10/15 Watts
WU Series
4:1 Input Range
Isolated Outputs
Efficiency to 84%
Overvoltage Protection
Input
Filter
Short Circuit Protected
Fully Regulated Outputs
Specification
I
ntelligent Design
Q
uality Product
XPiQ inc.
DC/DC Converters
Input
Input Voltage Range
See Table
Input Filter
Network
Output
Voltage Accuracy
1.0% max.
Line Regulation
1.0% max.
(Full Input Range)
Load Regulation
1.0% max.
(1/4-full load)
Ripple & Noise
1% of Vout max.
(DC-20 MHz)
Temperature
0.02%/C max.
Coefficient
Short Circuit
Indefinite
Protection
General
Switching
100
kHz
Frequency
Efficiency
See Table
Isolation
500 VDC
(Input-Output)
(1000 Mohm/80pF)
Environmental
Operating
-25C to +71C
Temperature
Storage
-55C to 125C
Temperature
All specifications are typical at nominal line, full load and 25C
PH: 508 429.9883
FAX: 800 226.2100
Email: sales@xp-iq.com
Holliston, MA 01746 USA
www.
XP-iQ
.com
25
Mechanical Details
Logic Compatibility ................CMOS or Open Collector TTL
Ec - ON,........................................>+5.5 VDC or Open Circuit
Ec - OFF, ..................................................................<1.8 VDC
Shutdown Idle Current ..................................................10 mA
Input Resistance ......................(Ein 0 VDC to 9 VDC)100KOhm
Control Common ........................Referenced to input Minus
REMOTE ON/OFF CONTROL
Output may optionally be externally trimmed (5%)
with a fixed resistor or an external trimpot as shown.
EXTERNAL OUTPUT TRIMMING
PIN
SINGLE
DUAL
TRIPLE
1
+ Input
+ Input
Disable
2
- Input
- Input
- Input
3
+ Output
+ Output
+ Input
4
Trim
Common
- Output
5
- Output
- Output
Common
6
Disable
Disable
5 VDC Output
7
-
-
+ Output
NOTES:
1. Voltage accuracy on 3VDC and triple outputs 3% Max.
Single outputs can be trimmed 5%.
2. Load regulation 2% for dual and triple outputs.
3. Triple outputs require minimum of 10% load for rated performance.
4. Remote on/off standard on triple output units, add
suffix "E" to part number for option on single and dual output units.
SINGLE/DUAL OUTPUT
TRIPLE OUTPUT
OUTPUT VOLTAGE & CURRENT RATINGS
WU
Model
Input Output Output
Input
Current
%
Voltage
Voltage
Current
No Load
Full Load
Efficiency
WU100
4.5-6.0 VDC
3.3 VDC
3000 mA
10 mA
2470 mA
80
WU101
4.5-6.0 VDC
5.0 VDC
2000 mA
10 mA
2620 mA
76
WU102
4.5-6.0 VDC
12.0 VDC
800 mA
10 mA
2520 mA
76
WU103
4.5-6.0 VDC
15.0 VDC
667 mA
10 mA
2510 mA
80
WU104
4.5-6.0 VDC
5.0 VDC
1000 mA
10 mA
2620 mA
76
WU105
4.5-6.0 VDC
12.0 VDC
400 mA
10 mA
2520 mA
76
WU106
4.5-6.0 VDC
15.0 VDC
333 mA
10 mA
2510 mA
79
WU200
9.0-18.0 VDC
3.3 VDC
3000 mA
10 mA
1030 mA
80
WU201
9.0-36.0 VDC
5.0 VDC
3000 mA
30 mA
1560 mA
80
WU202
9.0-36.0 VDC
12.0 VDC
1250 mA
30 mA
1540 mA
81
WU203
9.0-36.0 VDC
15.0 VDC
1000 mA
30 mA
1525 mA
82
WU204
9.0-36.0 VDC
5.0 VDC
1500 mA
30 mA
1560 mA
80
WU205
9.0-36.0 VDC
12.0 VDC
625 mA
30 mA
1540 mA
81
WU206
9.0-36.0 VDC
15.0 VDC
500 mA
30 mA
1520 mA
82
WU207
9.0-36.0 VDC
5.0/12.0 VDC
1500/310 mA
20 mA
1576 mA
79
WU208
9.0-36.0 VDC
5.0/15 VDC
1500/250 mA
20 mA
1582 mA
79
WU209
9.0-36.0 VDC
5.0/+12.0/5.0 VDC 1500/310/500 mA
20 mA
1447 mA
79
WU300
18.0-36.0 VDC
3.3 VDC
3000 mA
10 mA
500 mA
83
WU301
20.0-72.0 VDC
5.0 VDC
3000 mA
20 mA
760 mA
82
WU302
20.0-72.0 VDC
12.0 VDC
1250 mA
20 mA
750 mA
83
WU303
20.0-72.0 VDC
15.0 VDC
1000 mA
20 mA
745 mA
84
WU304
20.0-72.0 VDC
5.0 VDC
1500 mA
20 mA
760 mA
82
WU305
20.0-72.0 VDC
12.0 VDC
625 mA
20 mA
750 mA
83
WU306
20.0-72.0 VDC
15.0 VDC
500 mA
20 mA
745 mA
84
WU307
20.0-72.0 VDC
5.0/12.0 VDC
1500/310 mA
15 mA
778 mA
80
WU308
20.0-72.0 VDC
5.0/15.0 VDC
1500/250 mA
15 mA
781 mA
80
WU309
20.0-72.0 VDC
5.0/+12.0/5.0 VDC 1500/310/500 mA
15 mA
715 mA
80
WU400
36.0-72.0 VDC
3.3 VDC
3000 mA
10 mA
245 mA
84