ChipFind - документация

Электронный компонент: GM123210GRNNB-01

Скачать:  PDF   ZIP
Confidential Document
Page: 2 /19
2. RECORD OF REVISION
Rev Date
Item
Page
Comment
B JAN/19/99
8,15
9,19
Correction pin definition on pin1 & 2.
Original
Pin1=VSS,
Pin2=VDD
Change to Pin1=VDD, Pin2=VSS.
C MAY/10/01 3,15,16 3,18,19
1. Change Outline Drawing.
2. Package Information.
D OCT/18/01 5,7
5,7
1. Change VDD from 4.7V~5.5V to
2.7V~ 5.5V.
JUL/16/02 13
17
Change: P/N from GM12322SRH-J2 to
GM123210GRNNB-01
Confidential Document
Page: 3 /19

3. GENERAL SPECIFICATION

Display Format :
122dots (W)
32dots (H)
Dot Size :
0.4 (W)
0.45 (H) mm
Dot Pitch
0.44 (W)
0.49 (H) mm
View Area :
60.6 (W)
20.0 (H) mm
General Dimensions :
64.8 (W)
30 (H)
4.7 (T) mm Max.
Weight :
10 g max.
V
LCD Type :
STN Gray
STN Yellow
FSTN
V
Polarizer mode :
Reflective
Transflective
Transmissive
Negative
V
View Angle :
6 O'clock
12 O'clock
Others
Backlight :
LED
EL
CCFL
Backlight Color :
Yellow green
Amber
Blue Green
White
Others
Controller / Driver :
SED1520D0A
Normal
V Wide Temperature
Operating 0 to 50
C Operating
-20 to 70
C
Temperature Range :
Storage -20 to 70
C Storage -30 to 80
C


Confidential Document
Page: 4 /19
4. ABSOLUTE MAXIMUM RATINGS

4.1 ELECTRICAL ABSOLUTE MAXIMUM RATINGS
V
SS
= 0V, Ta = 25
C
Item Symbol
Min.
Max.
Unit
Supply Voltage
(Logic)
V
DD
-V
SS
0
8
V
Supply Voltage
(LCD Driver)
V
DD
-V
EE
0
16.5 V
Input Voltage
V
I
V
SS-0.3
V
DD+0.3
V
Operating Temperature
T
OP
-20 70
C
Storage Temperature
T
STG
-30
80
C

4.2 ENVIRONMENTAL
ABSOLUTE MAXIMUM RATINGS
Operating Storage
Item
(Min.) Max.) (Min.) (Max.)
Comment
Ambient Temp
-20
70
-30
80
Note (1)
Humidity
Note (2)
Note(2)
Without Condensation
Vibration --
4.9M/S
2
-- 19.6M/S
2
XYZ
Direction
Shock --
29.4M/S
2
-- 490M/S
2
XYZ
Direction
Note(1) Ta =
0
C
: 50Hr Max.
Note(2) Ta
40C : 90% RH Max.
Ta 40C : Absolute humidity must be lower than the humidity
of 90% RH at 40
C
.



Confidential Document
Page: 5 /19

5. ELECTRICAL CHARACTERISTICS
Item Symbol
Condition
Min.
Typ.
Max.
Unit
Supply Voltage
(Logic)
V
DD
-V
SS
2.7
5.0 5.5 V
-20
C
6.9 7.5 8.1
25
C
5.8 6.4 6.9
Supply Voltage
(LCD)
V
DD
-V
EE
70
C
4.8 5.3 5.8
V
V
IH
V
SS+2.0
-- V
DD
Input Voltage
V
IL
--
V
SS
-- V
SS+0.8
V
Logic Supply
Current
I
DD
V
DD
-V
SS
=5V --
1.2
--
mA


6. ELECTRO-OPTICAL CHARACTERISTICS
ITEM Symbol
Condition
Min.
Typ.
Max.
Unit
Ref.
0
C
-- --
Rise Time
Tr
25
C
--
120 240
ms
0
C
-- --
Fall Time
Tf
25
C
--
200 350
ms
Note (1)
Contrast CR
25
C
3 4 --
Note
(3)
-- -- 80
View Angle
1
~
2
1,
2
25
C &
CR
1.5
-30 -- 30
Note
(2)
Frame Frequency
Ff
25
C
-- 64 -- Hz
Note (1) & (2) : See next page
Note (3) : Contrast ratio is defined under the following condition:

CR= Brightness of non-selected condition
Brightness of selected condition

( a ). Temperature ---------- 25
C
( b ). Frame frequency ---- 64Hz
( c ). Viewing angle --------
= 0
,
= 0
( d ). Operating voltage --- 6.4V
Confidential Document
Page: 6 /19


Note (1) Response time is measured as the shortest period of time possible
between the change in state of an LCD segment as demonstrated below:

