ChipFind - документация

Электронный компонент: XR16C2850IJ

Скачать:  PDF   ZIP
EXAR Corporation, 48720 Kato Road, Fremont, CA 94538
(510) 668-7000
FAX (510) 668-7017
XR16C2850
Rev. 1.00P
PLCC Package
DUAL UART WITH 128-byte FIFOs AND
RS-485 HALF DUPLEX CONTROL
DESCRIPTION
The XR16C2850 (2850) is a dual universal asynchronous receiver and transmitter (UART). The 2850 provides
enhanced UART functions with 128 byte FIFO, automatic RS-485 half duplex control, a modem control interface,
and data rates up to 1.5 Mbps. Onboard status registers provide the user with error indications and operational
status. System interrupts and modem control features may be tailored by external software to meet specific user
requirements. An internal loopback capability allows onboard diagnostics. Independent programmable baud rate
generators are provided to select transmit and receive clock rates up to 1.5 Mbps. The baud rate generator can
be configured for either crystal or external clock input. The 2850 is available in a 40-pin PDIP, 44-pin PLCC, and
48-pin TQFP packages. The 40 pin package does not offer TXRDY and RXRDY pins (DMA Signal monitoring).
Otherwise the three package versions are the same. The 2850 is functionally compatible with the ST16C2550.
The 2850 is fabricated in an advanced CMOS process to achieve low drain power and high speed requirements.
FEATURES
Pin and functionally compatible to ST16C2550,
software compatible with INS8250, NS16C550
1.5 Mbps transmit/receive operation (24 MHz
Max.).
128 byte transmit FIFO to reduce bandwidth re-
quirement of the external CPU.
128 byte receive FIFO with error flags to reduce
bandwidth requirement of the external CPU.
Independent transmit and receive UART control.
RS-485 half duplex control.
Programmable transmit/receive FIFO trigger lev-
els.
Hardware / software flow control.
Selectable RTS flow control hysterisis.
Modem control signals (-CTS, -RTS, -DSR, -DTR,
-RI, -CD, and software controllable line break).
Programmable character lengths (5, 6, 7, 8) with
even, odd, or no parity.
Infrared receive and transmit encoder/decoder.
Device identification.
Crystal or external clock input.
460.8 Kbps transmit/receive operation with 7.3728
MHz crystal or external clock source.
ORDERING INFORMATION
Part number
Pins Package
Operating temperature
XR16C2850CP
40 PDIP
0 C to + 70 C
XR16C2850CJ
44 PLCC
0 C to + 70 C
XR16C2850CM
48 TQFP
0 C to + 70 C
Part number
Pins Package
Operating temperature
XR16C2850IP
40 PDIP
-40 C to + 85 C
XR16C2850IJ
44 PLCC
-40 C to + 85 C
XR16C2850IM
48 TQFP
-40 C to + 85 C
6
5
4
3
2
1
44
43
42
41
40
7
8
9
10
11
12
13
14
15
16
17
39
38
37
36
35
34
33
32
31
30
29
18
19
20
21
22
23
24
25
26
27
28
D5
D6
D7
RXB
RXA
-TXRDYB
TXA
TXB
-OPB
-CSA
-CSB
RESET
-DTRB
-DTRA
-RTSA
-OPA
-RXRDYA
INTA
INTB
A0
A1
A2
XT
A
L
1
XT
A
L
2
-I
OW
-C
D
B
GN
D
-
R
X
RDY
B
-I
OR
-D
S
R
B
-R
I
B
-R
T
S
B
-C
T
S
B
D4
D3
D2
D1
D0
-T
X
R
D
Y
A
VC
C
-R
I
A
-C
D
A
-D
S
R
A
-C
T
S
A
XR16C2850CJ
Preliminary
Information
XR16C2850
2
Rev. 1.00P
48 Pin TQFP Package
40 Pin DIP Package
Figure 1, Package Descriptions, 40 pin, 48 pin XR16C2850
48
47
46
45
44
43
42
41
40
39
38
37
1
2
3
4
5
6
7
8
9
10
11
12
36
35
34
33
32
31
30
29
28
27
26
25
13
14
15
16
17
18
19
20
21
22
23
24
D5
D6
D7
RXB
RXA
N.C.
TXA
TXB
-OPB
-CSA
-CSB
N.C.
XT
AL1
XT
AL2
-I
O
W
-C
D
B
GN
D
N.
C.
-I
O
R
-D
SR
B
-R
I
B
-R
T
S
B
-C
T
S
B
N.
C.
RESET
-DTRB
-DTRA
-RTSA
-OPA
N.C.
INTA
INTB
A0
A1
A2
N.C.
D4
D3
D2
D1
D0
N.
C.
VC
C
-R
I
A
-C
D
A
-D
SR
A
-C
T
S
A
-R
SC
T
L
XR16C2850CM
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
40
39
38
37
36
35
34
33
32
31
30
29
28
27
26
25
24
23
22
21
D0
D1
D2
D3
D4
D5
D6
D7
RXB
RXA
TXA
TXB
-OPB
-CSA
-CSB
XTAL1
XTAL2
-IOW
-CDB
GND
VCC
-RIA
-CDA
-DSRA
-CTSA
RESET
-DTRB
-DTRA
-RTSA
-OPA
INTA
INTB
A0
A1
A2
-CTSB
-RTSB
-RIB
-DSRB
-IOR
X
R
16C
2
8
5
0
C
P
XR16C2850
3
Rev. 1.00P
Figure 2, Block Diagram
D0-D7
-IOR
-IOW
RESET
A0-A2
-CS A/B
-RSCTL
INT A/B
-RXRDY A/B
-TXRDY A/B
-DTR A/B
-RTS A/B
-CTS A/B
-RI A/B
-CD A/B
-DSR A/B
TX A/B
TXIR A/B
RX A/B
RXIR A/B
XTAL1
XTAL2
Da
t
a
b
u
s
&
Con
t
r
o
l L
o
g
i
c
Re
gi
st
e
r
Se
l
e
c
t
Logi
c
Modem
Control
Logic
In
t
e
rru
p
t
Con
t
r
o
l
Logi
c
Transmit
FIFO
Registers
Flow
Control
Logic
Transmit
Shift
Register
Receive
FIFO
Registers
Flow
Control
Logic
Receive
Shift
Register
In
t
e
r Co
n
n
e
c
t

Bus

L
i
n
e
s
&
Con
t
r
o
l si
g
n
al
s
Cl
oc
k
&
Bau
d
Rat
e
Ge
n
e
r
a
to
r
Ir
Encoder
Ir
Decoder
XR16C2850
4
Rev. 1.00P
SYMBOL DESCRIPTION
Symbol
Pin
Signal
Pin Description
40
44
48
type
A0
28
31
28
I
Address-0 Select Bit. - Internal register address selection.
A1
27
30
27
I
Address-1 Select Bit. - Internal register address selection.
A2
26
29
26
I
Address-2 Select Bit. - Internal register address selection.
-CS A-B
14,15 16,17 10,11
I
Chip Select A, B (active low) - This function is associated
with individual channels, A through B. These pins enable
data transfers between the user CPU and the 2850 for the
channel(s) addressed. Individual UART sections (A, B) are
addressed by providing a logic 0 on the respective -CS A-
B pin.
D0-D7
1-8
2-9
44-48
I/O
1-3
Data Bus (Bi-directional) - These pins are the eight bit, three
state data bus for transferring information to or from the
controlling CPU. D0 is the least significant bit and the first
data bit in a transmit or receive serial data stream.
GND
20
22
17
Pwr
Signal and power ground.
INT A-B
30,29 33,32 30,29
O
Interrupt A, B (three state) - This function is associated with
individual channel interrupts, INT A-B. INT A-B are enabled
when MCR bit-3 is set to a logic 1, interrupts are enabled in
the interrupt enable register (IER), and when an interrupt
condition exists. Interrupt conditions include: receiver er-
rors, available receiver buffer data, transmit buffer empty,
or when a modem status flag is detected.
-IOR
21
24
19
I
Read strobe (active low strobe) - A logic 0 transition on this
pin will load the contents of an Internal register defined by
address bits A0-A2 onto the 2850 data bus (D0-D7) for
access by an external CPU.
-IOW
18
20
15
I
Write strobe (active low strobe) - A logic 0 transition on this
pin will transfer the contents of the data bus (D0-D7) from
the external CPU to an internal register that is defined by
address bits A0-A2.
XR16C2850
5
Rev. 1.00P
SYMBOL DESCRIPTION
Symbol
Pin
Signal
Pin Description
40
44
48
type
-OP2 A-B
31,13 35,15
32,9
O
Output -2 (User Defined) - This function is associated with
individual channels, A through B. The state at these pin(s)
are defined by the user and through the software setting of
MCR register bit-3. INT A-B are set to the active mode and
OP2 to a logic 0 when MCR-3 is set to a logic 1. INT A-B are
set to the three state mode and OP2 to a logic 1 when MCR-
3 is set to a logic 0. See bit-3, Modem Control Register
(MCR bit-3).
RESET
35
39
36
I
Reset (active high) - A logic 1 on this pin will reset the
internal registers and all the outputs. The UART transmitter
output and the receiver input will be disabled during reset
time (see XR16C2850 External Reset Conditions for initial-
ization details).
-RXRDY A-B
-
34,23 31,18
O
Receive Ready A-B (active low) - This function is associ-
ated with 44 pin PLCC and 48 pin TQFP packages only. This
function provides the RX FIFO/RHR status for individual
receive channels (A-B). RXRDY is primarily intended for
monitoring DMA mode 1 transfers for the receive data
FIFOs. A logic 0 indicates there is receive data to read/
unload, i.e., receive ready status with one or more RX
characters available in the FIFO/RHR. This pin is a logic 1
when the FIFO/RHR is empty or when the programmed
trigger level has not been reached. This signal can also be
used for single mode transfers (DMA mode 0).
-TXRDY A-B
-
1,12
43,6
O
Transmit Ready A-B (active low) - This function is associ-
ated with 44 pin PLCC and 48 pin TQFP packages only.
