ChipFind - документация

Электронный компонент: H12D4825DE

Скачать:  PDF   ZIP
M O D E L N U M B E R S
D2425D
D2440D
H12D4825D
H12D4840D
OUTPUT SPECIFICATIONS
Operating Voltage (47-63 Hz) [Vrms]
24-280
24-280
48-530
48-530
Load Current Range
[Arms]
.15-25
.15-40
.15-25
.15-40
Transient Overvoltage [Vpk]
600
600
1200
1200
Max. Surge Current, (16.6ms) [Apk]
250
625
250
625
Max. On-State Voltage Drop @ Rated Current [Vpk]
1.6
1.6
1.6
1.6
Thermal Resistance Junction to Case (R
JC) [C/W]
1.02
.63
1.02
.63
Maximum I2 t for Fusing, (8.3 msec.) [A2sec]
260
1620
260
1620
Max. Off-State Leakage Current @ Rated Voltage [mArms]
10
10
10
10
Min. Off-State dv/dt @ Max. Rated Voltage [V/sec]
500
500
500
500
Max. Turn-On Time
1/2 cycle
1/2 cycle
1/2 cycle
1/2 cycle
Max. Turn-Off Time
1/2 cycle
1/2 cycle
1/2 cycle
1/2 cycle
Power Factor (Min.) with Max. Load
0.5
0.5
0.5
0.5
INPUT SPECIFICATIONS
H12D48XXD
Control Voltage Range
4-15Vdc
Max. Turn-On Voltage
4.0 Vdc
Min. Turn-Off Voltage
1.0 Vdc
Nominal Input Impedance
240 Ohms
Typical Input Current @ 5Vdc (@ 24Vdc for E-Suffix)
13mA
GENERAL NOTES
All parameters at 25C and per section unless otherwise specified.
Off-State dv/dt test method per EIA/NARM standard RS-443, paragraph 13.11.1
Heat sinking required, for derating curves see page 2.
Turn-on time for random turn-on (-10) versions is 0.1 msec.
Zero Voltage and Random
Turn-On Swi tching
SCR Output
Industry Standard Package
Panel M ount
FastFax Document No. 165
DUAL.
Rev. 111203
PAGE 1 OF 2
Two totally independent AC output
relays come in a single standard panel-
mount package. Utilizing an AC switch
output with internal snubber, relays
provide greater protection against false
triggering. Model choices include zero-
voltage or random turn-on (phase con-
trollable) switching.
Manufactured in Crydom's ISO 9001
Certified facility for optimum product
performance and reliability.
Crydom Heat Sinks
offer excellent thermal
management and are perfectly matched to the
load current ratings of Crydom panel mount
relays. Request Crydom's Heat Sink specifica-
tion sheet for all the details.
2003 CRYDOM CORP, Specifications subject to change without notice.
D2425DE
D2440DE
H12D4825DE
H12D4840DE
E-SUFFIX
15-32Vdc
15 Vdc
1.0 Vdc
1500 Ohms
15mA
D24XXD
4-15Vdc
4.0 Vdc
1.0 Vdc
300 Ohms
13mA
For recommended applications and more information contact:
USA: Sales Support (877) 502-5500 Tech Support (877) 702-7700 FAX (619) 710-8540
Crydom Corp, 2320 Paseo de las Americas, Ste. 201, San Diego, CA 92154
Email: sales@crydom.com WEB SITE: http://www.crydom.com
UK: +44 (0)1202 365070 FAX +44 (0)1202 365090 Crydom International Ltd., 7 Cobham
Road, Ferndown Industrial Estate, Ferndown, Dorset BH21 7PE, Email: intsales@crydom.com.
GERMANY: +49 (0)180 3000 506
D
ual
R
elays
25-40A
mp
120/240, 480 V
ac
AC OUTPUT
All dimensions are in inches (millimeters)
CURRENT DERATING CURVES
120/240 V MO DEL
480V MO DEL
AVAILABLE OPTIONS
-10
Random Turn-On,
Phase Controllable
GENERAL SPECIFICATIONS
Dielectric Strength50/60Hz Input/Output/Base
4000 Vrms
Insulation Resistance (Min.) @ 500 Vdc
10
9
Ohm
Max. Capacitance Input/Output
10 pF
Ambient Operating Temperature Range
-40 to 80C
Ambient Storage Temperature Range
-40 to 125C
M ECHANICAL SPECIFICATIONS
Weight: (typical)
3.0 oz. (86.5g)
Encapsulation: Thermally
Conductive
Epoxy
Terminals:
.25' Fastons, .025' Square Pins
APPROVALS
UL
E116949
CSA LR81689 (240V only)
VDE 5902 UG
FastFax Document No. 165
DUAL.
Rev. 111203
PAGE 2 OF 2
2003 CRYDOM CORP, Specifications subject to change without notice.
E
15-32Vdc Control
Example:
H12D4840DE
1.87
(47.5)
.85
(21.6)
1.31
(33.2)
1.00
(25.4)
1.17
(29.7)
FASTON
TERMINAL
.250 X .032
(4 PLACES)
PIN .025 SQ.
.100 CENTERS
4 PLACES
MOUNTING
HOLE/SLOT
0.17 (4.3) DIA.
4-15VDC
CONTROL
B
CONTROL
A
4-15VDC
CONTROL
B
CONTROL
A
A1
A2
B1
B2
120/24OV - 20A
120/24OV - 20A
.85
(21.6)
1.31
(33.2)
.15
(3.8)
.50
(12.7)
.45
(11.4)
.55
(14.0)
2.30
(58.4)
1.80
(45.7)
.77
(19.6)
1.37
(34.8)
1.87
(47.5)
1.60
(40.6)
MOUNTING HOLE/SLOT
.017 (4.3) DIA.
2 PLC'S
A1 A2
120/24OV - 20A
120/24OV - 20A
B1 B2
1.80
2.30
(58.4)
-
+
-
+
.250 X .032 FASTON
TERMINAL
(4 PLACES)
.187 X .032
FASTON
TERMINAL
(4 PLACES)
40
20
0
20
10
30
50
40
10
20
30
40
50
60
70
80
Load Current [Arms]
Max Ambient Temp. [C]
Max Allowable Base Temp. [

