M O D E L N U M B E R S
D C C O N T R O L
AC CONTROL
DC60S3
DC60S5
DC60S7
DC60SA3
DC60SA5
DC60SA7
OUTPUT SPECIFICATIONS
Operating Voltage Range [Vdc]
3-60
3-60
3-60
3-60
3-60
3-60
Load Current Range
[Adc]
.02-3
.02-5
.02-7
.02-3
.02-5
.02-7
Max. Surge Current, (1 sec) [Adc]
6
10
14
6
10
14
Max. On-State Voltage Drop @ Rated Current [Vdc]
1.3
1.5
1.7
1.3
1.5
1.7
Thermal Resistance Junction to Case (RJC ) [C/W]
2.2
2.2
2.2
2.2
2.2
2.2
Max. Off-State Leakage Current @ Rated Voltage [mA]
0.1
0.1
0.1
0.1
0.1
0.1
Max. Turn-On Time [msec]
0.1
0.1
0.1
10
10
10
Max. Turn-Off Time [msec]
0.3
0.3
0.3
40
40
40
INPUT SPECIFICATIONS
DC CONTROL
AC CONTROL
Control Voltage Range
3.5-32 Vdc
90-280 Vrms
Max. Turn-On Voltage
3.5 Vdc
90 Vrms
Min. Turn-Off Voltage
1.0 Vdc
10 Vrms
Nominal Input Impedence
1500 Ohms
60K Ohms
Typical Input Current
2.2mA @ 5 Vdc
2mA @ 120 Vrms, 4mA @ 240 Vrms
G E N E R A L N O T E S
All parameters at 25C unless otherwise specified.
Heat sinking required, for derating curves see page 2.
Cost Effective
Industry Standard Package
AC or DC Control
Panel M ount
FastFax Document No. 163
SERIES DC60.
Rev. 021202
PAGE 1 OF 2
Bipolar transistor outputs are available
in 3, 5 and 7 amp ratings. Cost-effec-
tive relays offer 4000 Volt isolation and
come in Crydom's standard panel-
mount package.
Manufactured in Crydom's ISO 9001
Certified facility for optimum product
performance and reliability.
Series DC60
3-7Amp 60 Vdc DC Output
2002 CRYDOM CORP, Specifications subject to change without notice.
For recommended applications and more information contact:
USA: Sales Support (877) 502-5500 Tech Support (877) 702-7700 FAX (619) 710-8540
Crydom Corp, 2320 Paseo de las Americas, Ste. 201, San Diego, CA 92154
Email: sales@crydom.com WEB SITE: http://www.crydom.com
UK: +44 (0)1202 365070 FAX +44 (0)1202 365090 Crydom International Ltd., 7 Cobham
Road, Ferndown Industrial Estate, Ferndown, Dorset BH21 7PE, Email: intsales@crydom.com.
GERMANY: +49 (0)180 3000 506
12
8
4
0
1
2
1.5
2.5
3
20
40
60
100
80
Load Current [Arms]
Max Ambient Temp. [C]
Power Dissipation
100
Base Plate Temp [

C]
3A
105
110
115
120
NO HEAT SINK
7.5C/W
12
8
4
0
1
2
4
5
3
20
40
60
100
80
Load Current [Arms]
Max Ambient Temp. [C]
Power Dissipation
100
Base Plate Temp [

C]
5A
105
110
115
120
NO HEAT SINK
5C/W
2C/W
7.5C/W
12
8
4
0
1
2
4
5
6
7
3
20
40
60
100
80
Load Current [Arms]
Max Ambient Temp. [C]
Power Dissipation
100
Base Plate Temp [

C]
7A
105
110
115
120
NO HEAT SINK
5C/W
2C/W
7.5C/W
GENERAL SPECIFICATIONS
Dielectric Strength 50/60Hz (input/output/base)
4000 Vrms
Insulation Resistance (Min.) @ 500 Vdc
10
9
Ohm
Max. Capacitance Input/Output
8 pF
Ambient Operating Temperature Range
-30 to 80C
Ambient Storage Temperature Range
-30 to 125C
M ECHANICAL SPECIFICATIONS
Weight: (typical)
3.0 oz. (86.5g)
Encapsulation: Thermally
Conductive
Epoxy
Terminals:
Screws and Saddle Clamps Furnished, Unmounted
1.87
(47.5)
.78
(19.8)
2.30
(58.4)
1.70
(43.2)
.90
(22.9)
.45
(11.4)
1.10
(27.9)
8-32 TERMINAL
(2 PLACES )
1.00
(25.4)
6-32 TERMINAL
(2 PLACES)
1.80
(45.7)
SOLID-STATE RELAY
OUTPUT
+
--
+
--
INPUT
MOUNTING
HOLE/SLOT
0.17 (4.3) DIA.
1
2
3
4
CURRENT DERATING CURVES
Crydom Heat Sinks
offer excellent
thermal management and are per-
fectly matched to the load current
ratings of Crydom panel mount
relays. Request Crydom's Heat Sink
specification sheet for all the details.
FastFax Document No. 163
SERIES DC60.
Rev. 021202
PAGE 2 OF 2
Series DC60
3-7Amp 60 Vdc DC Output
All dimensions are in inches
(millimeters)
Screw Torque Requirements:
6-32 Screws - 10 in. lbs.,
8-32 and 10-32 Screws - 20in. lbs.
(Screws dry without grease.)
AC CONTROL M ODELS
PIN 3: AC CONTROL
PIN 4: AC CONTROL
DC CONTROL M ODELS
PIN 3 : + DC CONTROL
PIN 4: -- DC CONTROL
SSR
INPUT
OUTPUT
4 1
(+)
3
2 (--)
()
(+)
LOAD
Input and output polarity must be observed.
Inductive loads must be diode suppressed.
Transient Protection
All loads are inductive, even ones that are not so labeled. An
inductive load will produce harmful transient voltages when it
is turned off. Diodes should be fast recovery type with PIV rated
greater than supply voltage.
2002 CRYDOM CORP, Specifications subject to change without notice.
For recommended applications and more information contact:
USA: Sales Support (877) 502-5500 Tech Support (877) 702-7700 FAX (619) 710-8540
Crydom Corp, 2320 Paseo de las Americas, Ste. 201, San Diego, CA 92154
Email: sales@crydom.com WEB SITE: http://www.crydom.com
UK: +44 (0)1202 365070 FAX +44 (0)1202 365090 Crydom International Ltd., 7 Cobham
Road, Ferndown Industrial Estate, Ferndown, Dorset BH21 7PE, Email: intsales@crydom.com.
GERMANY: +49 (0)180 3000 506