These outputs provide the TX FIFO/THR status for indi-
vidual transmit channels (A-B). TXRDY is primarily in-
tended for monitoring DMA mode 1 transfers for the trans-
mit data FIFOs. An individual channels -TXRDY A-B buffer
ready status is indicated by logic 0, i.e., at least one location
is empty and available in the FIFO or THR. This pin goes to
a logic 1 when there are no more empty locations in the
FIFO or THR. This signal can also be used for single mode
transfers (DMA mode 0).
VCC
40
44
42
Pwr
Power supply input.
XR16C2850
6
Rev. 1.00P
SYMBOL DESCRIPTION
Symbol
Pin
Signal
Pin Description
40
44
48
type
XTAL1
16
18
13
I
Crystal or External Clock Input - Functions as a crystal input
or as an external clock input. A crystal can be connected
between this pin and XTAL2 to form an internal oscillator
circuit. This configuration requires an external 1 MW resis-
tor between the XTAL1 and XTAL2 pins. Alternatively, an
external clock can be connected to this pin to provide
custom data rates (see Baud Rate Generator Program-
ming).
XTAL2
17
19
14
O
Output of the Crystal Oscillator or Buffered Clock - (see also
XTAL1). Crystal oscillator output or buffered clock output.
Should be left open if an external clock is connected to
XTAL1.
-CD A-B
38,19 42,21 40,16
I
Carrier Detect (active low) - These inputs are associated
with individual UART channels A through B. A logic 0 on this
pin indicates that a carrier has been detected by the modem
for that channel.
-CTS A-B
36,25 40,28 38,23
I
Clear to Send (active low) - These inputs are associated with
individual UART channels, A through B. A logic 0 on the -
CTS pin indicates the modem or data set is ready to accept
transmit data from the 2850. Status can be tested by reading
MSR bit-4. This pin has no effect on the UARTs transmit or
receive operation.
-DSR A-B
37,22 41,25 39,20
I
Data Set Ready (active low) - These inputs are associated
with individual UART channels, A through B. A logic 0 on
this pin indicates the modem or data set is powered-on and
is ready for data exchange with the UART. This pin has no
effect on the UARTs transmit or receive operation.
-DTR A-B
33,34 37,38 34,35
O
Data Terminal Ready (active low) - These outputs are
associated with individual UART channels, A through B. A
logic 0 on this pin indicates that the 2850 is powered-on and
ready. This pin can be controlled via the modem control
register. Writing a logic 1 to MCR bit-0 will set the -DTR
output to logic 0, enabling the modem. This pin will be a logic
1 after writing a logic 0 to MCR bit-0, or after a reset. This
XR16C2850
7
Rev. 1.00P
SYMBOL DESCRIPTION
Symbol
Pin
Signal
Pin Description
40
44
48
type
pin has no effect on the UARTs transmit or receive opera-
tion.
-RI A-B
39,23 43,26 41,21
I
Ring Indicator (active low) - These inputs are associated
with individual UART channels, A through B. A logic 0 on
this pin indicates the modem has received a ringing signal
from the telephone line. A logic 1 transition on this input pin
will generate an interrupt.
-RTS A-B
32,24 36,27 33,22
O
Request to Send (active low) - These outputs are associated
with individual UART channels, A through B. A logic 0 on the
-RTS pin indicates the transmitter has data ready and
waiting to send. Writing a logic 1 in the modem control
register (MCR bit-1) will set this pin to a logic 0 indicating
data is available. After a reset this pin will be set to a logic
1. This pin has no effect on the UARTs transmit or receive
operation.
RX A-B
10,9
11,10
5,4
I
Receive Data (A-B) - These inputs are associated with
individual serial channel data to the 2850 receive input
circuits, A-B. The RX signal will be a logic 1 during reset, idle
(no data), or when the transmitter is disabled. During the
local loopback mode, the RX input pin is disabled and TX
data is connected to the UART RX Input, internally.
TX A-B
11,12 13,14
7,8
O
Transmit Data (A-B) - These outputs are associated with
individual serial transmit channel data from the 2850. The
TX signal will be a logic 1 during reset, idle (no data), or when
the transmitter is disabled. During the local loopback mode,
the TX output pin is disabled and TX data is internally
connected to the UART RX Input.
-RSCTL
-
-
37
I
RS-485 function select. When this pin is pulled high, normal
-RTS function is selected. RS-485 direction control can be
activated by connecting this pin to GND. This pin is wired
Or-ed with FCTR Bit-3.
XR16C2850
8
Rev. 1.00P
GENERAL DESCRIPTION
The XR16C2850 provides serial asynchronous re-
ceive data synchronization, parallel-to-serial and se-
rial-to-parallel data conversions for both the transmit-
ter and receiver sections. These functions are neces-
sary for converting the serial data stream into parallel
data that is required with digital data systems. Syn-
chronization for the serial data stream is accom-
plished by adding start and stops bits to the transmit
data to form a data character (character orientated
protocol). Data integrity is insured by attaching a parity
bit to the data character. The parity bit is checked by
the receiver for any transmission bit errors. The elec-
tronic circuitry to provide all these functions is fairly
complex especially when manufactured on a single
integrated silicon chip. The XR16C2850 represents
such an integration with greatly enhanced features.
The 2850 is fabricated with an advanced CMOS
process.
The 2850 is an upward solution that provides 128
bytes of transmit and receive FIFO memory, instead
of 16 bytes provided in the 16C2550. The 2850 is
designed to work with high speed modems and shared
network environments, that require fast data process-
ing time. Increased performance is realized in the
2850 by the larger transmit and receive FIFO. This
allows the external processor to handle more network-
ing tasks within a given time. For example, the
ST16C2550 with a 16 byte FIFO, unloads 16 bytes of
receive data in 1.53 ms (this example uses a character
length of 11 bits, including start/stop bits at
115.2Kbps). This means the external CPU will have to
service the receive FIFO at 1.53 ms intervals. How-
ever with the 128 byte FIFO in the 2850, the data
buffer will not require unloading/loading for 12.2 ms.
This increases the service interval giving the external
CPU additional time for other applications and reduc-
ing the overall UART interrupt servicing time. In
addition, the programmable levels of FIFO trigger
interrupt and automatic hardware/software flow con-
trol is uniquely provided for maximum data throughput
performance especially when operating in a multi-
channel environment. The combination of the above
greatly reduces the bandwidth requirement of the
external controlling CPU, increases performance, and
reduces power consumption.
The 2850 provides RS-485 half dulpex control signal
to select the external transceiver direction. Auto RS-
485 control pin (-RTS) is not activated after reset. To
activate the direction control function, user has to set
EFR Bit-4, and FCTR Bit-3 to 1. The -RTS pin is
normally high for receive mode and it will go low when
transmitter starts transmitting data.
FUNCTIONAL DESCRIPTIONS
UART A-B Functions
The UART provides the user with the capability to Bi-
directionally transfer information between an external
CPU and an external serial communication device. A
logic 0 on chip select pins -CSA and/or -CSB allows
the user to configure, send data, and/or receive data
via UART channels A-B. Individual channel select
functions are shown in Table 2 below.
Table 2, SERIAL PORT SELECTION GUIDE
CHIP SELECT
Function
-CS A-B = 1s
None
-CS A = 0
UART CHANNEL A
-CS B = 0
UART CHANNEL B
Internal Registers
The 2850 provides 15 internal registers for monitoring
and control. These resisters are shown in Table 3.
Twelve registers are similar to those already available
in the standard 16C2550. These registers function as
data holding registers (THR/RHR), interrupt status
and control registers (IER/ISR), a FIFO control regis-
ter (FCR), line status and control registers, (LCR/
LSR), modem status and control registers (MCR/
MSR), programmable data rate (clock) control regis-
ters (DLL/DLM), and a user accessible scratchpad
register (SPR). Beyond the general 16C2550 features
and capabilities, the 2850 offers an enhanced feature
register set (EFR, Xon/Xoff 1-2) that provides on
board hardware/software flow control. Register func-
tions are more fully described in the following para-
graphs.
XR16C2850
9
Rev. 1.00P
Table 3, INTERNAL REGISTER DECODE
A2
A1
A0
READ MODE
WRITE MODE
General Register Set (THR/RHR, IER/ISR, MCR/MSR, LCR/LSR, SPR):
0
0
0
Receive Holding Register
Transmit Holding Register
0
0
1
Interrupt Enable Register
0
1
0
Interrupt Status Register
FIFO Control Register
0
1
1
Line Control Register
1
0
0
Modem Control Register
1
0
1
Line Status Register
1
1
0
Modem Status Register
1
1
1
Scratchpad Register
Scratchpad Register
Baud Rate Register Set (DLL/DLM): Note *3
0
0
0
LSB of Divisor Latch
LSB of Divisor Latch
0
0
1
MSB of Divisor Latch
MSB of Divisor Latch
Enhanced Register Set (EFR, Xon/off 1-2): Note *4
0
0
0
FIFO Trigger Register
FIFO trigger counter
0
0
1
Feature Control Register
0
1
0
Enhanced Feature Register
Enhanced Feature Register
1
0
0
Xon-1 Word
Xon-1 Word
1
0
1
Xon-2 Word
Xon-2 Word
1
1
0
Xoff-1 Word
Xoff-1 Word
1
1
1
Xoff-2 Word
Xoff-2 Word
1
1
1
Enhanced Mode Select Register
Note *3: These registers are accessible only when LCR bit-7 is set to a logic 1.
Note *4: Enhanced Feature Register, Xon 1,2 and Xoff 1,2 are accessible only when the LCR is set to BF (HEX).
XR16C2850
10
Rev. 1.00P
FIFO Operation
The 128 byte transmit and receive data FIFO are
enabled by the FIFO Control Register (FCR) bit-0.
With 16C2550 devices, the user can set the receive
trigger level but not the transmit trigger level. The
2850 provides independent trigger levels for both
receiver and transmitter. To remain compatible with
ST16C2550, the transmit interrupt trigger level is set
to 16 following a reset. It should be noted that the user
can set the transmit trigger levels by writing to the FCR
register, but activation will not take place until EFR bit-
4 is set to a logic 1. The receiver FIFO section includes
a time-out function to ensure data is delivered to the
external CPU. An interrupt is generated whenever the
Receive Holding Register (RHR) has not been read
following the loading of a character or the receive
trigger level has not been reached. (see hardware flow
control for a description of this timing).