C]
Power Dissipation [W]
25A LIMIT
(1 SECTION)
50A LIMIT
(2 SECTIONS)
95
105
75
85
0.5C/W
1.0C/W
2.0C/W
5.0C/W
240V Model
B1
LOAD B
B2
A2
A1
120/240Vrms
120/240Vrms
-- B CONTROL
+ B CONTROL
-- A CONTROL
+ A CONTROL
LOAD A
100
80
60
40
20
0
40
20
60
100
80
10
20
30
40
50
60
70
80
Load Current [Arms]
Max Ambient Temp. [C]
Max Allowable Base Temp. [

C]
Power Dissipation [W]
40A LIMIT
(1 SECTION)
80A LIMIT
(2 SECTIONS)
100
105
90
95
1.0C/W
2.0C/W
5.0C/W
0.5C/W
480V Model
B1
LOAD B
B2
A2
A1
480Vrms
480Vrms
+ B CONTROL
-- B CONTROL
LOAD A
-- A CONTROL
+ A CONTROL
W IRING DIAGRAM S
25A
40A
Example:
D2440D-10
For recommended applications and more information contact:
USA: Sales Support (877) 502-5500 Tech Support (877) 702-7700 FAX (619) 710-8540
Crydom Corp, 2320 Paseo de las Americas, Ste. 201, San Diego, CA 92154
Email: sales@crydom.com WEB SITE: http://www.crydom.com
UK: +44 (0)1202 365070 FAX +44 (0)1202 365090 Crydom International Ltd., 7 Cobham
Road, Ferndown Industrial Estate, Ferndown, Dorset BH21 7PE, Email: intsales@crydom.com.
GERMANY: +49 (0)180 3000 506
H
Heat Transfer Pad (Attached)
Example:
D2440DH
D
ual
R
elays
25-40A
mp
120/240, 480 V
ac
AC OUTPUT