ChipFind - документация

Электронный компонент: HIH-3610-003

Скачать:  PDF   ZIP

Humidity Sensors
Humidity Sensor
HIH-3610 Series
Sensing and Control
FEATURES
Molded thermoset plastic
housing with cover
Linear voltage output vs
%RH
Laser trimmed
interchangeability
Low power design
High accuracy
Fast response time
Stable, low drift
performance
Chemically resistant

TYPICAL APPLICATIONS
Refrigeration
Drying
Metrology
Battery-powered systems
OEM assemblies
The HIH-3610 Series humidity sensor is designed specifically for high
volume OEM (Original Equipment Manufacturer) users. Direct input to a
controller or other device is made possible by this sensor's linear voltage
output. With a typical current draw of only 200
A, the HIH-3610 Series is
ideally suited for low drain, battery operated systems. Tight sensor
interchangeability reduces or eliminates OEM production calibration costs.
Individual sensor calibration data is available.
The HIH-3610 Series delivers instrumentation-quality RH (Relative
Humidity) sensing performance in a low cost, solderable SIP (Single In-line
Package). Available in two lead spacing configurations, the RH sensor is a
laser trimmed thermoset polymer capacitive sensing element with on-chip
integrated signal conditioning. The sensing element's multilayer
construction provides excellent resistance to application hazards such as
wetting, dust, dirt, oils, and common environmental chemicals.
WARNING
PERSONAL INJURY
DO NOT USE these products as safety or emergency stop devices, or in
any other application where failure of the product could result in personal
injury.
Failure to comply with these instructions could result in death or
serious injury.
WARNING
MISUSE OF DOCUMENTATION
The information presented in this product sheet is for reference only. Do
not use this document as system installation information
Complete installation, operation, and maintenance information is
provided in the instructions supplied with each product.
Failure to comply with these instructions could result in death or
serious injury.
Humidity Sensors
Humidity Sensor
HIH-3610 Series
2 Honeywell
Sensing and Control
For application help: call 1-800-537-6945
TABLE 1: PERFORMANCE SPECIFICATIONS
Parameter
Condition
RH Accuracy
(1)
2% RH, 0-100% RH non-condensing, 25 C, V
supply
= 5 Vdc
RH Interchangeability
5% RH, 0-60% RH; 8% @ 90% RH typical
RH Linearity
0.5% RH typical
RH Hysteresis
1.2% RH span maximum
RH Repeatability
0.5% RH
RH Response Time, 1/e
15 sec in slowly moving air at 25 C
RH Stability
1% RH typical at 50% RH in 5 years
Power Requirements
Voltage Supply
Current Supply

4 Vdc to 5.8 Vdc, sensor calibrated at 5 Vdc
200
A at 5 Vdc
Voltage Output

V
supply
= 5 Vdc
Drive Limits
V
out
= V
supply
(0.0062(Sensor RH) + 0.16), typical @ 25
C
(Data printout option provides a similar, but sensor specific, equation at 25
C.)
0.8 Vdc to 3.9 Vdc output @ 25
C typical
Push/pull symmetric; 50
A typical, 20
A minimum, 100
A maximum
Turn-on
0.1 sec
Temperature Compensation

Effect @ 0% RH
Effect @ 100% RH
True RH = (Sensor RH)/(1.093-0.0021T), T in F
True RH = (Sensor RH)/(1.0546-0.00216T), T in
C
0.007 %RH/C (negligible)
-0.22% RH/C (<1% RH effect typical in occupied space systems above 15 C (59
F))
Humidity Range
Operating
Storage

0 to 100% RH, non-condensing
(1)
0 to 90% RH, non-condensing
Temperature Range
Operating
Storage

-40 C to 85 C (-40
F to 185
F)
-51 C to 125 C (-60
F to 257
F)
Package
(2)
Three pin, solderable SIP in molded thermoset plastic housing with thermoplastic
cover
Handling
Static sensitive diode protected to 15 kV maximum
Notes:
1. Extended exposure to
90% RH causes a reversible shift of 3% RH.
2. This sensor is light sensitive. For best results, shield the sensor from bright light.