Hardware Flow Control
When automatic hardware flow control is enabled, the
2850 monitors the -CTS pin for a remote buffer
overflow indication and controls the -RTS pin for local
buffer overflows. Automatic hardware flow control is
selected by setting bits 6 (RTS) and 7 (CTS) of the
EFR register to a logic 1. If -CTS transitions from a
logic 0 to a logic 1 indicating a flow control request, ISR
bit-5 will be set to a logic 1 (if enabled via IER bit 6-7),
and the 2850 will suspend TX transmissions as soon
as the stop bit of the character in process is shifted out.
Transmission is resumed after the -CTS input returns
to a logic 0, indicating more data may be sent.
With the Auto RTS function enabled, an interrupt is
generated when the receive FIFO reaches the pro-
grammed trigger level. The -RTS pin will not be forced
to a logic 1 (RTS Off), until the receive FIFO reaches
the next trigger level. The -RTS pin will return to a logic
0 after the data buffer (FIFO) is unloaded to the next
trigger level below the programmed trigger level.
Under the above described conditions the 2850 will
continue to accept data until the receive FIFO is full.
Example of 650 trigger level selection
Selected
INT
-RTS
-RTS
Trigger
Pin
Logic 1
Logic 0
Level
Activation
(characters)
(characters)
(characters)
8
8
16
0
16
16
24
8
24
24
28
16
28
28
28
24
XR16C2850
11
Rev. 1.00P
Software Flow Control
When software flow control is enabled, the 2850
compares one or two sequential receive data charac-
ters with the programmed Xon or Xoff-1,2 character
value(s). If receive character(s) (RX) match the pro-
grammed values, the 2850 will halt transmission (TX)
as soon as the current character(s) has completed
transmission. When a match occurs, the receive
ready (if enabled via Xoff IER bit-5) flags will be set
and the interrupt output pin (if receive interrupt is
enabled) will be activated. Following a suspension
due to a match of the Xoff characters values, the 2850
will monitor the receive data stream for a match to the
Xon-1,2 character value(s). If a match is found, the
2850 will resume operation and clear the flags (ISR
bit-4).
Reset initially sets the contents of the Xon/Xoff 8-bit
flow control registers to a logic 0. Following reset the
user can write any Xon/Xoff value desired for software
flow control. Different conditions can be set to detect
Xon/Xoff characters and suspend/resume transmis-
sions. When double 8-bit Xon/Xoff characters are
selected, the 2850 compares two consecutive receive
characters with two software flow control 8-bit values
(Xon1, Xon2, Xoff1, Xoff2) and controls TX transmis-
sions accordingly. Under the above described flow
control mechanisms, flow control characters are not
placed (stacked) in the user accessible RX data buffer
or FIFO.
In the event that the receive buffer is overfilling and
flow control needs to be executed, the 2850 automati-
cally sends an Xoff message (when enabled) via the
serial TX output to the remote modem. The 2850
sends the Xoff-1,2 characters as soon as received
data passes the programmed trigger level. To clear
this condition, the 2850 will transmit the programmed
Xon-1,2 characters as soon as receive data drops
below the programmed trigger level.
Special Feature Software Flow Control
A special feature is provided to detect an 8-bit charac-
ter when bit-5 is set in the Enhanced Feature Register
(EFR). When this character is detected, it will be
placed on the user accessible data stack along with
normal incoming RX data. This condition is selected in
conjunction with EFR bits 0-3. Note that software flow
control should be turned off when using this special
mode by setting EFR bit 0-3 to a logic 0.
The 2850 compares each incoming receive character
with Xoff-2 data. If a match exists, the received data
will be transferred to FIFO and ISR bit-4 will be set to
indicate detection of special character (see Figure 9).
Although the Internal Register Table shows each X-
Register with eight bits of character information, the
actual number of bits is dependent on the pro-
grammed word length. Line Control Register (LCR)
bits 0-1 defines the number of character bits, i.e.,
either 5 bits, 6 bits, 7 bits, or 8 bits. The word length
selected by LCR bits 0-1 also determines the number
of bits that will be used for the special character
comparison. Bit-0 in the X-registers corresponds with
the LSB bit for the receive character.
Time-out Interrupts
Three special interrupts have been added to monitor
the hardware and software flow control. The interrupts
are enabled by IER bits 5-7. Care must be taken when
handling these interrupts. Following a reset the trans-
mitter interrupt is enabled, the 2850 will issue an
interrupt to indicate that transmit holding register is
empty. This interrupt must be serviced prior to con-
tinuing operations. The LSR register provides the
current singular highest priority interrupt only. It could
be noted that CTS and RTS interrupts have lowest
interrupt priority. A condition can exist where a higher
priority interrupt may mask the lower priority CTS/
RTS interrupt(s). Only after servicing the higher pend-
ing interrupt will the lower priority CTS/ RTS
interrupt(s) be reflected in the status register. Servic-
ing the interrupt without investigating further interrupt
conditions can result in data errors.
When two interrupt conditions have the same priority,
it is important to service these interrupts correctly.
Receive Data Ready and Receive Time Out have the
same interrupt priority (when enabled by IER bit-0).
The receiver issues an interrupt after the number of
characters have reached the programmed trigger
level. In this case the 2850 FIFO may hold more
characters than the programmed trigger level. Follow-
XR16C2850
12
Rev. 1.00P
ing the removal of a data byte, the user should recheck
LSR bit-0 for additional characters. A Receive Time
Out will not occur if the receive FIFO is empty. The
time out counter is reset at the center of each stop bit
received or each time the receive holding register
(RHR) is read. The actual time out value is T (Time out
length in bits) = 4 X P (Programmed word length) + 12.
To convert the time out value to a character value, the
user has to consider the complete word length, includ-
ing data information length, start bit, parity bit, and the
size of stop bit, i.e., 1X, 1.5X, or 2X bit times.
Example -A: If the user programs a word length of 7,
with no parity and one stop bit, the time out will be:
T = 4 X 7( programmed word length) +12 = 40 bit times.
The character time will be equal to 40 / 9 = 4.4
characters, or as shown in the fully worked out ex-
ample: T = [(programmed word length = 7) + (stop bit
= 1) + (start bit = 1) = 9]. 40 (bit times divided by 9) =
4.4 characters.
Example -B: If the user programs the word length = 7,
with parity and one stop bit, the time out will be:
T = 4 X 7(programmed word length) + 12 = 40 bit times.
Character time = 40 / 10 [ (programmed word length
= 7) + (parity = 1) + (stop bit = 1) + (start bit = 1)] = 4
characters.
Programmable Baud Rate Generator
The 2850 supports high speed modem technologies
that have increased input data rates by employing
data compression schemes. For example a 33.6Kbps
modem that employs data compression may require a
115.2Kbps input data rate. A 128.0Kbps ISDN modem
that supports data compression may need an input
data rate of 460.8Kbps. The 2850 can support a
standard data rate of 921.6Kbps.
A single baud rate generator is provided for the
transmitter and receiver, allowing independent TX/RX
channel control. The programmable Baud Rate
Generator is capable of accepting an input clock up to
24 MHz, as required for supporting a 1.5Mbps data
rate. The 2850 can be configured for internal or
external clock operation. For internal clock oscillator
operation, an industry standard microprocessor crys-
tal (parallel resonant 22-33 pF load) is connected
externally between the XTAL1 and XTAL2 pins, with
an external 1 M
resistor across it. Alternatively, an
external clock can be connected to the XTAL1 pin to
clock the internal baud rate generator for standard or
custom rates.
The generator divides the input 16X clock by any
divisor from 1 to 2
16
-1. The 2850 divides the basic
crystal or external clock by 16. Further division of this
16X clock provides two table rates to support low and
high data rate applications using the same system
design. The two rate tables are selectable through the
internal register, MCR bit-7. Setting MCR bit-7 to a
logic 1 provides an additional divide by 4 whereas,
setting MCR bit-7 to a logic 0 only divides by 1 (see
Table 4 and Figure 11). The frequency of the -
BAUDOUT output pin is exactly 16X (16 times) of the
selected baud rate (-BAUDOUT =16 x Baud Rate).
Customized Baud Rates can be achieved by selecting
the proper divisor values for the MSB and LSB sec-
tions of baud rate generator.
C1
22pF
C2
33pF
X1
1.8432 MHz
R1
50-120
R2
1M
XTA
L
1
XTA
L
2
Crystal oscillator connection
XR16C2850
13
Rev. 1.00P
Programming the Baud Rate Generator Registers
DLM (MSB) and DLL (LSB) provides a user capability
for selecting the desired final baud rate. The example
in Table 4 below, shows the two selectable baud rate
tables available when using a 7.3728 MHz crystal.
Divide
by
1 logic
XTAL1
XTAL2
Divide
by
4 logic
Clock
Oscillator
Logic
Baudrate
Generator
Logic
-BAUDOUT
MCR
Bit-7=0
MCR
Bit-7=1
Table 4, BAUD RATE GENERATOR PROGRAMMING TABLE (7.3728 MHz CLOCK):
Output
Output
User
User
DLM
DLL
Baud Rate
Baud Rate
16 x Clock
16 x Clock
Program
Program
MCR
MCR
Divisor
Divisor
Value
Value
BIT-7=1
Bit-7=0
(Decimal)
(HEX)
(HEX)
(HEX)
50
200
2304
900
09
00
75
300
1536
600
06
00
150
600
768
300
03
00
300
1200
384
180
01
80
600
2400
192
C0
00
C0
1200
4800
96
60
00
60
2400
9600
48
30
00
30
4800
19.2K
24
18
00
18
7200
28.8K
16
10
00
10
9600
38.4k
12
0C
00
0C
19.2k
76.8k
6
06
00
06
38.4k
153.6k
3
03
00
03
57.6k
230.4k
2
02
00
02
115.2k
460.8k
1
01
00
01
Figure 11, Baud Rate Generator Circuitry
XR16C2850
14
Rev. 1.00P
DMA Operation
The 2850 FIFO trigger level provides additional flex-
ibility to the user for block mode operation. LSR bits 5-
6 provide an indication when the transmitter is empty
or has an empty location(s). The user can optionally
operate the transmit and receive FIFO in the DMA
mode (FCR bit-3). When the transmit and receive
FIFO are enabled and the DMA mode is deactivated
(DMA Mode 0), the 2850 activates the interrupt
output pin for each data transmit or receive operation.