+Vop

1/f F


0





-Vop


90%
100%
10%


t
r
t
f

Condition:
( a ) . Temperature ---------------25
C
( b ) . Frame frequency --------- 64Hz
( c ) . View Angle -----------------
= 0
,
=0
( d ) . Operating voltage -------- 6.4V


Note (2) Definition of View Angle

Top Bottom direction Right -- Left direction

Top
2
1
1

2



Bottom Left Right
Confidential Document
Page: 7 /19
7. TIMING CHARACTERISTICS
MPU Bus Read/Write II (68 family MPU)
t
CYC6
E
t
EW
t
AW6
t
DS6
R/W
t
AH6
A0,CS
t
DH6
D0 to D7
(WRITE)
t
ACC6
t
OH6
D0 to D7
(READ)
Ta = -20 to 75 C, VSS = -5.0V 10% unless stated otherwise
Rating
Parameter Symbol
Condition
min max
Unit Signal
System cycle time
t
CYC6
1000
--
ns
Address setup time
t
AW6
20
--
ns
Address hold time
t
AH6
10
--
ns
A0,CS,
R/W
Data setup time
t
DS6
80
--
ns
Data hold time
t
DH6
10
--
ns
Output disable time
t
OH6
10
60
ns
Access time
t
ACC6
CL = 100 PF
-- 90 ns
Read
100
ns
D0 to D7
Enable
Pulse width Write
t
EW
8
ns
E
Rise and fall time
t
r,
t
f
15
ns

(VSS=-2.7 to -4.5V Ta = -20 to 75 C
Rating
Parameter Symbol
Condition
min max
Unit Signal
System cycle time
t
CYC6
2000
--
ns
Address setup time
t
AW6
40
--
ns
Address hold time
t
AH6
20 -- ns
A0,CS,
R/W
Data setup time
t
DS6
160
--
ns
Data hold time
t
DH6
20 -- ns
Output disable time
t
OH6
20
120
ns
Access time
t
ACC6
CL = 100 PF
-- 180 ns
D0 to D7
Read 200
--
ns
Enable
Pulse width Write
t
EW
160 --
ns
E
Rise and fall time
t
r,
t
f
15
ns
Notes :
1. t
CYC6
is the cycle time of CS. E = H, not the cycle time of E.
Confidential Document
Page: 8 /19
8. PIN CONNECTIONS


No. Symbol
Function
1
VDD
Logic power supply ( 5V )
2
VSS
Power supply ( 0V, GND )
3
V0
Power supply for LCD drive
4
/RES
Reset function ( Active Low )
5
E1
Read/Write Enable Signal (Master)
6
E2
Read/Write Enable Signal (Salve)
7
R/W
Read/Write Select Signal
8
AO
Selects Display Data (H) or Instructions (L)
9-16
DB0-DB7 Data Bus Line
17
LED A
LED Anode (Power supply +)
18
LED K
LED Cathode (Power supply -)



9. POWER SUPPLY

VDD
+5V VSS LCM
VR V0
-5V
VR = 10K
LEDA (5V) R8 A LED B/L
R9
LEDK (GND) K

R8 & R9 = 51 OHM
Confidential Document
Page: 9 /19

10. BLOCK DIAGRAM

VSS
61Seg
( seg 0 60 )
VDD
V0 SED1520
A0
16Com
E1
R/W
/RES
E2
16Com
SED1520
DB0
LCD PANEL
122
32 DOTS
DB7
61Seg ( seg 0 60 )




Confidential Document
Page: 10 /19

Page
address
Data
Line
address
Associated
line (ex)
Common
output
D0
00H
COM 0
D1
01H
1
D2
02H
2
D3
03H
3
D4
04H
4
D5
05H
5
D6
06H
6
D1, D2
=
0,0
D7
Page
0
07H
Start
7
D0
08H
8
0,1
D7
Page
1
0FH
15
D0
10H
16
1,0
D7
Page
2
17H
1/16
23
D0
18H
24
1,1
D7
Page
3
1FH
31
D0=0 00H 01H 02H 03H
4FH
Map
ADC
D0=1 4FH 4EH 4DH 4CH
00H
Note : indicates the display area.
SEG
pin SEG0 SEG1 SEG2 SEG3
SEG79
Column
address
Display Data RAM Addressing
Confidential Document
Page: 11 /19



