min.
Operating frequency
30 operations/minute min.
Positive opening force (see note 3)
58.84 N min.
Positive opening travel (see note 3)
10 mm min.
Insulation resistance
100 M min. (at 500 VDC) between terminals of same polarity, between terminals of
different polarity, between each terminal and ground, and between each terminal and
non-current-carrying metal part
Contact resistance
25 m max. (initial value)
Dielectric strength
U
imp
4 kV between terminals of same polarity, between terminals of different polarity, and
between each terminal and non-current-carrying metal part (EN60947-5-1)
Rated insulation voltage (U
i
)
400 V (EN60947-5-1)
Conditional short-circuit current
100 A (EN60947-5-1)
Short-circuit protective device (SCPD)
10 A, fuse type gI or gG (IEC269)
Switching overvoltage
1,500 V max. (EN60947-5-1)
Pollution degree (operating environment)
3 (EN60947-5-1)
Conventional enclosed thermal current
(I
the
)
10 A (EN60947-5-1)
Protection against electric shock
Class II (double insulation)
Vibration resistance
Malfunction: 10 to 500 Hz, 0.65-mm single amplitude with an imposed acceleration of
100 m/s
2
max.
Shock resistance
Destruction: 1,000 m/s
2
min.
Malfunction: 300 m/s
2
min.
Ambient temperature
Operating: --30C to 70C (with no icing)
Ambient humidity
Operating: 95% max.
Weight
Approx. 76 g (for D4DS-15FS)
Note: 1. Although the Switch casing resists dust, oil, and water, make sure that the keyhole on the head is free from dust, oil, water, and
chemical, or the D4DS may wear out, break, or malfunction.
2. Life expectancy values are calculated at an operating temperature of 5C to 35C, and an operating humidity of 40% to 70%.
Contact your OMRON sales representative for more detailed information on other operating environments.
3. These figures are minimum requirements for safe operation.
886-3-5753170
86-755-83289224
Http://www.100y.com.tw
D4DS
5
J
OPERATING CHARACTERISTICS
1-Conduit/2-Conduit Models
Model
D4DS-jjjS
Operating force (extraction)
14.71 N
Release force (insertion)
29.42 N
Pretravel
63 mm
Total travel (reference value)
28 mm
Min. positive opening force (see note)
58.84 N
Min. positive opening stroke (see note)
10 mm
Note: Make sure that the positive opening stroke is at least 16 mm in order to use the D4DS safely.
Nomenclature
Operation Key
The dedicated key prevents operational mistakes and forci-
bly separates the contacts.
Head
The head can be mounted in four directions. The Opera-
tion Key can be inserted in five directions including the
downward direction.
Cover
The cover, with a hinge on its lower part, can be opened
by removing the screw of the cover, which ensures ease
of maintenance and wiring.
Built-in Switch
Has a positive opening mechanism which forcibly separates
the NC contacts even if they are welded.
The built-in switch incorporates a pair each of NC contacts
and NO contacts or two pairs of NC contacts.
Conduit
Wide switch variations.
Pg13.5:
1-conduit, 2-conduit models
G1/2:
1-conduit, 2-conduit models
1/2-14NPT: 1-conduit models
Oil Seal
The plunger has an O ring. The switch casing ensures
IP65 (except the keyhole, which ensures IP00). Use the
D4DS in places where the keyhole is free from oil and
metal chips.
Note: The housing and head of the D4DS are made of synthetic resin.
If high mechanical durability is required, use the D4BS Safety
Door Switch.
886-3-5753170
86-755-83289224
Http://www.100y.com.tw
D4DS
6
Operation
J
CONTACT FORM
(DIAGRAMS SHOW STATE WITH KEY INSERTED)
Model
Contact
Diagrams
Remarks
D4DS-j5jS 1NC/1NO
11
12
23
24
Zb
11 - 12
23 - 24
Stroke
ON
Operation Key
insertion comple-
tion position
Pull-out
completion
position
Only NC contact 11-12 has an
approved positive opening
mechanism.
The terminals 11-12 and 23-24 can
be used as unlike poles.
D4DS-jAjS 2NC
11
21
12
22
Zb
11 - 12
21 - 22
Stroke
ON
Operation Key
insertion comple-
tion position
Pull-out
completion
position
NC contacts 11-12 and 21-22 have
an approved positive opening
mechanism.
The terminals 11-12 and 23-24 can
be used as unlike poles.
Note: Terminals are numbered according to EN50013 and contacts are marked according to EN60947-5-1.
J
POSITIVE OPENING MECHANISM
1NC/1NO Contact (Slow-Action)
2NC Contact (Slow-Action)
Contact spring
Return spring
Fixed contact (NC)
Movable contact
Plunger
Fixed contact (NO)
Contact spring
Return spring
Fixed contact (NC)
Movable contact
Plunger
Only the NC contacts have a positive opening function.
When metal deposition occurs, the contacts are separated
from each other by pushing in the plunger.
Conforms to EN60947-5-1 Positive Opening
Both NC contacts incorporate a positive
opening function.
When metal deposition occurs, the contacts
are separated from each other by pushing in
the plunger.
Conforms to EN60947-5-1 Positive Opening
Note: The switches are marked with
indicating approval for the positive opening mechanism.
886-3-5753170
86-755-83289224
Http://www.100y.com.tw