When DMA mode is activated (DMA Mode 1), the
user takes the advantage of block mode operation by
loading or unloading the FIFO in a block sequence
determined by the preset trigger level. In this mode,
the 2850 sets the interrupt output pin when characters
in the transmit FIFO are below the transmit trigger
level, or the characters in the receive FIFO are above
the receive trigger level.
Sleep Mode
The 2850 is designed to operate with low power
consumption. A special sleep mode is included to
further reduce power consumption when the chip is
not being used. With EFR bit-4 and IER bit-4 enabled
(set to a logic 1), the 2850 enters the sleep mode but
resumes normal operation when a start bit is detected,
a change of state on any of the modem input pins RX,
-RI, -CTS, -DSR, -CD, or transmit data is provided by
the user. If the sleep mode is enabled and the 2850 is
awakened by one of the conditions described above,
it will return to the sleep mode automatically after the
last character is transmitted or read by the user. In any
case, the sleep mode will not be entered while an
interrupt(s) is pending. The 2850 will stay in the sleep
mode of operation until it is disabled by setting IER bit-
4 to a logic 0.
Loopback Mode
The internal loopback capability allows onboard diag-
nostics. In the loopback mode the normal modem
interface pins are disconnected and reconfigured for
loopback internally. In this mode MSR bits 4-7 are also
disconnected. However, MCR register bits 0-3 can be
used for controlling loopback diagnostic testing. In the
loopback mode, OP1 and OP2 in the MCR register
(bits 0-1) control the modem -RI and -CD inputs
respectively. MCR signals -DTR and -RTS (bits 0-1)
are used to control the modem -CTS and -DSR inputs
respectively. The transmitter output (TX) and the
receiver input (RX) are disconnected from their asso-
ciated interface pins, and instead are connected to-
gether internally (see Figure 12). The -CTS, -DSR, -
CD, and -RI are disconnected from their normal
modem control inputs pins, and instead are connected
internally to -DTR, -RTS, -OP1 and -OP2. Loopback
test data is entered into the transmit holding register
via the user data bus interface, D0-D7. The transmit
UART serializes the data and passes the serial data to
the receive UART via the internal loopback connec-
tion. The receive UART converts the serial data back
into parallel data that is then made available at the
user data interface, D0-D7. The user optionally com-
pares the received data to the initial transmitted data
for verifying error free operation of the UART TX/RX
circuits.
In this mode , the receiver and transmitter interrupts
are fully operational. The Modem Control Interrupts
are also operational. However, the interrupts can only
be read using the lower four bits of the Modem Control
Register (MCR bits 0-3) instead of the four Modem
Status Register bits 4-7. The interrupts are still con-
trolled by the IER.
XR16C2850
15
Rev. 1.00P
Figure 12, Internal Loopback Mode Diagram
D0-D7
-IOR,-IOW
RESET
A0-A2
-CS A/B
INT A/B
-RXRDY
-TXRDY
TX A/B
RX A/B
Dat
a
b
u
s
&
Con
t
r
o
l
Log
i
c
Regi
s
t
e
r
Sel
ect
Lo
g
i
c
M
odem
Con
t
r
o
l
L
ogic
I
n
ter
r
upt
Con
t
r
o
l
L
ogic
Transmit
FIFO
Registers
Flow
Control
Logic
Transmit
Shift
Register
Receive
FIFO
Registers
Flow
Control
Logic
Receive
Shift
Register
In
t
e
r C
o
n
n
ec
t
B
u
s L
i
n
e
s
&
C
o
n
t
ro
l
si
g
n
a
l
s
Cl
ock &
Bau
d
R
a
te
Gen
e
r
a
tor
XTAL1
XTAL2
Ir
Encoder
Ir
Decoder
-CTS A/B
-RTS A/B
-DTR A-D
-DSR A/B
-RI A/B
-CD A/B
-OP2 A/B
MC
R Bi
t
-
4
=
1
(-OP1 A/B)
XR16C2850
16
Rev. 1.00P
REGISTER FUNCTIONAL DESCRIPTIONS
The following table delineates the assigned bit functions for the fifteen 2850 internal registers. The assigned
bit functions are more fully defined in the following paragraphs.
XR16C2850 ACCESSIBLE REGISTERS
A2 A1 A0
Register
BIT-7
BIT-6
BIT-5
BIT-4
BIT-3
BIT-2
BIT-1
BIT-0
[Default]
Note *5
General Register Set
0 0 0
RHR [XX]
bit-7
bit-6
bit-5
bit-4
bit-3
bit-2
bit-1
bit-0
0 0 0
THR [XX]
bit-7
bit-6
bit-5
bit-4
bit-3
bit-2
bit-1
bit-0
0 0 1
IER [00]
0/
0/
0/
0/
modem
receive
transmit
receive
-CTS
-RTS
Xoff
Sleep
status
line
holding
holding
interrupt
interrupt
interrupt
mode
interrupt
status
register
register
interrupt
0 1 0
FCR [00]
RCVR
RCVR
0/TX
0/TX
DMA
XMIT
RCVR
FIFO
trigger
trigger
trigger
trigger
mode
FIFO
FIFO
enable
(MSB)
(LSB)
(MSB)
(LSB)
select
reset
reset
0 1 0
ISR [01]
0/
0/
0/
0/
int
int
int
int
FIFOs
FIFOs
-RTS,
Xoff
priority
priority
priority
status
enabled
enabled
-CTS
bit-2
bit-1
bit-0
0 1 1
LCR [00]
divisor
set
set
even
parity
stop
word
word
latch
break
parity
parity
enable
bits
length
length
enable
bit-1
bit-0
1 0 0
MCR [00]
Clock
0/
0/
loop
INT
-OP1
-RTS
-DTR
select
IRRT
Xon
back
Enable
enable
Any
1 0 1
LSR [60]
0/
THR &
THR
break
framing
parity
overrun
receive
FIFO
TSR
empty
interrupt
error
error
error
data
error
empty
ready
1 1 0
MSR [00]
-CD
-RI
-DSR
-CTS
delta
delta
delta
delta
-CD
-RI
-DSR
-CTS
1 1 1
SCPAD [FF]
bit-7
bit-6
bit-5
bit-4
bit-3
bit-2
bit-1
bit-0
Special Register Set: Note *3
0 0 0
DLL [00]
bit-7
bit-6
bit-5
bit-4
bit-3
bit-2
bit-1
bit-0
0 0 1
DLM [00]
bit-15
bit-14
bit-13
bit-12
bit-11
bit-10
bit-9
bit-8
XR16C2850
17
Rev. 1.00P
A2 A1 A0
Register
BIT-7
BIT-6
BIT-5
BIT-4
BIT-3
BIT-2
BIT-1
BIT-0
[Default]
Note *5
Enhanced Register Set: Note *4
1 0 0
Xon-1[00]
bit-7
bit-6
bit-5
bit-4
bit-3
bit-2
bit-1
bit-0
1 0 1
Xon-2[00]
bit-15
bit-14
bit-13
bit-12
bit-11
bit-10
bit-9
bit-8
1 1 0
Xoff-1[00]
bit-7
bit-6
bit-5
bit-4
bit-3
bit-2
bit-1
bit-0
1 1 1
Xoff-2[00]
bit-15
bit-14
bit-13
bit-12
bit-11
bit-10
bit-9
bit-8
0 0 0
TRG [00]
Trig/
Trig/
Trig/
Trig/
Trig
Trig/
Trig/
Trig/
FC
FC
FC
FC
FC
FC
FC
FC
0 0 1
FCTR [00]
Rx/Tx
SCPAD
Trig
Trig
RS485
IrRx
-RTS
-RTS
Mode
Swap
Bit-1
Bit-0
Auto
Inv.
Delay
Delay
control
Bit-1
Bit-0
0 1 0
EFR [00]
Auto
Auto
Special
Enable
Cont-3
Cont-2
Cont-1
Cont-0
-CTS
-RTS
Char.
IER
Tx,Rx
Tx,Rx
Tx,Rx
Tx,Rx
select
Bits 4-7,
Control
Control
Control
Control
ISR, FCR
Bits 4-5,
MCR
Bits 5-7
1 1 1
EMSR [00]
Not
Not
Not
Not
Not
Not
ALT.
Rx/-Tx
Used
Used
Used
Used
Used
Used
Rx/Tx
FIFO
FIFO
Count
Count
Note *3: The Special Register Set is accessible only when LCR bit-7 is set to a logic 1.
Note *4: Enhanced Feature Register, Xon 1,2 and Xoff 1,2 are accessible only when LCR is set to BF
Hex.
Note *5: The value represents the registers initialized HEX value. An X signifies a 4-bit un-initialized nibble.
XR16C2850
18
Rev. 1.00P
Transmit and Receive Holding Register
The serial transmitter section consists of an 8-bit
Transmit Hold Register (THR) and Transmit Shift
Register (TSR). The status of the THR is provided in
the Line Status Register (LSR). Writing to the THR
transfers the contents of the data bus (D7-D0) to the
THR, providing that the THR or TSR is empty. The
THR empty flag in the LSR register will be set to a logic
1 when the transmitter is empty or when data is
transferred to the TSR. Note that a write operation can
be performed when the transmit holding register
empty flag is set (logic 0 = FIFO full, logic 1= at least
one FIFO location available).
The serial receive section also contains an 8-bit
Receive Holding Register, RHR. Receive data is
removed from the 2850 and receive FIFO by reading
the RHR register. The receive section provides a
mechanism to prevent false starts. On the falling edge
of a start or false start bit, an internal receiver counter
starts counting clocks at 16x clock rate. After 7 1/2
clocks the start bit time should be shifted to the center
of the start bit. At this time, the start bit is sampled, and
if it is still a logic 0, it is validated. Evaluating the start
bit in this manner prevents the receiver from assem-
bling a false character. Receiver status codes will be
posted in the LSR.