COMMANDS
Summary
Code Function
Command
A0 RD WR D7 D6 D5 D4 D3 D2 D1 D0
Display
ON/OFF
0 1 0 1 0 1 0 1 1 1 0/1
Turns display on or off.
1 : ON, 0 : OFF
Display start line
0
1
0
1
1
0
Display start address (0 to 31)
Specifies RAM line corresponding
to top line of display.
Set page address
0
1
0
1
0
1
1
1
0
Page (0 to 3)
Sets display RAM page in page
address register.
Set column
(segment) address
0
1
0
0
Column address (0 to 72)
Sets display RAM column address
in column address register.
Reads the following status:
BUSY
1 : Busy
0 : Ready
ADC
1 : CW output
0 : CCW output
ON/OFF
1 : Display off
0 : Display on
Read status
0
0
1
Busy ADC ON/OFF
Reset
0 0 0 0
RESET
1 : Being reset
0 : Normal
Write display data
1
1
0
Write data
Writes data from data bus into
display RAM.
Read display data
1
0
1
Read data
Reads data from display RAM
onto data bus.
Select
ADC
0 1 0 1 0 1 0 0 0 0 0/1
0 : CW output
1 : CCW output
Static drive
ON/OFF
0 1 0 1 0 1 0 0 1 0 0/1
Selets static driving operation.
1 : Static drive
0 : Normal driving
Select
duty
0 1 0 1 0 1 0 1 0 0 0/1
Selets LCD duty cycle
1 : 1/32
0 : 1/16
Read Modify - Write
0
1
0
1
1
1
0
0
0
0
0
Read modify write ON
End
0
1
0
1
1
1
0
1
1
1
0
Read modify write OFF
Reset
0 1 0 1 1 1 0 0 0 1 0 Software
reset

Confidential Document
Page: 12 / 19

11. QUALITY ASSURANCE
11.1 Test Condition
11.1.1 Temperature and Humidity(Ambient Temperature)
Temperature : 20
5
C
Humidity : 65
5%
11.1.2 Operation
Unless specified otherwise, test will be conducted with LCM in
operation.
11.1.3 Container
Unless specified otherwise, vibration test will be conducted on
module only.
11.1.4 Test Frequency
Single cycle.
11.1.5 Test Method
No. Parameter
Conditions Regulations
1 High Temperature Operating
70
2
C
Note 3
2 Low Temperature Operating
-20
2
C
Note 3
3 High Temperature Storage
80
2
C
Note 3
4 Low Temperature Storage
-30
2
C
Note 3
5
Vibration Test
(Non-operation state)
Total fixed amplitude : 1.5mm
Vibration Frequency : 10 ~ 55Hz
One cycle 60 seconds to 3 directions
of X.Y.Z. for each 15 minutes
Note 3
6
Damp Proof Test
(Non-operation state)
40
C
2
C, 90~95%RH, 96h
Note 1,2
7
Shock Test
(Non-operation state)
To be measured after dropping from
60cm high once concrete surface in
packing state
Note 3
Note 1: Returned under normal temperature and humidity for 4 hrs.
Note 2: No dew condensation to be observed.
Note 3: No change on display and in operation under the test condition



Confidential Document
Page: 13 / 19
11.2 Inspection condition

11.2.1 Inspection conditions
The LCD shall be inspected under 40W white fluorescent light.




45









11.2.2 Definition of applicable Zones



B
LCD
A
BEZEL

PCB




A : Display Area
B : Non-Display Area

Confidential Document
Page: 14 / 19
11.2.3 Inspection Parameters
No. Parameter Criteria

1
Black or White spots
Acceptable
number
Zone

Dimension
A B
Class
Of
Defects
AQL
Level
D < 0.15
0.15
D< 0.2
4 4
0.2
D
0.25
2 2
D
0.3
0 1
Minor 2.5
D = (Long + Short) / 2 * : Disregard
2
Scratch, Substances
Acceptable
number


X (mm)
Zone

Y(mm)
A B
Class
Of
Defects
AQL
Level
0.04
W
3.0
L 0.06
W
4 4
2.0
L 0.08
W
2 3
0.1
<
W
0 1
Minor 2.5
X : Length Y : Width
: Disregard
Total defects should not exceed 4/module

3
Air Bubbles
(between glass
& polarizer)
Acceptable
number
Zone

Dimension
A B
Class
of
Defects
AQL
Level
D
0.15
0.15
<
D
0.25
2
0.25
<
D
0 1
Minor 2.5
: Disregard

Total defects shall not excess 3/module.




Confidential Document
Page: 15 / 19
3
Uniformity of Pixel

(1) Pixel shape (with Dent)
0.152








(2) Pixel shape ( with Projection)



Should not be connected to
next pixel


0.152

(3) Pin hole
X

Y
( X + Y )/2
0.02mm

(Less than 0.1 mm is no counted)


(4) Deformation



X ( X + Y ) / 2
0.3mm





Y
Total acceptable number : 1/pixel, 5/cell
Confidential Document
Page: 16 / 19
12. LOT NUMBERING SYSTEM
9 7 4 2


Production week number
Production year
13. LCM NUMBERING SYSTEM
GM 123210 G R N N B 01