Humidity/Moisture Sensors
Humidity Sensor
HIH-3610 Series
For application help: call 1-800-537-6945
Honeywell
Sensing and Control 3
FACTORY CALIBRATION
HIH-3610 sensors may be ordered with a
calibration and data printout (Table 2). See order
guide on back page.
TABLE 2: EXAMPLE DATA PRINTOUT
Model
HIH-3610-001
Channel
92
Wafer
030996M
MRP
337313
Calculated values at 5 V
V
out
@ 0% RH
V
out
@ 75.3% RH

0.958 V
3.268 V
Linear output for 2% RH
accuracy @ 25 C
Zero offset
Slope
RH


0.958 V
30.680 mV/%RH
(V
out
-zero offset)/slope
(V
out
-0.958)/0.0307
Ratiometric response for 0
to 100% RH
V
out


V
supply
(0.1915 to 0.8130)

FIGURE 1: RH SENSOR CONSTRUCTION
SUBSTRATE (SILICON)
PLATINUM LAYER
POROUS PLATINUM LAYER
THERMOSET POLYMER
THERMOSET
POLYMER
DIRT, DUST AND OILS DO NOT AFFECT SENSOR
FIGURE 2: OUTPUT VOLTAGE VS RELATIVE
HUMIDITY AT 0 C
0.0
0.5
1.0
1.5
2.0
2.5
3.0
3.5
4.0
4.5
20
40
60
80 100
Output Voltage (Vdc)
Sensor Response
Best Linear Fit
4.07
0.8
Relative Humidity (%)
0

FIGURE 3: OUTPUT VOLTAGE VS RELATIVE
HUMIDITY AT 0 C, 25 C, 85 C
0.0
0.5
1.0
1.5
2.0
2.5
3.0
3.5
4.0
4.5
20
40 60
80 100
Output Voltage (Vdc)
4.07
0.8
Relative Humidity (%)
3.90
3.50
0

Humidity/Moisture Sensors
Humidity Sensor
HIH-3610 Series
Sensing and Control
Honeywell
11 West Spring Street
Freeport, Illinois 61032
Printed with Soy Ink
on 50% Recycled Paper
009012-2-EN IL50 GLO 501 Printed in USA
www.honeywell.com/sensing
ORDER GUIDE
Catalog Listing
Description
HIH-3610-001
Integrated circuit humidity sensor, 0.100 in lead
pitch SIP
HIH-3610-002
Integrated circuit humidity sensor, 0.050 in lead
pitch SIP
HIH-3610-003
Integrated circuit humidity sensor, 0.100 in lead
pitch SIP with calibration and data printout
HIH-3610-004
Integrated circuit humidity sensor, 0.050 in lead
pitch SIP with calibration and data printout

FIGURE 4: MOUNTING DIMENSIONS (for reference only) mm (in)
12,70 MIN
(0.50)
9,47
(0.373)
1,27
(0.050)
2,54
(0.100)
3X 0,38
(0.015)
4,27
(0.168)
-
OUT
+
OUT
-
+
4,27
(0.168)
2,54
(0.100)
5,08
(0.200)
12,19 MIN
(0.480)
1,90
(0.075)
9,47
(0.373)
2,03
(0.080)
3X 0,38
(0.015)
HIH-3610-001
HIH-3610-003
HIH-3610-002
HIH-3610-004
WARRANTY/REMEDY
Honeywell warrants goods of its
manufacture as being free of defective
materials and faulty workmanship.
Contact your local sales office for
warranty information. If warranted
goods are returned to Honeywell
during the period of coverage,
Honeywell will repair or replace
without charge those items it finds
defective. The foregoing is Buyer's
sole remedy and is in lieu of all other
warranties, expressed or implied,
including those of merchantability
and fitness for a particular
purpose.
Specifications may change without
notice. The information we supply is
believed to be accurate and reliable
as of this printing. However, we
assume no responsibility for its use.
While we provide application
assistance personally, through our
literature and the Honeywell web site,
it is up to the customer to determine
the suitability of the product in the
application.
For application assistance, current
specifications, or name of the nearest
Authorized Distributor, check the
Honeywell web site or call:
1-800-537-6945 USA
1-800-737-3360 Canada
1-815-235-6847 International
FAX
1-815-235-6545 USA
INTERNET
www.honeywell.com/sensing
info.sc@honeywell.com