DEVICE IDENTIFICATION
The XR16C2850 provides a Device Identification and
Device Revision code to distinguish the part from
others.
To read the identification number from the part, its is
required to set the baud rate generator divisor latch to
1 and then set the content of the baud rate generator
DLL and DLM registers to 0. Reading the content of
the DLM will provide 12 hex for XR16C2850 part and
reading the content of the DLL will provide the revision
of the part.
Interrupt Enable Register (IER)
The Interrupt Enable Register (IER) masks the inter-
rupts from receiver ready, transmitter empty, line
status and modem status registers. These interrupts
would normally be seen on the 2850 INT output pin.
IER Vs Receive FIFO Interrupt Mode Operation
When the receive FIFO (FCR BIT-0 = a logic 1) and
receive interrupts (IER BIT-0 = logic 1) are enabled,
the receive interrupts and register status will reflect
the following:
A) The receive data available interrupts are issued to
the external CPU when the FIFO has reached the
programmed trigger level. It will be cleared when the
FIFO drops below the programmed trigger level.
B) FIFO status will also be reflected in the user
accessible ISR register when the FIFO trigger level is
reached. Both the ISR register status bit and the
interrupt will be cleared when the FIFO drops below
the trigger level.
C) The data ready bit (LSR BIT-0) is set as soon as a
character is transferred from the shift register to the
receive FIFO. It is reset when the FIFO is empty.
IER Vs Receive/Transmit FIFO Polled Mode Op-
eration
When FCR BIT-0 equals a logic 1, resetting IER bits
0-3 enables the 2850 in the FIFO polled mode of
operation. Since the receiver and transmitter have
separate bits in the LSR, either or both can be used in
the polled mode by selecting respective transmit or
receive control bit(s).
A) LSR BIT-0 will be a logic 1 as long as there is one
byte in the receive FIFO.
B) LSR BIT 1-4 will indicate if an overrun error
occurred.
C) LSR BIT-5 will indicate when the transmit FIFO is
empty.
D) LSR BIT-6 will indicate when both the transmit
FIFO and transmit shift register are empty.
E) LSR BIT-7 will indicate any FIFO data errors.
XR16C2850
19
Rev. 1.00P
IER BIT-0:
Logic 0 = Disable the receiver ready interrupt (normal
default condition).
Logic 1 = Enable the receiver ready interrupt.
IER BIT-1:
Logic 0 = Disable the transmitter empty interrupt
(normal default condition).
Logic 1 = Enable the transmitter empty interrupt.
IER BIT-2:
Logic 0 = Disable the receiver line status interrupt
(normal default condition).
Logic 1 = Enable the receiver line status interrupt.
IER BIT-3:
Logic 0 = Disable the modem status register interrupt
(normal default condition).
Logic 1 = Enable the modem status register interrupt.
IER BIT -4:
Logic 0 = Disable sleep mode (normal default condi-
tion).
Logic 1 = Enable sleep mode. See Sleep Mode section
for details.
IER BIT-5:
Logic 0 = Disable the software flow control, receive
Xoff interrupt (normal default condition).
Logic 1 = Enable the software flow control, receive
Xoff interrupt. See Software Flow Control section for
details.
IER BIT-6:
Logic 0 = Disable the RTS interrupt (normal default
condition).
Logic 1 = Enable the RTS interrupt. The 2850 issues
an interrupt when the RTS pin transitions from a logic
0 to a logic 1.
IER BIT-7:
Logic 0 = Disable the CTS interrupt (normal default
condition).
Logic 1 = Enable the CTS interrupt. The 2850 issues
an interrupt when CTS pin transitions from a logic 0 to
a logic 1.
FIFO Control Register (FCR)
This register is used to enable the FIFOs, clear the
FIFOs, set the transmit/receive FIFO trigger levels,
and select the DMA mode. The DMA, and FIFO
modes are defined as follows:
DMA MODE
Mode 0
Set and enable the interrupt for each
single transmit or receive operation, and is similar to
the ST16C450 mode. Transmit Ready (-TXRDY) will
go to a logic 0 whenever an empty transmit space is
available in the Transmit Holding Register (THR).
Receive Ready (-RXRDY) will go to a logic 0 when-
ever the Receive Holding Register (RHR) is loaded
with a character.
Mode 1
Set and enable the interrupt in a block
mode operation. The transmit interrupt is set when the
transmit FIFO is below the programmed trigger level.
-TXRDY remains a logic 0 as long as one empty FIFO
location is available. The receive interrupt is set when
the receive FIFO fills to the programmed trigger level.
However the FIFO continues to fill regardless of the
programmed level until the FIFO is full. -RXRDY
remains a logic 0 as long as the FIFO fill level is above
the programmed trigger level.
FCR BIT-0:
Logic 0 = Disable the transmit and receive FIFO
(normal default condition).
Logic 1 = Enable the transmit and receive FIFO. This
bit must be a 1 when other FCR bits are written to or
they will not be programmed.
FCR BIT-1:
Logic 0 = No FIFO receive reset (normal default
condition).
Logic 1 = Clears the contents of the receive FIFO and
resets the FIFO counter logic (the receive shift regis-
ter is not cleared or altered). This bit will return to a
logic 0 after clearing the FIFO.
FCR BIT-2:
Logic 0 = No FIFO transmit reset (normal default
condition).
Logic 1 = Clears the contents of the transmit FIFO and
resets the FIFO counter logic (the transmit shift regis-
XR16C2850
20
Rev. 1.00P
ter is not cleared or altered). This bit will return to a
logic 0 after clearing the FIFO.
FCR BIT-3:
Logic 0 = Set DMA mode 0 (normal default condi-
tion).
Logic 1 = Set DMA mode 1.
Transmit operation in mode 0:
When the 2850 is in the ST16C450 mode (FIFOs
disabled, FCR bit-0 = logic 0) or in the FIFO mode
(FIFOs enabled, FCR bit-0 = logic 1, FCR bit-3 = logic
0) and when there are no characters in the transmit
FIFO or transmit holding register, the -TXRDY pin will
be a logic 0. Once active the -TXRDY pin will go to a
logic 1 after the first character is loaded into the
transmit holding register.
Receive operation in mode 0:
When the 2850 is in mode 0 (FCR bit-0 = logic 0) or
in the FIFO mode (FCR bit-0 = logic 1, FCR bit-3 =
logic 0) and there is at least one character in the
receive FIFO, the -RXRDY pin will be a logic 0. Once
active the -RXRDY pin will go to a logic 1 when there
are no more characters in the receiver.
Transmit operation in mode 1:
When the 2850 is in FIFO mode ( FCR bit-0 = logic 1,
FCR bit-3 = logic 1 ), the -TXRDY pin will be a logic 1
when the transmit FIFO is completely full. It will be a
logic 0 if one or more FIFO locations are empty.
Receive operation in mode 1:
When the 2850 is in FIFO mode (FCR bit-0 = logic 1,
FCR bit-3 = logic 1) and the trigger level has been
reached, or a Receive Time Out has occurred, the -
RXRDY pin will go to a logic 0. Once activated, it will
go to a logic 1 after there are no more characters in the
FIFO.
FCR BIT 4-5: (logic 0 or cleared is the default condi-
tion, TX trigger level = none)
The XR16C2850 provide 4 user selectable trigger
levels. The FCTR Bits 4-5 selects one of the following
tables. These bits are used to set the trigger level for
the transmit FIFO interrupt. The XR16C2850 will issue
a transmit empty interrupt when the number of char-
acters in FIFO drops below the selected trigger level.
TRIGGER TABLE-A (Transmit)
Default setting after reset ST16C550 mode
BIT-5
BIT-4
FIFO trigger level
X
X
None
TRIGGER TABLE-B (Transmit)
BIT-5
BIT-4
FIFO trigger level
0
0
16
0
1
8
1
0
24
1
1
30
TRIGGER TABLE-C (Transmit)
BIT-5
BIT-4
FIFO trigger level
0
0
8
0
1
16
1
0
32
1
1
56
TRIGGER TABLE-D (Transmit)
BIT-5
BIT-4
FIFO trigger level
X
X
User programmable
Trigger levels
FCR BIT 6-7: (logic 0 or cleared is the default condi-
tion, RX trigger level =8)
These bits are used to set the trigger level for the
receiver FIFO interrupt. The FCTR Bits 4-5 selects
one of the following table.
XR16C2850
21
Rev. 1.00P
TRIGGER TABLE-A (Receive)
Default setting after reset ST16C550 mode
BIT-7
BIT-6
FIFO trigger level
0
0
1
0
1
4
1
0
8
1
1
14
TRIGGER TABLE-B (Receive)
BIT-7
BIT-6
FIFO trigger level
0
0
8
0
1
16
1
0
24
1
1
28
TRIGGER TABLE-C (Receive)
BIT-7
BIT-6
FIFO trigger level
0
0
8
0
1
16
1
0
56
1
1
60
TRIGGER TABLE-D (Receive)
BIT-7
BIT-6
FIFO trigger level
X
X
User programmable
Trigger levels
Interrupt Status Register (ISR)
The 2850 provides six levels of prioritized interrupts to
minimize external software interaction. The Interrupt
Status Register (ISR) provides the user with six inter-
rupt status bits. Performing a read cycle on the ISR will
provide the user with the highest pending interrupt
level to be serviced. No other interrupts are acknowl-
edged until the pending interrupt is serviced. When-
ever the interrupt status register is read, the interrupt
status is cleared. However it should be noted that only
the current pending interrupt is cleared by the read. A
lower level interrupt may be seen after rereading the
interrupt status bits. The Interrupt Source Table. Table
6, shows the data values (bit 0-5) for the six prioritized
interrupt levels and the interrupt sources associated
with each of these interrupt levels:
XR16C2850
22
Rev. 1.00P
Table 6, INTERRUPT SOURCE TABLE
Priority
[ ISR BITS ]
Level
Bit-5 Bit-4 Bit-3 Bit-2 Bit-1 Bit-0
Source of the interrupt
1
0
0
0
1
1
0
LSR (Receiver Line Status Register)
2
0
0
0
1
0
0
RXRDY (Received Data Ready)
2
0
0
1
1
0
0
RXRDY (Receive Data time out)
3
0
0
0
0
1
0
TXRDY ( Transmitter Holding Register Empty)
4
0
0
0
0
0
0
MSR (Modem Status Register)
5
0
1
0
0
0
0
RXRDY (Received Xoff signal)/ Special character
6
1
0
0
0
0
0
CTS, RTS change of state
ISR BIT-0:
Logic 0 = An interrupt is pending and the ISR contents
may be used as a pointer to the appropriate interrupt
service routine.