VERSION :01
View direction & Temp. Range
ABottom view 6H & Normal temp.
BBottom view 6H & Wide temp.
CTop View & Normal temp.
DTop View & Wide temp.
Backlight Color
B Blue
W White
N None
Backlight
S edge light LED B/L
E EL
N No Back light
MODE
M transmissive R Reflective
F transflective N - Negative
LCD type
G STN
Gray
S STN
Yellow
N TN
Series code
123210
122 Dots X 32Dot, 1 LCD type,0 PCB type

Model type
CM Character Module
GM Graphic Module
CX Custom Character Module
GX Custom Graphic Module
Confidential Document
Page: 17 / 19
14. PRECAUTION FOR USING LCM












































1. LIQUID CRYSTAL DISPLAY (LCD)
LCD is made up of glass, organic sealant, organic fluid, and
polymer based polarizers. The following precautions should
be taken when handing,
(1). Keep the temperature within range of use and storage.
Excessive temperature and humidity could cause
polarization degredation, polarizer peel off or bubble.
(2). Do not contact the exposed polarizers with anything
harder than an HB pencil lead. To clean dust off the
display surface, wipe gently with cotton, chamois or other
soft material soaked in petroleum benzin.
(3). Wipe off saliva or water drops immediately. Contact
with water over a long period of time may cause polarizer
deformation or color fading, while an active LCD with
water condensation on its surface will cause corrosion of
ITO electrodes.
(4). Glass can be easily chipped or cracked from rough
handling, especially at corners and edges.
(5). Do not drive LCD with DC voltage.

2. Liquid Crystal Display Modules
2.1 Mechanical Considerations
LCM are assembled and adjusted with a high degree of
precision. Avoid excessive shocks and do not make any
alterations or modifications. The following should be noted.
(1). Do not tamper in any way with the tabs on the metal
frame.
(2). Do not modify the PCB by drilling extra holes,
changing its outline, moving its components or modifying
its pattern.
(3). Do not touch the elastomer connector, especially
insert an backlight panel (for example, EL).
(4). When mounting a LCM make sure that the PCB is not
under any stress such as bending or twisting . Elastomer
contacts are very delicate and missing pixels could result
from slight dislocation of any of the elements.
(5). Avoid pressing on the metal bezel, otherwise the
elastomer connector could be deformed and lose contact,
resulting in missing pixels.

2.2. Static
Electricity
LCM contains CMOS LSI's and the same precaution for
such devices should apply, namely
(1). The operator should be grounded whenever he/she
comes into contact with the module. Never touch any of the
conductive parts such as the LSI pads, the copper leads on
the PCB and the interface terminals with any parts of the
human body.
(2). The modules should be kept in antistatic bags or other
containers resistant to static for storage.
(3). Only properly grounded soldering irons should be
used.
(4). If an electric screwdriver is used, it should be well
grounded and shielded from commutator sparks.


(5) The normal static prevention measures should be
observed for work clothes and working benches; for the
latter conductive (rubber) mat is recommended.
(6). Since dry air is inductive to statics, a relative
humidity of 50-60% is recommended.

2.3 Soldering
(1). Solder only to the I/O terminals.
(2). Use only soldering irons with proper grounding
and no leakage.
(3). Soldering temperature : 280
C 10C
(4). Soldering time: 3 to 4 sec.
(5). Use eutectic solder with resin flux fill.
(6). If flux is used, the LCD surface should be covered
to avoid flux spatters. Flux residue should be removed
after wards.

2.4 Operation
(1). The viewing angle can be adjusted by varying the
LCD driving voltage V0.
(2). Driving voltage should be kept within specified
range; excess voltage shortens display life.
(3). Response time increases with decrease in
temperature.
(4). Display may turn black or dark blue at
temperatures above its operational range; this is
(however not pressing on the viewing area) may cause
the segments to appear "fractured".
(5). Mechanical disturbance during operation (such as
pressing on the viewing area) may cause the segments to
appear "fractured".

2.5 Storage
If any fluid leaks out of a damaged glass cell, wash off
any human part that comes into contact with soap and
water. Never swallow the fluid. The toxicity is extremely
low but caution should be exercised at all the time.

2.6 Limited Warranty
Unless otherwise agreed between DATA IMAGE and
customer, DATA IMAGE will replace or repair any of its
LCD and LCM which is found to be defective
electrically and visually when inspected in accordance
with DATA IMAGE acceptance standards, for a period
on one year from date of shipment. Confirmation of such
date shall be based on freight documents. The
warranty liability of DATA IMAGE is limited to repair
and/or replacement on the terms set forth above. DATA
IMAGE will not responsible for any subsequent or
consequential events.



Confidential Document
Page: 18 / 19
15 OUTLINE DRAWING
Confidential Document
Page: 19 / 19
Anti-static Bag
Module
16. PACKAGE INFORMATION