Logic 1 = No interrupt pending (normal default condi-
tion).
ISR BIT 1-3: (logic 0 or cleared is the default condition)
These bits indicate the source for a pending interrupt
at interrupt priority levels 1, 2, and 3 (see Interrupt
Source Table).
ISR BIT 4-5: (logic 0 or cleared is the default condition)
These bits are enabled when EFR bit-4 is set to a logic
1. ISR bit-4 indicates that matching Xoff character(s)
have been detected. ISR bit-5 indicates that CTS,
RTS have been generated. Note that once set to a
logic 1, the ISR bit-4 will stay a logic 1 until Xon
character(s) are received.
ISR BIT 6-7: (logic 0 or cleared is the default condition)
These bits are set to a logic 0 when the FIFO is not
being used. They are set to a logic 1 when the FIFOs
are enabled
Line Control Register (LCR)
The Line Control Register is used to specify the
asynchronous data communication format. The word
length, the number of stop bits, and the parity are
selected by writing the appropriate bits in this register.
LCR BIT 0-1: (logic 0 or cleared is the default condi-
tion)
These two bits specify the word length to be transmit-
ted or received.
BIT-1
BIT-0
Word length
0
0
5
0
1
6
1
0
7
1
1
8
LCR BIT-2: (logic 0 or cleared is the default condition)
The length of stop bit is specified by this bit in
conjunction with the programmed word length.
BIT-2
Word length
Stop bit
length
(Bit time(s))
0
5,6,7,8
1
1
5
1-1/2
1
6,7,8
2
XR16C2850
23
Rev. 1.00P
LCR BIT-3:
Parity or no parity can be selected via this bit.
Logic 0 = No parity (normal default condition)
Logic 1 = A parity bit is generated during the transmis-
sion, receiver checks the data and parity for transmis-
sion errors.
LCR BIT-4:
If the parity bit is enabled with LCR bit-3 set to a logic
1, LCR BIT-4 selects the even or odd parity format.
Logic 0 = ODD Parity is generated by forcing an odd
number of logic 1s in the transmitted data. The
receiver must be programmed to check the same
format. (normal default condition)
Logic 1 = EVEN Parity is generated by forcing an even
the number of logic 1s in the transmitted. The receiver
must be programmed to check the same format.
LCR BIT-5:
If the parity bit is enabled, LCR BIT-5 selects the
forced parity format.
LCR BIT-5 = logic 0, parity is not forced (normal
default condition).
LCR BIT-5 = logic 1 and LCR BIT-4 = logic 0, parity bit
is forced to a logical 1 for the transmit and receive
data.
LCR BIT-5 = logic 1 and LCR BIT-4 = logic 1, parity bit
is forced to a logical 0 for the transmit and receive
data.
LCR
LCR
LCR
Parity selection
Bit-3
Bit-4
Bit-5
0
X
X
No parity
1
0
0
Odd parity
1
1
0
Even parity
1
0
1
Force parity 1
1
1
1
Forced parity 0
LCR BIT-6:
When enabled, the Break control bit causes a break
condition to be transmitted (the TX output is forced to
a logic 0 state). This condition exists until disabled by
setting LCR bit-6 to a logic 0.
Logic 0 = No TX break condition (normal default
condition).
Logic 1 = Forces the transmitter output (TX) to a logic
0 for alerting the remote receiver to a line break
condition.
LCR BIT-7:
The internal baud rate counter latch and Enhance
Feature mode enable.
Logic 0 = Divisor latch disabled (normal default con-
dition).
Logic 1 = Divisor latch and enhanced feature register
enabled.
Modem Control Register (MCR)
This register controls the interface with the modem or
a peripheral device.
MCR BIT-0:
Logic 0 = Force -DTR output to a logic 1 (normal
default condition).
Logic 1 = Force -DTR output to a logic 0.
MCR BIT-1:
Logic 0 = Force -RTS output to a logic 1 (normal
default condition).
Logic 1 = Force -RTS output to a logic 0.
Automatic RTS may be used for hardware flow control
by enabling EFR bit-6 (see EFR bit-6).
MCR BIT-2:
Internal loop back mode only.
Logic 0 = Set -OP1 output to a logic 1. (normal default
condition)
Logic 1 = Set -OP1 output to a logic 0.
MCR BIT-3:
Logic 0 = Forces INT outputs to three state mode
(normal default condition).
Logic 1 = Forces the INT outputs to the active mode.
MCR BIT-4:
Logic 0 = Disable loopback mode (normal default
condition).
Logic 1 = Enable local loopback mode (diagnostics).
MCR BIT-5:
Logic 0 = Disable Xon-Any function (for 16C550
compatibility, normal default condition).
XR16C2850
24
Rev. 1.00P
Logic 1 = Enable Xon-Any function. In this mode, any
RX character received will enable Xon.
MCR BIT-6:
Logic 0 = Enable Modem receive and transmit input/
output interface (normal default condition).
Logic 1 = Enable infrared IrDA receive and transmit
inputs/outputs. While in this mode, the TX/RX output/
Inputs are routed to the infrared encoder/decoder. The
data input and output levels will conform to the IrDA
infrared interface requirement. As such, while in this
mode the infrared TX output will be a logic 0 during idle
data conditions.
MCR BIT-7:
Logic 0 = Divide by one. The input clock (crystal or
external) is divided by sixteen and then presented to
the Programmable Baud Rate Generator (BGR) with-
out further modification, i.e., divide by one (normal,
default condition).
Logic 1 = Divide by four. The divide by one clock
described in MCR bit-7 equals a logic 0, is further
divided by four (also see Programmable Baud Rate
Generator section).
Line Status Register (LSR)
This register provides the status of data transfers
between. the 2850 and the CPU.
LSR BIT-0:
Logic 0 = No data in receive holding register or FIFO
(normal default condition).
Logic 1 = Data has been received and is saved in the
receive holding register or FIFO.
LSR BIT-1:
Logic 0 = No overrun error (normal default condition).
Logic 1 = Overrun error. A data overrun error occurred
in the receive shift register. This happens when addi-
tional data arrives while the FIFO is full. In this case,
the previous data in the shift register is overwritten.
Note that under this condition, the data byte in the
receive shift register is not transferred into the FIFO;
therefore, the data in the FIFO is not corrupted by the
error.
LSR BIT-2:
Logic 0 = No parity error (normal default condition).
Logic 1 = Parity error. The receive character does not
have correct parity information and is suspect. In the
FIFO mode, this error is associated with the character
at the top of the FIFO.
LSR BIT-3:
Logic 0 = No framing error (normal default condition).
Logic 1 = Framing error. The receive character did not
have a valid stop bit(s). In the FIFO mode this error is
associated with the character at the top of the FIFO.
LSR BIT-4:
Logic 0 = No break condition (normal default condi-
tion)
Logic 1 = The receiver received a break signal (RX
was a logic 0 for one character frame time). In the
FIFO mode, only one break character is loaded into
the FIFO.
LSR BIT-5:
This bit is the Transmit Holding Register Empty indi-
cator. This bit indicates that the UART is ready to
accept a new character for transmission. In addition,
this bit causes the UART to issue an interrupt to CPU
when the THR interrupt enable is set. The THR bit is
set to a logic 1 when a character is transferred from the
transmit holding register into the transmitter shift
register. The bit is reset to logic 0 concurrently with the
loading of the transmitter holding register by the CPU.
In the FIFO mode, this bit is set when the transmit
FIFO is empty; it is cleared when at least 1 byte is
written to the transmit FIFO.
LSR BIT-6:
This bit is the Transmit Empty indicator. This bit is set
to a logic 1 whenever the transmit holding register and
the transmit shift register are both empty. It is reset to
logic 0 whenever either the THR or TSR contains a
data character. In the FIFO mode this bit is set to one
whenever the transmit FIFO and transmit shift register
are both empty.
XR16C2850
25
Rev. 1.00P
LSR BIT-7:
Logic 0 = No Error (normal default condition).
Logic 1 = At least one parity error, framing error or
break indication is in the current FIFO data. This bit is
cleared when LSR register is read and there are no
subsequent errors in the FIFO.
Modem Status Register (MSR)
This register provides the current state of the control
interface signals from the modem, or other peripheral
device that the 2850 is connected to. Four bits of this
register are used to indicate the changed information.
These bits are set to a logic 1 whenever a control input
from the modem changes state. These bits are set to
a logic 0 whenever the CPU reads this register.
MSR BIT-0:
Logic 0 = No -CTS Change (normal default condition).
Logic 1 = The -CTS input to the 2850 has changed
state since the last time it was read. A modem Status
Interrupt will be generated.
MSR BIT-1:
Logic 0 = No -DSR Change (normal default condition).
Logic 1 = The -DSR input to the 2850 has changed
state since the last time it was read. A modem Status
Interrupt will be generated.
MSR BIT-2:
Logic 0 = No -RI Change (normal default condition).
Logic 1 = The -RI input to the 2850 has changed from
a logic 0 to a logic 1. A modem Status Interrupt will be
generated.
MSR BIT-3:
Logic 0 = No -CD Change (normal default condition).
Logic 1 = Indicates that the -CD input has changed
state since the last time it was read. A modem Status
Interrupt will be generated.
MSR BIT-4:
-CTS functions as hardware flow control signal input if
it is enabled via EFR bit-7. The transmit holding
register flow control is enabled/disabled by MSR bit-4.
Flow control, when enabled, allows the starting and
stopping of the transmissions based on the external
modem -CTS signal. A logic 1 at the -CTS pin will stop
2850 transmissions as soon as current character has
finished transmission.
Normally MSR bit-4 bit is the compliment of the -CTS
input. However, in the loopback mode, this bit is
equivalent to the RTS bit in the MCR register.
MSR BIT-5:
DSR (active high, logical 1). Normally this bit is the
compliment of the -DSR input. In the loopback mode,
this bit is equivalent to the DTR bit in the MCR register.
MSR BIT-6:
RI (active high, logical 1). Normally this bit is the
compliment of the -RI input. In the loopback mode this
bit is equivalent to the OP1 bit in the MCR register.
MSR BIT-7:
CD (active high, logical 1). Normally this bit is the
compliment of the -CD input. In the loopback mode
this bit is equivalent to the OP2 bit in the MCR register.
Scratchpad Register (SPR)
The XR16C2850 provides a temporary data register to
store 8 bits of user information.
Enhanced Feature Register (EFR)
Enhanced features are enabled or disabled using this
register.
Bits-0 through 4 provide single or dual character
software flow control selection. When the Xon1 and
Xon2 and/or Xoff1 and Xoff2 modes are selected (see
Table 7), the double 8-bit words are concatenated into
two sequential characters.
EFR BIT 0-3: (logic 0 or cleared is the default condi-
tion)
Combinations of software flow control can be selected
by programming these bits.
XR16C2850
26
Rev. 1.00P
Table 7, SOFTWARE FLOW CONTROL FUNCTIONS
Cont-3
Cont-2
Cont-1
Cont-0
TX, RX software flow controls
0
0
X
X
No transmit flow control
1
0
X
X
Transmit Xon1/Xoff1
0
1
X
X
Transmit Xon2/Xoff2
1
1
X
X
Transmit Xon1 and Xon2/Xoff1 and Xoff2
X
X
0
0
No receive flow control
X
X
1
0
Receiver compares Xon1/Xoff1
X
X
0
1
Receiver compares Xon2/Xoff2
1
0
1
1
Transmit Xon1/ Xoff1.
Receiver compares Xon1 and Xon2,
Xoff1 and Xoff2
0
1
1
1
Transmit Xon2/Xoff2
Receiver compares Xon1 and Xon2/Xoff1 and Xoff2
1
1
1
1
Transmit Xon1 and Xon2/Xoff1 and Xoff2
Receiver compares Xon1 and Xon2/Xoff1 and Xoff2
0
0
1
1
No transmit flow control
Receiver compares Xon1 and Xon2/Xoff1 and Xoff2
EFR BIT-5:
Logic 0 = Special Character Detect Disabled (normal
default condition).
Logic 1 = Special Character Detect Enabled. The
2850 compares each incoming receive character with
Xoff-2 data. If a match exists, the received data will be
transferred to FIFO and ISR bit-4 will be set to indicate
detection of special characters. Bit-0 in the X-registers
corresponds with the LSB bit for the receive character.
When this feature is enabled, the normal software flow
control must be disabled (EFR bits 0-3 must be set to
a logic 0).
EFR BIT-6:
Automatic RTS may be used for hardware flow control
by enabling EFR bit-6. When AUTO RTS is selected,
an interrupt will be generated when the receive FIFO
is filled to the programmed trigger level and -RTS will
go to a logic 1 at the next trigger level. -RTS will return
to a logic 0 when data is unloaded below the next lower
trigger level (Programmed trigger level -1). The state
of this register bit changes with the status of the
EFR BIT-4:
Enhanced function control bit. The content of the IER
bits 4-7, ISR bits 4-5, FCR bits 4-5, and MCR bits 5-7
can be modified and latched. After modifying any bits
in the enhanced registers, EFR bit-4 can be set to a
logic 0 to latch the new values. This feature prevents
existing software from altering or overwriting the 2850
enhanced functions.
Logic 0 = disable/latch enhanced features. IER bits 4-
7, ISR bits 4-5, FCR bits 4-5, and MCR bits 5-7 are
saved to retain the user settings, then IER bits 4-7, ISR
bits 4-5, FCR bits 4-5, and MCR bits 5-7 are initialized
to the default values shown in the Internal Resister
Table. After a reset, the IER bits 4-7, ISR bits 4-5, FCR
bits 4-5, and MCR bits 5-7 are set to a logic 0, to be
compatible with ST16C550 mode (normal default
condition).
Logic 1 = Enables the enhanced functions. When this
bit is set to a logic 1, all enhanced features of the 2850
are enabled and user settings stored during a reset will
be restored.
XR16C2850
27
Rev. 1.00P
hardware flow control. -RTS functions normally when
hardware flow control is disabled.
0 = Automatic RTS flow control is disabled (normal
default condition).
1 = Enable Automatic RTS flow control.
EFR bit-7:
Automatic CTS Flow Control.
Logic 0 = Automatic CTS flow control is disabled
(normal default condition).
Logic 1 = Enable Automatic CTS flow control. Trans-
mission will stop when -CTS goes to a logic 1. Trans-
mission will resume when the -CTS pin returns to a
logic 0.
FEATURE CONTROL REGISTER
This register controls the XR16C2850 new functions
that are not available on ST16C550 or ST16C650.
FCTR BIT 0-1:
User selectable -RTS hysterisis for hardware flow
control application. After reset, these bits are set to 0
to select the next trigger level for hardware flow
control.
FCTR
FCTR
Trigger
Bit-1
Bit-0
level
0
0
Next trigger
level
0
1
4 word+trigger level
1
0
6 word+trigger level
1
1
8 word+trigger level
FCTR BIT-2:
0 = Select RX input as encoded IrDa data.
1 = Select RX input as active high encoded IrDa data.
FCTR BIT-3:
Interrupt type select and Auto RS-485 half duplex
control.
0 = Standard ST16C550 mode. Transmitter generates
interrupt when transmit holding register is empty and
transmit shift register is shifting data out.
1 = Transmit empty interrupt. Transmit interrupt is
generated when the transmitter holding and shift
register is empty. The -RTS A/B out pins will stay high
during receive mode and will go low during transmit
mode.
FCTR BIT 4-5:
Transmit / receive trigger table select.
FCTR
FCTR
Table
Bit-5
Bit-4
0
0
Table-A (TX/RX)
0
1
Table-B (TX/RX)
1
0
Table-C (TX/RX)
1
1
Table-D (TX/RX)
FCTR BIT-6:
Register mode select.
0 = Scratch Pad register is selected as general read
and write register (ST16C550 compatible mode).
1 = FIFO count register. Number of characters in
transmit or receive holding register can be read via
scratch pad register when this bit is set.
FCTR BIT-7:
Programmable trigger register select.
0 = Receiver programmable trigger level register is
selected.
1 = Transmitter programmable trigger level register is
selected.
XR16C2850
28
Rev. 1.00P
TRIGGER LEVEL / FIFO DATA COUNT REGISTER
User programmable transmit / receive trigger level
register.
TRG BIT 0-7: Write only.
These bits are used to program desire trigger levels
that are not available in standard tables.
TRG BIT 0-7: Read only.
Transmit / receive FIFO count. Number of characters
in transmit or receive FIFO can be read via this
register.
ENHANCED MODE SELECT REGISTER
This register is accessible only when FCTR Bit-6 is set
to 1.
EMSR BIT-0: Write only
0 = Receive FIFO count register. The scratch pad
register is used to provide the receive FIFO count
when it is read.
1 = Transmit FIFO count register. The scratch pad
register is used to provide the transmit FIFO count
when it is read.
EMSR BIT-1: Write only
0 = Normal.
1 = Alternate receive - transmit FIFO count. When
EMSR Bit-0=1 and EMSR Bit=1, scratch pad register
is used to provide the receive - transmit FIFO count
when it is read every alternate read cycle. The TRG
Bit-7 will provide the FIFO count mode information,
TRG Bit-7=0 receive mode, TRG Bit-7=1 transmit
mode.
EMSR BIT 4-7:
Reserved for future use.
XR16C2850 EXTERNAL RESET CONDITIONS
REGISTERS
RESET STATE
IER
IER BITS 0-7 = logic 0
ISR
ISR BIT-0=1, ISR BITS 1-7 =
logic 0
LCR, MCR
BITS 0-7 = logic 0
LSR
LSR BITS 0-4 = logic 0,
LSR BITS 5-6 = logic 1 LSR, BIT
7 = logic 0
MSR
MSR BITS 0-3 = logic 0,
MSR BITS 4-7 = logic levels of
the input signals
FCR, EFR
BITS 0-7 = logic 0
FCTR
BITS 0-7= logic 0
EMSR
BITS 0-7 = logic 0
SIGNALS
RESET STATE
TX
Logic 1
-OP2
Logic 1
-RTS
Logic 1
-DTR
Logic 1
-RXRDY
Logic 1
-TXRDY
Logic 0
INT
Logic 0
XR16C2850
29
Rev. 1.00P
Symbol
Parameter
Limits
Limits
Units
Conditions
3.3
5.0
Min
Max
Min
Max
AC ELECTRICAL CHARACTERISTICS
T
A
=0 - 70C (-40 - +85C for Industrial grade packages), Vcc=3.3 - 5.0 V 10% unless otherwise specified.
T
1w
,T
2w
Clock pulse duration
17
17
ns
T
3w
Oscillator/Clock frequency
8
24
MHz
T
6s
Address setup time
5
0
ns
T
7d
-IOR delay from chip select
10
10
ns
T
7w
-IOR strobe width
35
25
ns
T
7h
Chip select hold time from -IOR
0
0
ns
T
9d
Read cycle delay
40
30
ns
T
12d
Delay from -IOR to data
35
25
ns
T
12h
Data disable time
25
15
ns
T
13d
-IOW delay from chip select
10
10
ns
T
13w
-IOW strobe width
40
25
ns
T
13h
Chip select hold time from -IOW
0
0
ns
T
15d
Write cycle delay
40
30
ns
T
16s
Data setup time
20
15
ns
T
16h
Data hold time
5
5
ns
T
17d
Delay from -IOW to output
50
40
ns
100 pF load
T
18d
Delay to set interrupt from MODEM
40
35
ns
100 pF load
input
T
19d
Delay to reset interrupt from -IOR
40
35
ns
100 pF load
T
20d
Delay from stop to set interrupt
1
1
Rclk
T
21d
Delay from -IOR to reset interrupt
45
40
ns
100 pF load
T
22d
Delay from stop to interrupt
45
40
ns
T
23d
Delay from initial INT reset to transmit
8
24
8
24
Rclk
start
T
24d
Delay from -IOW to reset interrupt
45
40
ns
T
25d
Delay from stop to set -RxRdy
1
1
Rclk
T
26d
Delay from -IOR to reset -RxRdy
45
40
ns
T
27d
Delay from -IOW to set -TxRdy
45
40
ns
T
28d
Delay from start to reset -TxRdy
8
8
Rclk
T
R
Reset pulse width
40
40
ns
N
Baud rate devisor
1
2
16
-1
1
2
16
-1
Rclk
XR16C2850
30
Rev. 1.00P
ABSOLUTE MAXIMUM RATINGS
Supply range
7 Volts
Voltage at any pin
GND - 0.3 V to VCC +0.3 V
Operating temperature
-40
C to +85
C
Storage temperature
-65
C to 150
C
Package dissipation
500 mW
DC ELECTRICAL CHARACTERISTICS
T
A
=0 - 70C (-40 - +85C for Industrial grade packages), Vcc=3.3 - 5.0 V 10% unless otherwise specified.
Symbol
Parameter
Limits
Limits
Units
Conditions
3.3
5.0
Min
Max
Min
Max
V
ILCK
Clock input low level
-0.3
0.6
-0.5
0.6
V
V
IHCK
Clock input high level
2.4
VCC
3.0
VCC
V
V
IL
Input low level
-0.3
0.8
-0.5
0.8
V
V
IH
Input high level
2.0
2.2
VCC
V
V
OL
Output low level on all outputs
0.4
V
I
OL
= 5 mA
V
OL
Output low level on all outputs
0.4
V
I
OL
= 4 mA
V
OH
Output high level
2.4
V
I
OH
= -5 mA
V
OH
Output high level
2.0
V
I
OH
= -1 mA
I
IL
Input leakage
10
10
A
I
CL
Clock leakage
10
10
A
I
CC
Avg power supply current
1.2
3
mA
I
SB
Avg stand by current
30
100
A
C
P
Input capacitance
5
5
pF
XR16C2850
31
Rev. 1.00P
General write timing
General read timing
A0-A2
-CSx
-IOW
D0-D7
T6s
T13w
T13d
T13h
T15d
T16s
T16h
X552-WD-2
Valid
Address
Active
Active
Data
A0-A2
-CS
-IOR
D0-D7
T6s
T7w
T7d
T7h
T9d
T12d
T12h
X552-RD-1
Active
Data
Valid
Address
Active
XR16C2850
32
Rev. 1.00P
External clock timing
Modem input/output timing
-IOW
-RTS
-DTR
-CD
-CTS
-DSR
INT
-IOR
-RI
T17d
T18d
T18d
T19d
T18d
X552-MD-1
Active
Active
Change of state
Change of state
Active
Active
Active
Change of state
Change of state
Change of state
Active
Active
T3w
T1w
T2w
EXTERNAL
CLOCK
X654-CK-1
XR16C2850
33
Rev. 1.00P
Receive timing
STOP
BIT
PARITY
BIT
DATA BITS (5-8)
D0
D1
D2
D3
D4
D5
D6
D7
5 DATA BITS
6 DATA BITS
7 DATA BITS
START
BIT
RX
NEXT
DATA
START
BIT
INT
-IOR
T20d
T21d
16 BAUD RATE CLOCK
X552-RX-1
Active
Active
XR16C2850
34
Rev. 1.00P
Receive timing in FIFO mode
Receive ready timing in none FIFO mode
STOP
BIT
PARITY
BIT
DATA BITS (5-8)
D0
D1
D2
D3
D4
D5
D6
D7
START
BIT
RX
First byte
that reaches
the trigger
level
-RXRDY
-IOR
T25d
T26d
X552-RX-3
Active
Data
Ready
Active
STOP
BIT
PARITY
BIT
DATA BITS (5-8)
D0
D1
D2
D3
D4
D5
D6
D7
START
BIT
RX
NEXT
DATA
START
BIT
-RXRDY
-IOR
T25d
T26d
X552-RX-2
Active
Data
Ready
Active
XR16C2850
35
Rev. 1.00P
Transmit timing
STOP
BIT
PARITY
BIT
DATA BITS (5-8)
D0
D1
D2
D3
D4
D5
D6
D7
5 DATA BITS
6 DATA BITS
7 DATA BITS
START
BIT
TX
NEXT
DATA
START
BIT
INT
T22d
T24d
16 BAUD RATE CLOCK
X552-TX-1
-IOW
T23d
Active
Active
Tx Ready
Active
XR16C2850
36
Rev. 1.00P
Transmit ready timing in none FIFO mode
STOP
BIT
PARITY
BIT
DATA BITS (5-8)
D0
D1
D2
D3
D4
D5
D6
D7
START
BIT
TX
NEXT
DATA
START
BIT
-TXRDY
T28d
X552-TX-2
-IOW
T27d
BYTE #1
Active
Active
Transmitter ready
Transmitter
not ready
D0-D7
XR16C2850
37
Rev. 1.00P
Transmit ready timing in FIFO mode
STOP BIT
PARITY BIT
DATA BITS (5-8)
D0
D1
D2
D3
D4
D5
D6
D7
5 DATA BITS
6 DATA BITS
7 DATA BITS
START BIT
TX
-IOW
D0-D7
-TXRDY
BYTE #128
T28d
T27d
X552-TX-3
FIFO Full
Active
XR16C2850
38
Rev. 1.00P
UART Frame
Data Bits
St
a
r
t
St
o
p
0
0
0
0
0
1
1
1 1
1
TX
IRTX
Bit Time
1/2 Bit Time
3/16 Bit Time
UART Frame
Data Bits
St
a
r
t
St
o
p
0
0
0
0
0
1
1
1 1
1
RX
IRRX
Bit Time
0-1 16x clock
delay
X650-IR-1
Infrared transmit timing
Infrared receive timing
XR16C2850
39
40
1
21
20
D
e
40 LEAD PLASTIC DUAL-IN-LINE
(600 MIL PDIP)
Rev. 1.00
SYMBOL
MIN
MAX
MIN
MAX
A
0.160
0.250
4.06
6.35
A
1
0.015
0.070
0.38
1.78
A
2
0.125
0.195
3.18
4.95
B
0.014
0.024
0.36
0.56
B
1
0.030
0.070
0.76
1.78
C
0.008
0.014
0.20
0.38
D
1.980
2.095
50.29
53.21
E
0.600
0.625
15.24
15.88
E
1
0.485
0.580
12.32
14.73
e
0.100 BSC
2.54 BSC
e
A
0.600 BSC
15.24 BSC
e
B
0.600
0.700
15.24
17.78
L
0.115
0.200
2.92
5.08
a
0
15
0
15
INCHES
MILLIMETERS
A
1
E
1
E
A
L
Seating
Plane
A
2
a
B
1
B
C
Note: The control dimension is the inch column
e
B
e
A
XR16C2850
40
44 LEAD PLASTIC LEADED CHIP CARRIER
(PLCC)
Rev. 1.00
1
D
D1
A
A
1
D
D
1
D
3
A
0.165
0.180
4.19
4.57
A
1
0.090
0.120
2.29
3.05
A
2
0.020
------.
0.51
------
B
0.013
0.021
0.33
0.53
B
1
0.026
0.032
0.66
0.81
C
0.008
0.013
0.19
0.32
D
0.685
0.695
17.40
17.65
D
1
0.650
0.656
16.51
16.66
D
2
0.590
0.630
14.99
16.00
D
3
0.500 typ.
12.70 typ.
e
0.050 BSC
1.27 BSC
H1
0.042
0.056
1.07
1.42
H2
0.042
0.048
1.07
1.22
R
0.025
0.045
0.64
1.14
SYMBOL
MIN
MAX
MIN
MAX
INCHES
MILLIMETERS
B
A
2
B
1
e
Seating Plane
D
2
2
44
Note: The control dimension is the inch column
D
3
45 x H2
45 x H1
C
R
XR16C2850
41
48 LEAD THIN QUAD FLAT PACK
(7 x 7 x 1.0 mm, TQFP)
Rev. 1.00
36
25
24
13
1
12
37
48
D
D
1
D
D
1
B
e
a
A
2
A
1
A
Seating Plane
A
0.039
0.047
1.00
1.20
A
1
0.002
0.006
0.05
0.15
A
2
0.037
0.041
0.95
1.05
B
0.007
0.011
0.17
0.27
C
0.004
0.008
0.09
0.20
D
0.346
0.362
8.80
9.20
D
1
0.272
0.280
6.90
7.10
e
0.020 BSC
0.50 BSC
L
0.018
0.030
0.45
0.75
a
0
7
0
7
SYMBOL
MIN
MAX
MIN
MAX
INCHES
MILLIMETERS
Note: The control dimension is the millimeter column
L
C
XR16C2850
42
Notes
XR16C2850
43
Notes
XR16C2850
44
NOTICE
EXAR Corporation reserves the right to make changes to the products contained in this publication in order to im-
prove design, performance or reliability. EXAR Corporation assumes no responsibility for the use of any circuits de-
scribed herein, conveys no license under any patent or other right, and makes no representation that the circuits are
free of patent infringement. Charts and schedules contained here in are only for illustration purposes and may vary
depending upon a user's specific application. While the information in this publication has been carefully checked;
no responsibility, however, is assumed for inaccuracies.
EXAR Corporation does not recommend the use of any of its products in life support applications where the failure or
malfunction of the product can reasonably be expected to cause failure of the life support system or to significantly
affect its safety or effectiveness. Products are not authorized for use in such applications unless EXAR Corporation
receives, in writing, assurances to its satisfaction that: (a) the risk of injury or damage has been minimized; (b) the
user assumes all such risks; (c) potential liability of EXAR Corporation is adequately protected under the circum-
stances.
Copyright 1998 EXAR Corporation
Datasheet June 1998
Reproduction, in part or whole, without the prior written consent of EXAR Corporation is prohibited.